scholarly journals Optimization Technique Inspired Load Frequency Controller for Multi Area Power System with Renewable Energy Source

2021 ◽  
Vol 850 (1) ◽  
pp. 012017
Author(s):  
J Shri Saranyaa ◽  
A Peer Fathima ◽  
Asutosh Mishra ◽  
Rushali Ghosh ◽  
Shalmali Das

Abstract Modern day scenario has an increasing power demand due to the growing development which indeed increases the load on the generation which might cause turbulence in the system and may bounce out of stability. The governor itself can’t handle such frequent load changes and adjust the generation amount to keep the frequency between the margins. This paper proposes an approach towards such predicament to incorporate an optimization method in order to ensure stability of the system despite the drastic changes in demand. Load frequency control is a control method for maintaining the frequency of the system during the change in demand. Use of controllers has proven to be effective in controlling the frequency deviations in the power systems and the response of the controller is further improved using optimization technique for better stability. The PID controller tuned by Particle Swarm Optimization is employed in multi-area system which reduces the time response by a considerable amount and the deviation settles much quicker despite the rapid load changes. The proposed controller is executed further for renewable energy sources connected to the individual areas and demonstration proves that the optimized controller is efficient enough in handling the frequency deviations when wind and solar with sunlight penetration is incorporated.

Author(s):  
Mohamed Abdul Raouf Shafei ◽  
Ahmed Nabil Abd Alzaher ◽  
Doaa Khalil Ibrahim

The foremost aims the Load Frequency Control (LFC) is to maintain the frequency at nominal value and minimize the unscheduled tie line power flow between different control areas. The penetration of renewable energy sources into the grid is a recent challenge to the power system operators due to their different modelling rather than conventional units. In this paper, enhancing load frequency control of multi-area multi-sources power system including renewable units system with nonlinearities is proposed using a new application of proportional–integral–derivative controller with proportional controller in the inner feedback loop, which is called as PID-P controller. To investigate the performance of the proposed controller, a thermal with reheater, hydro, wind and diesel power generation units with physical constraints such as governor dead band, generation rate constraint, time delay and boiler dynamics are considered. The proposed controller parameters are optimized using different heuristic optimization techniques such: Linearized Biogeography-Based Optimization technique, Biogeography-Based Optimization technique and Genetic Algorithm. The ability of the system to handle the large variation in load conditions, time delay, participation factors, and system parameters has been verified comprehensively.


2020 ◽  
Vol 6 ◽  
pp. 1597-1603
Author(s):  
Lei Liu ◽  
Tomonobu Senjyu ◽  
Takeyoshi Kato ◽  
Abdul Motin Howlader ◽  
Paras Mandal ◽  
...  

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 573
Author(s):  
Mohamed Mokhtar ◽  
Mostafa I. Marei ◽  
Mariam A. Sameh ◽  
Mahmoud A. Attia

The frequency of power systems is very sensitive to load variations. Additionally, with the increased penetration of renewable energy sources in electrical grids, stabilizing the system frequency becomes more challenging. Therefore, Load Frequency Control (LFC) is used to keep the frequency within its acceptable limits. In this paper, an adaptive controller is proposed to enhance the system performance under load variations. Moreover, the proposed controller overcomes the disturbances resulting from the natural operation of the renewable energy sources such as Wave Energy Conversion System (WECS) and Photovoltaic (PV) system. The superiority of the proposed controller compared to the classical LFC schemes is that it has auto tuned parameters. The validation of the proposed controller is carried out through four case studies. The first case study is dedicated to a two-area LFC system under load variations. The WECS is considered as a disturbance for the second case study. Moreover, to demonstrate the superiority of the proposed controller, the dynamic performance is compared with previous work based on an optimized controller in the third case study. Finally in the fourth case study, a sensitivity analysis is carried out through parameters variations in the nonlinear PV-thermal hybrid system. The novel application of the adaptive controller into the LFC leads to enhance the system performance under disturbance of different sources of renewable energy. Moreover, a robustness test is presented to validate the reliability of the proposed controller.


1988 ◽  
Vol 21 (11) ◽  
pp. 387-393 ◽  
Author(s):  
H. Sasaki ◽  
H. Yorino ◽  
T. Suizu ◽  
S. Yurino ◽  
R. Yokoyama ◽  
...  

Author(s):  
Tarakanta Jena ◽  
Manoj Kumar Debnath ◽  
Smaran Kumar Sanyal

A newly adopted optimization technique known as sine-cosine algorithm (SCA) is suggested in this research article to tune the gains of Fuzzy-PID controller along with a derivative filter (Fuzzy-PIDF) of a hybrid interconnected system for the Load Frequency Control (LFC). The scrutinized multi-generation system considers hydro, gas and thermal sources in all areas of the dual area power system integrated with UPFC (unified power flow controller) and SMES (Super-conducting magnetic energy storage) units. The preeminence of the offered Fuzzy-PIDF controller is recognized over Fuzzy-PID controller by comparing their dynamic performance indices concerning minimum undershoot, settling time and also peak overshoot. Finally, the sensitiveness and sturdiness of the recommended control method are proved by altering the parameters of the system from their nominal values and by the implementation of random loading in the system.