Micro-scale method for liquid-chromatographic determination of chloramphenicol in serum.

1979 ◽  
Vol 25 (7) ◽  
pp. 1300-1302 ◽  
Author(s):  
S H Petersdorf ◽  
V A Raisys ◽  
K E Opheim

Abstract We describe the use of "high-performance" liquid chromatography to measure chloramphenicol in as little as 25 microL of serum. Serum is treated to precipitate proteins with acetonitrile containing p-nitroacetanilide as an internal standard. Chloramphenicol is eluted with a mobile phase of methanol in pH 7.0 phosphate buffer (35/65 by vol). The drug is measured at 278 nm and simultaneously monitored at 254 nm; interfering substances are detected by examining the 278 nm/254 absorbance ratios. This method is sensitive to less than 0.5 mg/L and the standard curve is linear to at least 50 mg/L. Inter-day precision ranged between 3--6%. We encountered no interference from endogenous compounds or from other drugs we tested.

1984 ◽  
Vol 30 (7) ◽  
pp. 1228-1230 ◽  
Author(s):  
A K Dhar ◽  
H Kutt

Abstract This method for determination of haloperidol in plasma is based on "high-performance" isocratic liquid chromatography with the use of a C8 bonded reversed-phase column at room temperature. Haloperidol and the internal standard (chloro-substituted analog) are extracted from alkalinized plasma into isoamyl alcohol/heptane (1.5/98.5 by vol) and back-extracted into dilute H2SO4. The aqueous phase is directly injected onto the column. The mobile phase is a 30/45/25 (by vol) mixture of phosphate buffer (16.5 mmol/L, pH 7.0), acetonitrile, and methanol. Unlike other liquid-chromatographic procedures for haloperidol, commonly used psychotropic drugs do not interfere. Analysis can be completed within an hour. The procedure is extremely sensitive (1.0 microgram/L) and is well reproducible (CV 5.6% for a 2.5 micrograms/L concentration in plasma).


1983 ◽  
Vol 29 (10) ◽  
pp. 1840-1842 ◽  
Author(s):  
J Lehmann ◽  
H L Martin

Abstract We have adapted to erythrocytes a method for the determination of alpha- and gamma-tocopherols in plasma and platelets. Erythrocytes (50 microL) were extracted with methanol containing tocol (internal standard) and pyrogallol. Tocopherols were partitioned into chloroform, washed, and injected in methanol onto a reversed-phase (C18) "high-performance" liquid-chromatographic column. The mobile phase was methanol/water (99/1 by vol) at a flow rate of 2 mL/min and detection was with a "high-performance" spectrophotofluorometer. The limit of detection for either tocopherol is 0.10 microgram/mL of packed cells. Analytical recoveries ranged from 93 to 104%. Some values for tocopherols in human erythrocytes are presented.


2003 ◽  
Vol 68 (11) ◽  
pp. 883-892 ◽  
Author(s):  
Dragica Zendelovska ◽  
Trajce Stafilov

A rapid, specific and sensitive high-performance liquid chromatographic method for the determination of famotidine in human plasma has been developed. Famotidine and the internal standard were chromatographically separated from plasma components using a Lichrocart Lichrospher 60 RP select B cartridge for solid-phase separation with a mobile phase composed of 0.1 % (v/v) triethylamine in water (pH 3) and acetonitrile (92:8, v/v). UV detection was set at 270 nm. The calibration curve was linear in the concentration range of 10.0 ? 350.0 ng mL-1. The method was implemented to monitor the famotidine levels in patient samples.


1986 ◽  
Vol 69 (5) ◽  
pp. 915-918
Author(s):  
Edward J Kikta ◽  
◽  
E Bane ◽  
A Burns ◽  
A Christensen ◽  
...  

Abstract A liquid chromatographic (LC) method for the analysis of technical and formulated carbofuran samples was evaluated in a collaborative study. Carbofuran is determined by reverse phase LC, using a water-methanol mobile phase and acetophenone as internal standard, and detected at 280 nm. Twelve samples, 5 formulations and technical matched pairs, were analyzed by 17 collaborating laboratories. Accuracy and variability of results are typical of large LC data sets. The method has been adopted official first action.


