Evaluation of the algorithms utilised to diagnose keratoconus for the Corvis ST

Author(s):  
Robert Koprowski
Keyword(s):  
2017 ◽  
Vol 29 (3) ◽  
pp. 175-181 ◽  
Author(s):  
Roghiyeh Elham ◽  
Ebrahim Jafarzadehpur ◽  
Hassan Hashemi ◽  
Kazem Amanzadeh ◽  
Fereshteh Shokrollahzadeh ◽  
...  

2021 ◽  
pp. 112067212110637
Author(s):  
Victor A Augustin ◽  
Hyeck-Soo Son ◽  
Isabella Baur ◽  
Ling Zhao ◽  
Gerd U Auffarth ◽  
...  

Purpose To analyze the tomographically non-affected second eyes of keratoconus patients using the Corvis ST to detect any biomechanical abnormalities or subclinical keratoconus. Methods In this retrospective, single-center, consecutive case series 244 eyes of 122 keratoconus patients were analyzed between November 2020 and February 2021. Fourteen fellow eyes fulfilled the inclusion criteria and showed no clinical or tomographic signs of keratoconus. Main outcome measures included best-corrected visual acuity, tomographic and biomechanical analyses using Scheimpflug imaging: Pentacam and Corvis ST (Oculus, Wetzlar, Germany). Tomographic analyses included anterior and posterior simulated keratometry, K-Max, central corneal thickness, thinnest corneal thickness, Belin/Ambrosio Ectasia Display, and the ABCD grading system. For biomechanical analyses, the corneal biomechanical index (CBI) and tomographic biomechanical index were used. Results The mean best-corrected visual acuity was 0.01 ± 0.10 logMAR. Mean K-Max was 43.79 ± 1.12 D, mean central corneal thickness 529 ± 25 µm, mean thinnest corneal thickness 524 ± 23 µm, and mean Belin/Ambrosio Ectasia Display 1.0 ± 0.32. The mean CBI was 0.30 ± 0.21. Regular CBI values were found in six of 14 patients. The mean tomographic biomechanical index was 0.47 ± 0.22 with regular values observed in only two of 14 patients. No signs of tomographic or biomechanical abnormalities were shown in only one of 14 keratoconus fellow eyes, with regular ABCD, Belin/Ambrosio Ectasia Display, CBI and tomographic biomechanical index values. Conclusions Tomographically normal fellow eyes of keratoconus patients are rare. In these cases, a biomechanical analysis of the cornea may help detect a subclinical keratoconus. The tomographic biomechanical index was the most sensitive index to verify a mild ectasia.


Author(s):  
E.V. Boiko ◽  
◽  
E.S. Togo ◽  
I.B. Litvin ◽  
A.B. Kachanov ◽  
...  

Purpose. The aim of the study is to investigate the biomechanical properties of the cornea before and after FemtoLASIK in patients with myopia. Material and methods. 24 patients (42 eyes) underwent refractive vision correction using the FemtoLASIK method. The Oculus CORVIS ST ® device (Oculus, Germany) was used to assess the biomechanical properties of the cornea. Results. A statistically significant decrease in the rigidity and strength of the cornea was noted after keratorefractive surgery. Conclusion. Refractive surgery using FemtoLASIK technology leads to a decrease in the rigidity of the cornea, and therefore to a reduction in its framework properties. Key words: refractive surgery, FemtoLASIK, myopia, laser correction, biomechanical properties of the cornea, Oculus CORVIS ST ®.


Author(s):  
B.E. Malugin ◽  
◽  
E.G. Solodkova ◽  
S.V. Balalin ◽  
V.S. Kulikov ◽  
...  

Purpose. To make a comparative analysis of topographic, tomographic and biomechanical values, measured by Pentacam HR and Corvis ST, in healthy multirefractive cohort versus patients with keratectasia of various severity. Material and methods. The prospective study comprised 237 patients aged from 18 to 47 years, subdivided into three groups. The first group included 174 healthy persons with various refraction (174 eyes). The second and the third group embraced 63 patients with keratoconus: 36 patients (36 eyes) with keratoconus of the I degree and 27 eyes with keratoconus of the II and III degrees. Besides the conventional comprehensive ocular examination the following studies were performed in all the patients: evaluation of topographic, tomographic and biomechanical corneal properties with application of Pentacam HR and Corvis ST (OCULUS Optikgerate GmbH; Wetzlar, Germany). Results. It was revealed that the following biomechanical values, assessed by means of Pentacam HR and Corvis ST, exhibited statistically significant changes (p<0,001) in all degrees of ketatoconus: a relative corneal thickness by Ambrosio, inverted radius of applanation curvature (IntRadius), DA Ratio Coefficient, values of corneal rigidity – SP-A 1 and SSI. Conclusion. The detected parameters may be applied as indicators, allowing to evaluate corneal biomechanics, to define early features of ectatic process, to assess effectiveness of the performed corneal collagen crosslinking and intralamellar keratoplasty with implantation of corneal segments. Key words: keratoconus, corneal biomechanics, pachymetry, index of pachymetric progression, corneal viscoelasticity.


