scholarly journals 859 Follow up of distal radius volar plating – No role for post-operative radiographs

2021 ◽  
Vol 108 (Supplement_6) ◽  
Author(s):  
M S Cheruvu ◽  
J J Edakalathur ◽  
S J Pickard

Abstract Aim There is no consensus on the follow up for distal radius fractures after fixation. All patients receive intra-operative image intensifier screening to check the adequacy of reduction and implant position. We propose that if a patient is asymptomatic, you do not require post-operative radiographs. Method We conducted a retrospective review of all distal radius fractures operated in our hospital over the last 10 years. Data was collected from electronic records for revision surgery or metalwork removal. Records were assessed for patient symptoms, radiographic findings, and indications for implant removal. Patients had a minimum follow up of 6 months. Results 900 distal radius fixations were performed over a 10-year period, of which 747 were volar plating. 49 patients had volar plates removed. 14 patients had metal work removal and joint release for stiffness. 6 had the plate removal and carpal tunnel neurolysis with release. 11 implant removals for screw prominence. Other operative indications included reduction failure (n = 2), infection (n = 2) and removal in paediatric patients (n = 3). 47 of the 49 patients for implant removal were symptomatic at follow up. Only two patients had implant removal following isolated radiographic evidence of metalwork mal position. Conclusions Intra-operative intensifiers reduce the risk of implant and fixation errors. Routine post-operative radiographs altered the management of only 2 out of 700 (0.3%) patients. We suggest that radiographs have no role in routine post-operative care of distal radius fractures, where patients are asymptomatic with appropriate intra-operative intensifier images.

2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


CJEM ◽  
2007 ◽  
Vol 9 (01) ◽  
pp. 9-15 ◽  
Author(s):  
Khalid Al-Ansari ◽  
Andrew Howard ◽  
Brian Seeto ◽  
Solina Yoo ◽  
Salma Zaki ◽  
...  

ABSTRACT Background: Emergency department (ED) manipulation of complete minimally angulated distal radius fractures in children may not be necessary, due to the excellent remodeling potential of these fractures. Objectives: The primary objective of this study was to determine the proportion of minimally angulated distal radius fractures managed in the ED with plaster immobilization that subsequently required manipulation. Our secondary objective was to document, at follow-up, changes in angulation for each wrist fracture. Methods: This retrospective cohort study reviewed consecutive records of all children with bi-cortical minimally angulated (≤15° of angulation in the sagittal plane and ≤0.5 cm of displacement) distal metaphyseal radius fractures, alone or in combination with distal ulnar fracture. Details of treatment, radiographic findings, and clinical outcomes during the subsequent orthopedic follow up were recorded. Results: Of 124 patients included in the analysis, none required manipulation after their ED visit. All but 14 (11.3%) fractures were angulated ≤20° within the follow-up period. Two (1.6%) fractures that were initially angulated ≤15° progressed to 30°–35°, but remodeled within 2 years to nearly perfect anatomic alignment. By 6 weeks post-injury, no patients had clinically apparent deformity and all had normal function. Conclusions: Minimally angulated fractures of the distal metaphyseal radius managed in plaster immobilization without reduction in the ED are unlikely to require future surgical intervention.


Hand ◽  
2017 ◽  
Vol 13 (3) ◽  
pp. 346-349 ◽  
Author(s):  
Eric G. Huish ◽  
John G. Coury ◽  
Mohamed A. Ibrahim ◽  
Marc A. Trzeciak

Background: The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Methods: Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. Results: All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of −0.3 mm (−2.1 to 3.1 mm), and volar tilt of 7.9° (−3° to 15°). One patient had intra-articular step-off greater than 2 mm. Conclusions: Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.


2020 ◽  
Author(s):  
Xue-yang Gui ◽  
Hong-fei Shi ◽  
Jin Xiong ◽  
Yi-xin Chen ◽  
Jun-fei Wang ◽  
...  

