scholarly journals Study of a phase-to-ground fault on a 400 kV overhead transmission line

Author(s):  
A Iagăr ◽  
G N Popa ◽  
C M Diniş
Author(s):  
Ali I. El Gayar ◽  
Zulkurnain Abdul-Malek

The purpose of this research is to investigate the severity of voltages induced on gas pipeline installed in parallel to a 115 kV overhead transmission line. The overhead transmission line (OHTL) is configured as a single-circuit. One of the phases exposed to single phase to ground fault. Transmission of high voltage along the same right of way (ROW) with metallic conductor may possibly introduce interference on metallic conductors such as gas pipeline (GPL) due to power frequency voltage as well as due to phase faults and switching phenomena. Two main approaches were used to compute the induced voltages, namely the method of moment (MOM), which is based on electromagnetic field theory, and circuit based method. The simulation considers the length of OHTL and GPL are 30 km and 10km respectively. The pipeline buried at 1 m underground in homogenous earth structure with various soil resistivites ranged from 10 to 1000 Ω-m. The transmission line consists of 150 towers and 200 m span length. The separation distance between the GPL and OHTL is varied from 5 to 100 m. The phase to ground fault current changed from 0.5 to 10 kA. Several observation points are made throughout the corridor, to examinant the induced voltages at different locations. The result show that, the soil resistivity, separation distance, and fault current had significant effect on pipeline induced voltage. In case of the observation points lying on the soil or on the outer surface of the pipeline coating, the induced voltage increased, when the soil resistivity increase, as expected. In case of the observation points placed inside the pipeline metal, and the pipeline is well coated, the induced voltage will decreased, when the soil resistivity increase.


Author(s):  
Ali I. El Gayar ◽  
Zulkurnain Abdul-Malek

The purpose of this research is to investigate the severity of voltages induced on gas pipeline installed in parallel to a 115 kV overhead transmission line. The overhead transmission line (OHTL) is configured as a single-circuit. One of the phases exposed to single phase to ground fault. Transmission of high voltage along the same right of way (ROW) with metallic conductor may possibly introduce interference on metallic conductors such as gas pipeline (GPL) due to power frequency voltage as well as due to phase faults and switching phenomena. Two main approaches were used to compute the induced voltages, namely the method of moment (MOM), which is based on electromagnetic field theory, and circuit based method. The simulation considers the length of OHTL and GPL are 30 km and 10km respectively. The pipeline buried at 1 m underground in homogenous earth structure with various soil resistivites ranged from 10 to 1000 Ω-m. The transmission line consists of 150 towers and 200 m span length. The separation distance between the GPL and OHTL is varied from 5 to 100 m. The phase to ground fault current changed from 0.5 to 10 kA. Several observation points are made throughout the corridor, to examinant the induced voltages at different locations. The result show that, the soil resistivity, separation distance, and fault current had significant effect on pipeline induced voltage. In case of the observation points lying on the soil or on the outer surface of the pipeline coating, the induced voltage increased, when the soil resistivity increase, as expected. In case of the observation points placed inside the pipeline metal, and the pipeline is well coated, the induced voltage will decreased, when the soil resistivity increase.


2020 ◽  
Vol 216 ◽  
pp. 01043
Author(s):  
Minullin Renat ◽  
Piskovatsky Yuri ◽  
Kasimov Vasil

The simulation model of the overhead transmission line channel implemented in PSCAD software allowing researches of location signal propagation via overhead lines of the distribution networks 6–35 kV under conditions of single phase-to-ground fault is considered. The model reflectograms are compared with their appropriate experimental reflectograms registered under the laboratory and field conditions for the overhead lines during simulation of various types of the single phase-to-ground faults.


2012 ◽  
Vol 610-613 ◽  
pp. 2813-2818
Author(s):  
Xian Long Lu ◽  
Zeng Zhen Qian

This paper presents the concept and the fundamental issues and the development on the environmental geotechnology in transmission lines foundation engineering. Namely, environmental geotechnology and theory is to study the restriction effects of environment on the transmission line routes, foundation selection and reliability, to predict the results of transmission line foundation construction on the environment, and to study on countermeasures of environmental protection in transmission foundation engineering. And then, from the above three aspects, the design method combined strength and displacement for tower foundation, the selection on foundation types and technical scheme for transmission line tower, and the countermeasures for soil and water conservation, the author introduces the development and practice of environmental geotechnology for transmission lines foundation engineering in China.