scholarly journals Thermal performance of double-pass counter flow and double-parallel flow solar air heater with V-grooved absorber plate

2021 ◽  
Vol 1076 (1) ◽  
pp. 012081
Author(s):  
Ali M. Rasham ◽  
Basim A. R. Al-Bakri
2018 ◽  
Author(s):  
D.V.N. Lakshmi ◽  
Palanisamy Muthukumar ◽  
Dr.Apurba Layek ◽  
Abhimanyu Kumar Singh ◽  
Sushoban Das

2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Satyender Singh ◽  
Prashant Dhiman

Thermal performance of a single-pass single-glass cover solar air heater consisting of semicircular absorber plate finned with rectangular longitudinal fins is investigated. The analysis is carried out for different hydraulic diameters, which were obtained by varying the diameter of the duct from 0.3–0.5 m. One to five numbers of fins are considered. Reynolds number ranges from 1600–4300. Analytical solutions for energy balance equations of different elements and duct flow of the solar air heater are presented; results are compared with finite-volume methodology based numerical solutions obtained from ansys fluent commercial software, and a fairly good agreement is achieved. Moreover, analysis is extended to check the effect of double-glass cover and the recycle of the exiting air. Results revealed that the use of double-glass cover and recycle operation improves the thermal performance of solar air heater.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Raheleh Nowzari ◽  
Hasan Saygin ◽  
L.B.Y. Aldabbagh

Abstract An experimental study was conducted to evaluate the thermal efficiency of a modified solar air heater. In the current design, air enters the collector through holes in front glass, passes through mesh layers, and exits at the backside of the air heater. A centrifugal fan was used to circulate air through the system. The design offers low construction costs and less solar radiation reflected from the collector. The modified collector was examined with various bed heights (30, 50, and 70 mm) and different mass flowrates of air varying from 0.011 kg/(s m2) to 0.043 kg/(s m2). The results showed that a counter flow collector with pierced cover had 5.6–9.7% higher efficiency than the single-pass one. The average efficiencies of the current design collector were found to be 55.2%, 44.6%, and 39.7% for the single-pass and 60.8%, 50.9% and 45.4% for the double-pass collector at 30, 50, and 70 mm bed heights and airflow rate of 0.043 kg/(s m2), respectively. The thermohydraulic efficiency, temperature difference, and perforated cover surface temperature were analyzed at each test and their effects on the system performance were evaluated. The highest amount of pressure drop through the collector was measured in the collector with a 70-mm bed height and a maximum air flowrate.


Sign in / Sign up

Export Citation Format

Share Document