1982 ◽  
Vol 65 (3) ◽  
pp. 753-756
Author(s):  
Walter F Schmidt

Abstract A high performance liquid chromatographic procedure has been developed for the assay of phenprocoumon in tablets. In comparison to the present official USP assay procedure, it is equivalent in precision and accuracy and is faster and more specific. A mobile phase consisting of a 1% solution of acetic acid in acetonitrile-water (4 + 3) separates phenprocoumon from warfarin internal standard on a 6 μm octadecylsilane (ODS) column with UV detection at 311 nm. The method enables the concurrent determination of phenprocoumon and possible contaminants such as salicylic acid.


1984 ◽  
Vol 30 (1) ◽  
pp. 140-143 ◽  
Author(s):  
J R Shipe ◽  
J Savory ◽  
M R Wills

Abstract In this improved method for quantifying 3-methoxy-4-hydroxyphenylethyleneglycol (MHPG) in urine, after a multistep extraction of MHPG and internal standard (iso-MHPG) from 3.0 mL of urine, the compounds are separated on a C18 reversed-phase column and quantified by use of an electro-chemical detector. The isocratic chromatographic separation takes about 16 min. The mobile phase is phosphate buffer/acetonitrile (88/12 by vol), the flow rate 0.7 mL/min. Recycling the mobile phase and automating the sample injection make possible the unattended assay of more than 70 samples per day. The within-run precision of the method is excellent (CV 1.8%) at a mean concentration of 1.1 mg/L.


1982 ◽  
Vol 65 (5) ◽  
pp. 1063-1065
Author(s):  
Stanley E Roberts

Abstract A high performance liquid chromatographic (HPLC) method is described for the quantitative determination of primidone in tablets. A ground tablet sample is diluted directly in the mobile phase, at a concentration of about 1 mg/mL of primidone, mixed and deaerated, and filtered. The resulting solution is then quantitated by HPLC. The average spike recoveries for the 50 mg and 250 mg tablets were 101.2% and 99.0%, respectively. The average recovery for an authentic mixture formulated at the 250 mg level was 100.1% with a relative standard deviation of 0.45%.


1982 ◽  
Vol 28 (10) ◽  
pp. 2143-2148 ◽  
Author(s):  
P M Edelbroek ◽  
E J de Haas ◽  
F A de Wolff

Abstract To study correlations between the concentrations, in serum, of amitriptyline and its most important metabolites with clinical response in patients, we developed a "high-performance" liquid-chromatographic method for routine determination of amitriptyline, nortriptyline, total 10-hydroxy-amitriptyline, desmethylnortriptyline, and E(trans)- and Z(cis)-10-hydroxynortriptyline. These compounds are extracted from 1 mL of alkalinized serum into hexane/isoamyl alcohol (99/1 by vol). Perazine is the internal standard. To minimize irreversible adsorption of the drugs onto the glassware, 5 micrograms of maprotiline is added to the organic phase just before evaporation. After a 10-min resolution on a silica column eluted with acetonitrile/methanol/NH4OH (1 mol/L), absorbance is measured at 240 nm. Only chlorimipramine, doxepin, procainamide, and N-acetylprocainamide may interfere with assay of the compounds that probably are therapeutically relevant: amitriptyline, nortriptyline, and E-10-hydroxynortriptyline. Uremia, lipemia, and icterus also do not affect the analysis.


1981 ◽  
Vol 27 (3) ◽  
pp. 437-440 ◽  
Author(s):  
D R Uges ◽  
P Bouma

Abstract We have developed "high-performance" liquid-chromatographic methods for determining 4-aminopyridine, an acetylcholine-releasing drug, in serum, saliva, and urine. As little as 1 microgram/L can be detected by extracting the alkalinized sample plus the internal standard (3,4-diaminopyridine) into dichloromethane, mixing the organic phase with 1-pentanol, evaporating the dichloromethane, and injecting the residue onto a reversed-phase column, where it is eluted with acetonitrile/methanol/aqueous ammonium carbonate, with detection at 245 nm. Analytical recoveries from serum averaged 86.7%. The CV at 50 micrograms/L was 2.9% (n = 8). For urine samples containing very high concentrations of 4-aminopyridine, we mixed urine and potassium carbonate in an automatic injector vial, extracted the drug into dichloromethane, centrifuged, and injected an aliquot of the extract into the chromatograph. Analytical recoveries averaged 92%, and the CV was about 2% for drug concentrations of 0.1-8 mg/L of urine.


Sign in / Sign up

Export Citation Format

Share Document