scholarly journals Is the Hemocytometer Obsolete for Body Fluid Cell Counting?

2016 ◽  
Vol 145 (3) ◽  
pp. 294-295 ◽  
Author(s):  
Linda M. Sandhaus
Keyword(s):  
2017 ◽  
Vol 473 ◽  
pp. 133-138 ◽  
Author(s):  
Michela Seghezzi ◽  
Barbara Manenti ◽  
Giulia Previtali ◽  
Maria Grazia Alessio ◽  
Paola Dominoni ◽  
...  

2017 ◽  
Vol 39 (3) ◽  
pp. 337-346 ◽  
Author(s):  
S. Buoro ◽  
M. Seghezzi ◽  
B. Manenti ◽  
T. Mecca ◽  
E. Candiago ◽  
...  

Author(s):  
Sabrina Buoro ◽  
Michela Seghezzi ◽  
Tommaso Mecca ◽  
Mauro Vavassori ◽  
Alberto Crippa ◽  
...  

AbstractBackground:Cellular analysis in cerebrospinal fluid (CSF) provides important diagnostic information in various medical conditions. The aim of this study was to evaluate the application of Mindray BC-6800 body fluid (BF) mode in cytometric analysis of CSF compared to light microscopy (LM).Methods:One hundred and twenty-nine consecutive CSF samples were analyzed by BC-6800-BF mode as well as by LM. The study also included limits of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), carryover and linearity.ResultsWhite blood cells LoQ was 4.0×10Conclusions:BC-6800-BF offers rapid and accurate counts in clinically relevant concentration ranges, replacing LM for most samples. However, in samples with abnormal cell counts or with abnormal white blood cell differential scattergrams the need to microscopic review for a correct clinical outcome remains.


2014 ◽  
Vol 631 ◽  
pp. 390-394 ◽  
Author(s):  
S.B. Cho ◽  
G.J. Yoon ◽  
E.M. An ◽  
Y.J. Kim ◽  
T.N. Kim ◽  
...  

We reported the apatite-forming ability of 30CaO∙70SiO2 scaffolds with 0~100 ppm Ag ions by soaking in simulated body fluid (SBF). This study was to evaluate the effects of the concentrations of Ag ions in the 30CaO∙70SiO2 gels on in-vitro biocompatibility of osteoblasts (MC3T3). After seeding cells on the surface of Ag-30CaO∙70SiO2 gels scaffold, cellular behaviors were evaluated by an assay of cell counting kit-8. Cytotoxicity of the scaffold samples was evaluated by employing the extract solutions of the scaffold samples by the assays of neutral red, MTT and BrdU. In addition, live & dead assay was performed by using a gel covering method, which the scaffolds have been directly contacted with the incubated cells on the well plate. According to the results of CCK-8 assay, the optical density value of the absorbance of the resulting solution decreased as the concentration of Ag ions in the scaffolds increased. Moreover, their cell viability was measured to be less than 50% at the Ag concentrations of 50 ppm or more, and dead cells were observed in the experiment results of both the cytotoxicity and gel covering tests. From these experimental results, we concluded that the Ag-30CaO∙70SiO2 scaffolds with less than 50 ppm Ag ion concentration were considered as biocompatible.


Author(s):  
Sonia Ortiz‐Nisa ◽  
Alba Sanz ◽  
Josep Pastor ◽  
Cristian Fuente ◽  
Sonia Añor

2015 ◽  
Vol 30 (5) ◽  
pp. 381-391 ◽  
Author(s):  
Sabrina Buoro ◽  
Sara Apassiti Esposito ◽  
MariaGrazia Alessio ◽  
Alberto Crippa ◽  
Cosimo Ottomano ◽  
...  

2020 ◽  
Vol 48 (4) ◽  
pp. 291-299
Author(s):  
Seung Geun Song ◽  
Jonghoon Lee ◽  
Jaemoon Koh ◽  
Sehui Kim ◽  
Doo Hyun Chung ◽  
...  

2007 ◽  
Vol 330-332 ◽  
pp. 593-596
Author(s):  
Keun Taek Oh ◽  
Kyoung Nam Kim ◽  
Dong Hoo Han ◽  
M.K. Chung ◽  
S.H. Hwang

The composition of the electrolytes used in the process of anodic oxidation was modified to generate the novel anodic oxidation. The surface topography of the novel anodic oxidation showed that the pore/crater structures with the precipitants attached over the surface were observed in SEM. The physical properties and biocompatibility of the surface with the novel anodic oxidation were compared with that of anodic oxidation and machined surface of titanium. XRD, Bioactivity in a simulated body fluid, cell proliferation, and MTT test were performed to evaluate the differences among different surfaces.


Sign in / Sign up

Export Citation Format

Share Document