Volar Plating for Distal Radius Fractures—Do Not Trust the Image Intensifier When Judging Distal Subchondral Screw Length

2012 ◽  
Vol 16 (3) ◽  
pp. 169-172 ◽  
Author(s):  
Derek H. Park ◽  
Boyd S. Goldie
2021 ◽  
Vol 108 (Supplement_6) ◽  
Author(s):  
M S Cheruvu ◽  
J J Edakalathur ◽  
S J Pickard

Abstract Aim There is no consensus on the follow up for distal radius fractures after fixation. All patients receive intra-operative image intensifier screening to check the adequacy of reduction and implant position. We propose that if a patient is asymptomatic, you do not require post-operative radiographs. Method We conducted a retrospective review of all distal radius fractures operated in our hospital over the last 10 years. Data was collected from electronic records for revision surgery or metalwork removal. Records were assessed for patient symptoms, radiographic findings, and indications for implant removal. Patients had a minimum follow up of 6 months. Results 900 distal radius fixations were performed over a 10-year period, of which 747 were volar plating. 49 patients had volar plates removed. 14 patients had metal work removal and joint release for stiffness. 6 had the plate removal and carpal tunnel neurolysis with release. 11 implant removals for screw prominence. Other operative indications included reduction failure (n = 2), infection (n = 2) and removal in paediatric patients (n = 3). 47 of the 49 patients for implant removal were symptomatic at follow up. Only two patients had implant removal following isolated radiographic evidence of metalwork mal position. Conclusions Intra-operative intensifiers reduce the risk of implant and fixation errors. Routine post-operative radiographs altered the management of only 2 out of 700 (0.3%) patients. We suggest that radiographs have no role in routine post-operative care of distal radius fractures, where patients are asymptomatic with appropriate intra-operative intensifier images.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


Author(s):  
M. Carolina Orbay ◽  
Jorge L. Orbay

AbstractGreater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.


2017 ◽  
Vol 43 (2) ◽  
pp. 142-147 ◽  
Author(s):  
Daniel Martinez-Mendez ◽  
Alejandro Lizaur-Utrilla ◽  
Joaquin de-Juan-Herrero

We compared outcomes in elderly patients with intra-articular distal radius fractures treated by closed reduction and plaster immobilization or open reduction and internal fixation with a volar plate. Ninety-seven patients older than 60 years were randomly allocated to conservative (47 patients) or surgical (50 patients) treatment. Over a 2-year period, we assessed patient-rated wrist evaluation score, DASH (disability arm, shoulder and hand) questionnaire, pain, wrist range of motion, grip strength, and radiological parameters. The functional outcomes and quality of life were significantly better after volar plating fixation compared with conservative treatment. We found that restoration of the articular surface, radial inclination, and ulnar variance affected the outcomes, but the articular step-off did not. Twenty-five per cent of the patients with conservative treatment had secondary loss of reduction. We conclude that surgical plating leads to better outcomes than conservative treatment for elderly patients with intra-articular distal radius fractures. Level of evidence: I


2021 ◽  
pp. 445-459
Author(s):  
Stephanie Catherine Spence ◽  
Benjamin Hope ◽  
Mark Ross

Hand ◽  
2020 ◽  
pp. 155894472097640
Author(s):  
Nathaniel Fogel ◽  
Lauren M. Shapiro ◽  
Allison Roe ◽  
Sahitya Denduluri ◽  
Marc J. Richard ◽  
...  

Background Intra-articular distal radius fractures with small volar lunate facet fragments can be challenging to address with volar plate fixation alone. Volar locked plating with supplementary spring wire fixation has been previously described in a small series but has not been further described in the literature. We hypothesized that this technique can provide adequate fixation for volar lunate facet fragments smaller than 15 mm in length, which are at risk of displacement. Methods We completed a retrospective chart review (2015-2019) of patients who underwent volar locked plating with the addition of supplementary spring wire fixation for intra-articular distal radius fractures with a volar lunate facet fragment (<15 mm). Postoperative radiographs were assessed to evaluate union, evidence of hardware failure, escape of the volar lunate facet fragment, and postoperative volar tilt. Clinical outcome was assessed with wrist flexion/extension, arc of pronosupination, and Quick Disabilities of the Arm, Shoulder, and Hand Score ( QuickDASH) scores. Results Fifteen patients were identified, of which all went on to fracture union. There were no hardware failures or escape of the volar lunate facet fragment at final follow-up. One patient underwent hardware removal for symptoms of flexor tendon irritation. The mean wrist flexion was 59°, wrist extension was 70°, pronation was 81°, and supination was 76°. The mean QuickDASH score was 18.5. The mean postoperative volar tilt was 3.6°. Conclusions Supplementary spring wire fixation with standard volar plating provides stable fixation for lunate facet fragments less than 15 mm. This technique is a safe and reliable alternative to commercially available fragment-specific implants.


Sign in / Sign up

Export Citation Format

Share Document