scholarly journals Influence of Various Tooth Shape Topology for Single-Phase Permanent Magnet Flux Switching Machine

2021 ◽  
Vol 1127 (1) ◽  
pp. 012027
Author(s):  
Laili Iwani Jusoh ◽  
Erwan Sulaiman ◽  
Md Zarafi Ahmad ◽  
Irfan Ali Soomro ◽  
Hassan Ali Soomro
2019 ◽  
Vol 81 (4) ◽  
Author(s):  
Hari Prasetijo ◽  
Winasis Winasis ◽  
Priswanto Priswanto ◽  
Dadan Hermawan

This study aims to observe the influence of the changing stator dimension on the air gap magnetic flux density (Bg) in the design of a single-phase radial flux permanent magnet generator (RFPMG). The changes in stator dimension were carried out by using three different wire diameters as stator wire, namely, AWG 14 (d = 1.63 mm), AWG 15 (d = 1.45 mm) and AWG 16 (d = 1.29 mm). The dimension of the width of the stator teeth (Wts) was fixed such that a larger stator wire diameter will require a larger stator outside diameter (Dso). By fixing the dimensions of the rotor, permanent magnet, air gap (lg) and stator inner diameter, the magnitude of the magnetic flux density in the air gap (Bg) can be determined. This flux density was used to calculate the phase back electromotive force (Eph). The terminal phase voltage (V∅) was determined after calculating the stator wire impedance (Z) with a constant current of 3.63 A. The study method was conducted by determining the design parameters, calculating the design variables, designing the generator dimensions using AutoCad and determining the magnetic flux density using FEMM simulation.  The results show that the magnetic flux density in the air gap and the phase back emf Eph slightly decrease with increasing stator dimension because of increasing reluctance. However, the voltage drop is more dominant when the stator coil wire diameter is smaller. Thus, a larger diameter of the stator wire would allow terminal phase voltage (V∅) to become slightly larger. With a stator wire diameter of 1.29, 1.45 and 1.63 mm, the impedance values of the stator wire (Z) were 9.52746, 9.23581 and 9.06421 Ω and the terminal phase voltages (V∅) were 220.73, 221.57 and 222.80 V, respectively. Increasing the power capacity (S) in the RFPMG design by increasing the diameter (d) of the stator wire will cause a significant increase in the percentage of the stator maximum current carrying capacity wire but the decrease in stator wire impedance is not significant. Thus, it will reduce the phase terminal voltage (V∅) from its nominal value.


2004 ◽  
Vol 40 (2) ◽  
pp. 516-525 ◽  
Author(s):  
T.J.E. Miller ◽  
M. Popescu ◽  
C. Cossar ◽  
M. McGilp ◽  
G. Strappazzon ◽  
...  

2020 ◽  
Vol 2 (2) ◽  
pp. 28-31
Author(s):  
Agus Nur Hidayat ◽  
Suyitno ◽  
Daryanto

The purpose of this research is to know to know the influence of stator coil shape to performance (induced voltage and output power) of single phase axial flux permanent magnet generator. The method used is an experimental method. The population in this study is a unit of single phase axial flux permanent magnet generator. The sample in this study is the stator coil. Experiments were carried out by testing the performance of a single-phase axial flux permanent magnet generator in each variation the number of coil windings which had the 90 turns, 120 turns, and 350 turns. Experiments were carried out with no -load testing and with a resitive load that used 30 Watt incandescent lamps. The conclusion of this study shows that there is an influence from the number of coil windings on the performance (induced voltage and output power) of the generator. From three variations of the stator coil that used as sample, the highest performance is shown by the single phase axial flux permanent magnet generator which used the highest number of coil stator turns. The more number of turns, the better the performance of a single-phase axial flux permanent magnet generator. Abstrak Tujuan dari penelitian ini adalah untuk mengetahui pengaruh jumlah lilitan kumparan stator terhadap kinerja generator fluks aksial satu fasa yang berupa tegangan induksi dan daya listrik yang dihasilkan. Metode yang digunakan adalah metode eksperimen. Populasi pada penelitian ini ialah satu unit generator magnet permanen fluks aksial satu fasa. Sampel pada penelitian ini ialah kumparan stator. Eksperimen dilakukan dengan menguji kinerja generator magnet permanen fluks aksial satu fasa pada setiap variasi jumlah lilitan kumparan stator 90 lilitan, 120 lilitan, dan 350 lilitan. Ekperimen dilakukan dengan pengujian tanpa beban dan dengan beban resitif berupa lampu pijar 30 Watt. Kesimpulan pada penelitian ini menunjukkan bahwa adanya pengaruh jumlah lilitan kumparan stator terhadap kinerja generator yang berupa tegangan induksi dan daya listrik keluaran. Dari ketiga variasi sampel kumparan stator, kinerja tertinggi ditunjukkan oleh generator magnet permanen fluks aksial satu fasa yang menggunakan jumlah lilitan kumparan stator terbanyak. Semakin banyak jumlah lilitan, semakin baik kinerja generator magnet permanen fluks aksial satu fasa.


Sign in / Sign up

Export Citation Format

Share Document