Ratio of Creatine Kinase 2 Mass Concentration to Total Creatine Kinase Activity not Altered by Heavy Physical Exercise

1992 ◽  
Vol 38 (11) ◽  
pp. 2224-2227 ◽  
Author(s):  
J Ordóñez-Llanos ◽  
J R Serra-Grima ◽  
J Mercé-Muntañola ◽  
F González-Sastre

Abstract Serum creatine kinase isoenzyme 2 concentrations (CK 2 mass) were measured in marathon runners during training and 1 and 2 days after a race and compared with values from 36 acute myocardial infarction (AMI) patients whose total CK and (or) CK 2 activities were similar to those of runners in the basal state. During training, runners had CK and CK 2 activities 53% and 43% above reference values, respectively, and 36% had CK 2 activity > 5% of total CK. Nine runners (26%) showed CK 2 mass values > 6 micrograms/L but < or = 10 micrograms/L; 35 of the AMI subjects, despite having CK activities similar to those of runners, had values > 10 micrograms/L. The ratio of CK 2 mass to total CK activity was significantly (P < 0.0002) different between sexes for runners. At 1 and 2 days after racing, 100% of CK and CK 2 activities and 71% and 57% of the percentages of CK 2 activity, respectively, were abnormally high; 57% and 43% of CK 2 mass values were > 10 micrograms/L, being comparable with those observed for the AMI group. Basal CK 2 mass values of the runners appeared only slightly higher than that for sedentary subjects, but after exercise half the subjects presented increased values similar to those observed for AMI subjects. The ratio of CK 2 mass to total CK activity appeared unaltered by exercise in all but one of the samples assayed, indicating its utility in evaluating CK 2 mass increases originating in skeletal muscle.

1975 ◽  
Vol 21 (8) ◽  
pp. 1088-1092 ◽  
Author(s):  
Donald W Mercer ◽  
Murray A Varat

Abstract We describe a spectrophotometric kinetic assay for detecting creatine kinase MB isoenzyme activity in the 1 to 10 U/liter range. The MB isoenzyme was isolated [Clin. Chem. 20, 36 (1974)] and assayed (Rosalki method) with an Abbott ABA-100. Good reproducibility was demonstrated for MB isoenzyme activities near 1 U/liter (CV = 2.6%). Sera with normal or slightly increased total creatine kinase activity were evaluated. Sera of 14 patients with acute myocardial infarction contained, per liter, 84 to 236 U of total creatine kinase activity and 4.6 to 28.0 U of isoenzyme MB activity; corresponding ranges for sera from healthy lab technicians and patients with noncardiac disease were 36 to 277 and 0 to 2.6 U. MB isoenzyme activity for infarction patients rose and fell sharply within three days after the infarction. Atypical time-course patterns, MB isoenzyme activity remaining abnormally great for five days, were observed in serum from patients with prolonged atrial fibrillation and congestive heart failure or cardiomyopathy; the BB isoenzyme (1 to 5 U/liter) was also detected in sera of such patients but was absent in sera from infarction patients. Quantification of column-isolated MB by the assay described is rapid, easy, specific, and extremely sensitive for measuring MB in the 1 to 10 U/liter range.


1978 ◽  
Vol 24 (5) ◽  
pp. 832-834 ◽  
Author(s):  
L Ljungdahl ◽  
W Gerhardt

Abstract In serum from about 800 patients, total creatine kinase and its subunit B activities were determined by the recommended Scandinavian creatine kinase method in the absence and presence of a creatine kinase M subunit inhibitory antibody. Eight patients had supranormal subunit B activities, but normal or near-normal values for total creatine kinase activity. Electrophoresis of sera from these eight patients showed, in addition to the normally migrating isoenzyme MM, one or two abnormally migrating creatine kinase isoenzyme bands, located between normally migrating isoenzymes MM and MB. Experimental data suggest that these abnormal bands may be isoenzyme BB with changed electrophoretic mobility. The eight patients had no particular disorder in common.


1983 ◽  
Vol 29 (3) ◽  
pp. 533-538
Author(s):  
T H Massey ◽  
W C Butts

Abstract We have adapted to a microcentrifugal analyzer an immunoinhibition assay for measuring the activity of creatine kinase MB by using an inhibitory antibody for the M monomer. The method actually measures half the MB activity, but results are not multiplied by two because atypical isoenzymes of creatine kinase, including BB, IgG-BB, and the isoenzyme derived from mitochondria, are also detected, if they are present. Results correlated well with an electrophoresis method for 36 serum samples. Myocardial infarction was assessed in 175 patients admitted to our coronary-care unit, with respect to sensitivity (100%) and specificity (98%) when a decision point of 100 U/L (30 degrees C) was chosen for total creatine kinase activity (dithiothreitol-activated) and 6 U/L (30 degrees C) for the isoenzyme (by immunoinhibition). Atypical isoenzymes are easily recognized and confirmed by electrophoresis when the MB activity (by immunoinhibition) exceeds 6 U/L and 20% of the total creatine kinase activity.


1985 ◽  
Vol 31 (10) ◽  
pp. 1616-1620 ◽  
Author(s):  
M C Wimmer ◽  
J D Artiss ◽  
B Zak

Abstract We describe a peroxidase-coupled method involving a colorimetric indicator reaction for determining the total activity of creatine kinase (EC 2.7.3.2) in serum. The kinetically favorable reverse reaction is exploited to generate adenosine 5'-triphosphate, which is used in the glycerol kinase-catalyzed phosphorylation of glycerol. The glycerol 3-phosphate so generated is oxidized in the presence of alpha-glycerophosphate oxidase to produce hydrogen peroxide, which is reduced in the presence of peroxidase with the simultaneous oxidation and coupling of 4-aminoantipyrene and 2-hydroxy-3,5-dichlorobenzenesulfonate to produce an intensely colored red chromogen. Results of the proposed method (y) correlate well with those of the Boehringer-Mannheim "CK-NAC UV" method as applied to the Hitachi 705 chemistry analyzer (y = 1.025 chi - 18.1, r = 0.9985, n = 100, range = 19-4531 U/L). The sensitivity of the method, based on molar absorptivities, is nearly fourfold that of procedures involving the reduction of NADP+.


1988 ◽  
Vol 34 (11) ◽  
pp. 2208-2210 ◽  
Author(s):  
W G Thompson ◽  
R G Mahr ◽  
W S Yohannan ◽  
M R Pincus

Abstract The usefulness of measuring creatine kinase MB isoenzyme for diagnosing myocardial infarction when activities of total creatine kinase are very high is unclear. We conducted a retrospective study in an urban hospital that serves a largely indigent population. We concentrated on 146 patients whose creatine kinase activity was greater than 1000 U/L (upper limit of normal: 165 U/L for women and 225 U/L for men), with MB isoenzyme greater than 10 U/L and less than 5% of total creatine kinase. The positive predictive value of MB isoenzyme (isoimmune method) values greater than 10 U/L was between 11.6% and 56.8% when the value for total creatine kinase exceeded 1000 U/L. Using different values (MB greater than 4% of total creatine kinase) as positive for myocardial infarction would have resulted in far fewer false-positives, but 10 cases of myocardial infarction would have been missed. The most appropriate cutoff value for MB isoenzyme in this population (total creatine kinase greater than 1000 U/L) was found to be greater than 2% of total creatine kinase.


1998 ◽  
Vol 377 (1) ◽  
pp. 1-12 ◽  
Author(s):  
Géza Nagy ◽  
Clarke X. Xu ◽  
Richard P. Buck ◽  
Ernó Lindner ◽  
Michael R. Neuman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document