scholarly journals Design and simulation of front end power converter for a microgrid with fuel cells and solar power sources

Author(s):  
Chetankumar Jeevargi ◽  
Anuj Lodhi ◽  
Allu Sateeshkumar ◽  
D Elangovan ◽  
G Arunkumar
2021 ◽  
Vol 13 (9) ◽  
pp. 4736
Author(s):  
Fan Liu ◽  
Chuancheng Duan

Solid oxide fuel cells (SOFCs) are promising and rugged solid-state power sources that can directly and electrochemically convert the chemical energy into electric power. Direct-hydrocarbon SOFCs eliminate the external reformers; thus, the system is significantly simplified and the capital cost is reduced. SOFCs comprise the cathode, electrolyte, and anode, of which the anode is of paramount importance as its catalytic activity and chemical stability are key to direct-hydrocarbon SOFCs. The conventional SOFC anode is composed of a Ni-based metallic phase that conducts electrons, and an oxygen-ion conducting oxide, such as yttria-stabilized zirconia (YSZ), which exhibits an ionic conductivity of 10−3–10−2 S cm−1 at 700 °C. Although YSZ-based SOFCs are being commercialized, YSZ-Ni anodes are still suffering from carbon deposition (coking) and sulfur poisoning, ensuing performance degradation. Furthermore, the high operating temperatures (>700 °C) also pose challenges to the system compatibility, leading to poor long-term durability. To reduce operating temperatures of SOFCs, intermediate-temperature proton-conducting SOFCs (P-SOFCs) are being developed as alternatives, which give rise to superior power densities, coking and sulfur tolerance, and durability. Due to these advances, there are growing efforts to implement proton-conducting oxides to improve durability of direct-hydrocarbon SOFCs. However, so far, there is no review article that focuses on direct-hydrocarbon P-SOFCs. This concise review aims to first introduce the fundamentals of direct-hydrocarbon P-SOFCs and unique surface properties of proton-conducting oxides, then summarize the most up-to-date achievements as well as current challenges of P-SOFCs. Finally, strategies to overcome those challenges are suggested to advance the development of direct-hydrocarbon SOFCs.


2018 ◽  
Vol MA2018-01 (32) ◽  
pp. 1992-1992
Author(s):  
Mohamed El Hannach ◽  
Ka Hung Wong ◽  
Yadvinder Singh ◽  
Narinder Singh Khattra ◽  
Erik Kjeang

The hydrogen fuel cell is a promising technology that supports the development of sustainable energy systems and zero emission vehicles. One of the key technical challenges for the use of fuel cells in the transportation sector is the high durability requirements 1–3. One of the key components that control the overall life time of a hydrogen fuel cell is the ionomer membrane that conducts the protons and allows the separation between the anode and the cathode. During fuel cell operation, the membrane is subjected to two categories of degradation: mechanical and chemical. These degradations lead to reduction in the performance, crossover of reactants between anode and cathode and ultimately total failure of the fuel cell. The mechanical degradation occurs when the membrane swells and shrinks under the variation of the local hydration level. This leads to fatigue of the ionomer structure and ultimately irreversible damage. However, under pure mechanical degradation the damage takes a very long time to occur 4,5. Sadeghi et al. 5 observed failure of the membrane after 20,000 of accelerated mechanical stress testing. This translates into a longer lifetime in comparison to what is observed in field operation 6. The chemical degradation on the other hand is caused by the presence of harmful chemicals such as OH radicals that attack the side chains and the main chains of the ionomer 7,8. Such attacks weaken the structural integrity of the membrane and make it prone to severe mechanical damage. Hence understanding the effect of combining both categories of membrane degradation is the key to accurate prediction of the time to failure of the fuel cell. In this work we propose a novel model that represents accurately the structural properties of the membrane and couples the chemical and the mechanical degradations to estimate when the ultimate failure is initiated. The model is based on a network of agglomerated fibrils corresponding to the basic building block of the membrane structure 9–11. The mechanical and chemical properties are defined for each fibril and probability functions are used to evaluate the likelihood of a fibril to break under certain operating conditions. The description of the fundamentals behind the approach will be presented. Two set of simulations will be presented and discussed. The first one corresponding to standard testing scenarios that were used to validate the model. The second set of results will highlight the impact of coupling both degradation mechanisms on the estimation of the failure initiation time. The main strengths of the model and the future development will be discussed as well. T. Sinigaglia, F. Lewiski, M. E. Santos Martins, and J. C. Mairesse Siluk, Int. J. Hydrogen Energy, 42, 24597–24611 (2017). T. Jahnke et al., J. Power Sources, 304, 207–233 (2016). P. Ahmadi and E. Kjeang, Int. J. Energy Res., 714–727 (2016). X. Huang et al., J. Polym. Sci. Part B Polym. Phys., 44, 2346–2357 (2006). A. Sadeghi Alavijeh et al., J. Electrochem. Soc., 162, F1461–F1469 (2015). N. Macauley et al., J. Power Sources, 336, 240–250 (2016). K. H. Wong and E. Kjeang, J. Electrochem. Soc., 161, F823–F832 (2014). K. H. Wong and E. Kjeang, ChemSusChem, 8, 1072–1082 (2015). P.-É. A. Melchy and M. H. Eikerling, J. Phys. Condens. Matter, 27, 325103–6 (2015). J. A. Elliott et al., Soft Matter, 7, 6820 (2011). L. Rubatat, G. Gebel, and O. Diat, Macromolecules, 37, 7772–7783 (2004).


Author(s):  
Sang-Yeop Lee ◽  
In-Gyu Min ◽  
Hyoung-Juhn Kim ◽  
Suk Woo Nam ◽  
Jaeyoung Lee ◽  
...  

Due to the advantage of fuel cells over secondary batteries such as long operation time, many efforts were executed in order to use fuel cells as main power sources of small electronic devices such as laptop computers and mobile phones. For the same reason, fuel cells are promising power sources for the hazardous mission robots. Fuel cells are able to increase their radius action through extension of operation time. Despite this advantage, there still exist technical barriers such as increasing power density, efficient hydrogen storage, and fast startup of the power system. First, in order to increase power density, the united stack including proton exchange membrane fuel cells (PEMFC) and membrane humidifying cells were developed. Also, the hydrogen generating system using NaBH4 solution was employed to store hydrogen effectively. In addition, to shorten start-up time, hybrid control of PEMFC and Li-ion battery was adopted. The approaches mentioned above were evaluated. The developed PEMFC/humidifier stack showed high performance. As compared with full humidification condition by external humidifiers, the performance decrease was only 1% even though hydrogen was not humidified and air was partially humidified. Besides, by integrating the PEMFC and the humidifier into a single stack, considerable space for tubing between them was saved. Also, the hydrogen generator operated well with the PEMFC system and allowed for effective fuel storing and refueling. In addition, due to the efficient hybrid control of PEMFC and battery, start-up time was significantly shortened and capacity of PEMFC was reduced, resulting in compactness of the power system. In conclusion, a 600 W PEMFC power system was developed and successfully operated with the robot. Through development and evaluation of the PEMFC power system, the possibility of PEMFC as a novel power source for the hazardous mission robot was verified.


2018 ◽  
Vol 96 ◽  
pp. 181-197 ◽  
Author(s):  
Weng Cheong Tan ◽  
Lip Huat Saw ◽  
Hui San Thiam ◽  
Jin Xuan ◽  
Zuansi Cai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document