Findings of an external quality assessment scheme for determining aluminum in dialysis fluids and water

1994 ◽  
Vol 40 (8) ◽  
pp. 1517-1521 ◽  
Author(s):  
A Taylor ◽  
R J Briggs ◽  
C Cevik

Abstract The analytical performance of laboratories participating in the dialysis fluids and water aluminum program of the Guildford External Quality Assessment Scheme over the period 1986-1993 has been reviewed. For aluminum concentrations > 3.33 mumol/L in dialysis fluids, the between-laboratory CV has fallen from approximately 36% to 23%, whereas for specimens of water the reduction was from 36% to approximately 18%. Improvements at lower concentrations were less impressive. Performance of individual participants varied; only a few consistently provided accurate results. Many of the participants are able to measure serum aluminum well, so lack of expertise is not responsible for poor results. We suggest that matrix effects associated with different specimen types have a significant influence on performance and that due account is not always taken of these factors. Resolution of these problems would be aided by appropriate reference materials.

Author(s):  
W A Ratcliffe ◽  
G D Carter ◽  
M Dowsett ◽  
S G Hillier ◽  
J G Middle ◽  
...  

This paper reports on the provision of a clinical biochemistry service for serum oestradiol. The pathophysiology and recognised applications of oestradiol assays are discussed and the current availability of assay reagents and methodologies reviewed. Data are presented on the analytical performance of assays for serum oestradiol in the UK External Quality Assessment Scheme (UKEQAS) and general guidance is offered to laboratories providing a diagnostic service for this analyte.


2017 ◽  
Vol 100 (5) ◽  
pp. 1277-1287 ◽  
Author(s):  
Carolyn Q Burdette ◽  
Johanna E Camara ◽  
Federica Nalin ◽  
Jeanita Pritchett ◽  
Lane C Sander ◽  
...  

Abstract Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standardsand Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the resultsof the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assignedvalues and the ALTM was 5.6%, with 10% of the samples having biases >10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.