2022 ◽  
Vol 11 (1) ◽  
pp. 261
Author(s):  
Agnieszka Boszczyk ◽  
Henryk Kasprzak ◽  
Joanna Przeździecka-Dołyk

Background: The process of rapid propagation of the corneal deformation in air puff tonometer depends not only on intraocular pressure, but also on the biomechanical properties of the cornea and anterior eye. One of the biomechanical properties of the cornea is viscoelasticity, which is the most visible in its high-speed deformations. It seems reasonable to link the corneal viscoelasticity parameter to two moments of the highest speed of corneal deformations, when the cornea buckles. The aim of this work is to present a method of determining the time and place of occurrence of corneal buckling, examine spatial and temporal dependencies between two corneal applanations and bucklings in the Corvis ST tonometer, and correlate these dependencies with corneal viscoelastic properties. Methods: Images of the horizontal cross section of the Corvis ST deformed cornea from the air puff tonometer Corvis ST were used. 14 volunteers participated in the study, each of them had one eye measured eight times. Mutual changes in the profile slopes of the deformed corneas were numerically determined. They describe pure corneal deformation, eliminating the influence of rotation, and displacement of the entire eyeball. For each point in the central area of the corneal profile, the maximum velocities of mutual slope changes accompanying the applanations were estimated. The times of their occurrence were adopted as buckling times. Results: The propagation of buckling along the corneal profile is presented, as well as the repeatability and mutual correlations between the buckling parameters and intraocular pressure. Based on the relationship between them, a new parameter describing corneal hysteresis: Corvis Viscoelasticity (CVE) is introduced. It is characterized by high repeatability: ICC = 0.82 (0.69–0.93 CI) and low and insignificant correlation with intraocular pressure: r = 0.25 (p-value = 0.38). Conclusion: The results show for the first time how to measure the corneal buckling and viscoelastic effects with Corvis ST. CVE is a new proposed biomechanical parameter related to the viscoelastic properties of the cornea, which has high repeatability for the examined subject. The distribution of its values is planned to be tested on different groups of patients in order to investigate its clinical applicability.


Author(s):  
Mohammad-Reza Sedaghat ◽  
Hamed Momeni-Moghaddam ◽  
Abbas Azimi ◽  
Zohreh Fakhimi ◽  
Mohammed Ziaei ◽  
...  

Purpose: To investigate corneal biomechanical response parameters in varying degrees of myopia and their correlation with corneal geometrical parameters and axial length.Methods: In this prospective cross-sectional study, 172 eyes of 172 subjects, the severity degree of myopia was categorized into mild, moderate, severe, and extreme myopia. Cycloplegic refraction, corneal tomography using Pentacam HR, corneal biomechanical assessment using Corvis ST and Ocular Response Analyser (ORA), and ocular biometry using IOLMaster 700 were performed for all subjects. A general linear model was used to compare biomechanical parameters in various degrees of myopia, while central corneal thickness (CCT) and biomechanically corrected intraocular pressure (bIOP) were considered as covariates. Multiple linear regression was used to investigate the relationship between corneal biomechanical parameters with spherical equivalent (SE), axial length (AXL), bIOP, mean keratometry (Mean KR), and CCT.Results: Corneal biomechanical parameters assessed by Corvis ST that showed significant differences among the groups were second applanation length (AL2, p = 0.035), highest concavity radius (HCR, p &lt; 0.001), deformation amplitude (DA, p &lt; 0.001), peak distance (PD, p = 0.022), integrated inverse radius (IR, p &lt; 0.001) and DA ratio (DAR, p = 0.004), while there were no significant differences in the means of pressure-derived parameters of ORA between groups. Multiple regression analysis showed all parameters of Corvis ST have significant relationships with level of myopia (SE, AXL, Mean KR), except AL1 and AL2. Significant biomechanical parameters showed progressive reduction in corneal stiffness with increasing myopia (either with greater negative SE or greater AXL), independent of IOP and CCT. Also, corneal hysteresis (CH) or ability to dissipate energy from the ORA decreased with increasing level of myopia.Conclusions: Dynamic corneal response assessed by Corvis ST shows evidence of biomechanical changes consistent with decreasing stiffness with increasing levels of myopia in multiple parameters. The strongest correlations were with highest concavity parameters where the sclera influence is maximal.


2020 ◽  
Author(s):  
Na Wu ◽  
Yuhong Chen ◽  
Yaping Yang ◽  
Xinghuai Sun

Abstract Background: To investigate the corneal biomechanical changes in primary open angle glaucoma (POAG) patients treated with long-term prostaglandin analogue (PGA). Methods: 111 newly diagnosed POAG patients, including 43 high tension glaucoma (HTG) and 68 normal tension glaucoma (NTG), were measured by Corvis ST to obtain intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanical parameters at baseline and at each follow-up visit after initiation of PGA treatment. The follow-up measurements were analyzed by the generalized estimate equation model with an exchangeable correlation structure. Restricted cubic spline was employed to estimate the dose-response relation between follow-up time and corneal biomechanics.Results: The mean follow-up time was 10.3 ± 7.02 months. Deformation amplitude (β=-0.0015, P=0.016), the first applanation velocity (AV1, β=-0.0004, P=0.00058) decreased and the first applanation time (AT1, β=0.0089, P<0.000001) increased statistically significantly with PGA therapy over time after adjusting for age, gender, axial length, corneal curvature, IOP and CCT. In addition, AT1 was lower (7.2950 ± 0.2707 in NTG and 7.5889 ± 0.2873 in HTG, P=0.00011) and AV1 was greater (0.1478 ± 0.0187 in NTG and 0.1314 ± 0.0191 in HTG, P=0.00002) in NTG than in HTG after adjusting for confounding factors.Conclusions: Chronic use of PGA probably influences the corneal biomechanical properties directly, which is to make cornea less deformable. Besides, corneas in NTG tended to be more deformable compared to those in HTG with long-term treatment of PGA.


Eye ◽  
2022 ◽  
Author(s):  
Ramin Salouti ◽  
Reza Razeghinejad ◽  
Gholamreza Eslami ◽  
Mousa Zare ◽  
Kia Salouti ◽  
...  