Abstract Backgrounds: The aim of this study was to assess the efficacy of a modified intrafocal pinning technique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures.Methods: In total 35 AO/OTA type C2 and C3 fractures were finally included. The 3D digital model of the fracture was reconstructed based on preoperative computed tomographic (CT) images, with the displacement of the comminuted dorsal fragment and the intra-articular fragment analyzed for preoperative planning. During operation, a modified intrafocal pinning technique was applied percutaneously from the dorsal aspect of the radius to reduce the collapsed intra-articular fragment following volar plating. Adequate reduction was confirmed in all of patients considering radial height, radial inclination and volar tilt in postoperative radiographs.Results: No significant fracture re-displacement was observed in most of the cases during a mean follow-up period of 17.4 months, except for two patients with the C3 fracture. All of the patients achieved adequate clinical ROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achieved an excellent (n = 21) or good (n = 12) Gartland and Werley wrist score.Conclusions: Our modified intrafocal pinning technique with 3D planning contributes to a satisfactory clinical and radiological outcome in dorsally comminuted intra-articular distal radius fractures fixed with a volar locking plate.Trial registration: Not applicable because the design of the study is retrospective.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xue-yang Gui ◽  
Hong-fei Shi ◽  
Jin Xiong ◽  
Yi-xin Chen ◽  
Jun-fei Wang ◽  
...  

Abstract Backgrounds Theaim of this study was to assess the efficacy of a modified intrafocal pinningtechnique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures. Methods Intotal 35 AO/OTA type C2 and C3 fractures were finally included.The 3D digital model of the fracture was reconstructed based on preoperative computedtomographic (CT) images, with the displacement of the comminuted dorsalfragment and the intra-articular fragment analyzed for preoperative planning. During operation, amodified intrafocal pinning technique was applied percutaneously from thedorsal aspect of the radius to reduce the collapsed intra-articular fragmentfollowing volar plating. Adequate reduction was confirmed in all of patientsconsidering radial height, radial inclination and volar tilt in postoperativeradiographs. Results No significant fracture re-displacement wasobserved in most of the cases during a mean follow-up period of 17.4 months, exceptfor two patients withthe C3 fracture. All of the patients achieved adequate clinicalROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achievedan excellent (n = 21) or good (n = 12) Gartland and Werley wrist score. Conclusions Ourmodified intrafocal pinning technique with 3D planning contributes to a satisfactoryclinical and radiological outcome in dorsally comminuted intra-articular distalradius fractures fixed with a volar locking plate. Trialregistration Notapplicable because the design of the study is retrospective.


Hand ◽  
2021 ◽  
pp. 155894472199973
Author(s):  
Nicholas Munaretto ◽  
Adam Tagliero ◽  
Raahil Patel ◽  
Peter C. Rhee

Background Little information exists to guide decision-making with regard to distal radius fractures in the setting of ipsilateral hemiparesis or hemiplegia. Methods Patients who sustained a distal radius fracture in the setting of ipsilateral hemiparesis or hemiplegia secondary to brain injury were evaluated. Investigated variables included perioperative pain, preinjury House functional classification score, length of immobilization, radiographic outcome measurements, and time to union. Results There were 15 patients with distal radius fractures with a mean age of 65.9 years. The mean clinical and radiographic follow-up was 2.8 and 2.9 years, respectively. Wrists were placed into the nonoperative group (NOG, n = 10) and operative group (OG, n = 5). Pain significantly decreased at final follow-up for both groups. Baseline House functional classification scores averaged 1.3 and 1.6 for the NOG and OG, respectively, and were maintained at final follow-up. Length of immobilization for the NOG was 46 days and OG was 37 days, P = .15. Radiographic outcomes at final follow-up in the NOG and OG, respectively, were a mean radial height of 9.3 versus. 11.6 mm, radial inclination of 18.3° versus 22.3°, 4.2° dorsal tilt versus 5.3° volar tilt, and tear drop angle of 45.6° versus 44.5°. There were no significant differences in these measurements. Time to radiographic union averaged 58 days for the NOG and 67 days for the OG, P = .42. There were no revision surgeries. Conclusions Based on this small case series, patients with distal radius fracture and ipsilateral hemiparesis or hemiplegia may have similar clinical, functional, and radiographic outcomes, regardless of nonoperative or operative treatment.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


2014 ◽  
Vol 15 (1) ◽  
Author(s):  
Paul Ruckenstuhl ◽  
Gerwin A Bernhardt ◽  
Patrick Sadoghi ◽  
Mathias Glehr ◽  
Lukas A Holzer ◽  
...  

Author(s):  
M. Carolina Orbay ◽  
Jorge L. Orbay

AbstractGreater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.


Sign in / Sign up

Export Citation Format

Share Document