Integration of transthoracic focused cardiac ultrasound in the diagnostic algorithm for suspected acute aortic syndromes

2019 ◽  
Vol 40 (24) ◽  
pp. 1952-1960 ◽  
Author(s):  
Peiman Nazerian ◽  
Christian Mueller ◽  
Simone Vanni ◽  
Alexandre de Matos Soeiro ◽  
Bernd A Leidel ◽  
...  

Abstract Aims The diagnosis of acute aortic syndromes (AASs) is challenging and requires integrated strategies. Transthoracic focused cardiac ultrasound (FoCUS) is endorsed by guidelines as a first-line/triage tool allowing rapid bedside assessment of the aorta. However, the performance of FoCUS in the European Society of Cardiology-recommended workup of AASs awaits validation. Methods and results This was a prespecified subanalysis of the ADvISED multicentre prospective study. Patients with suspected AAS underwent FoCUS for detection of direct/indirect signs of AAS. Clinical probability assessment was performed with the aortic dissection detection risk score (ADD-RS). Case adjudication was based on advanced imaging, surgery, autopsy, or 14-day follow-up. An AAS was diagnosed in 146 (17.4%) of 839 patients. Presence of direct FoCUS signs had a sensitivity and specificity of 45.2% [95% confidence interval (CI) 37–53.6%] and 97.4% (95% CI 95.9–98.4%), while presence of any FoCUS sign had a sensitivity and specificity of 89% (95% CI 82.8–93.6%) and 74.5% (95% CI 71–77.7%) for AAS. The additive value of FoCUS was most evident within low clinical probability (ADD-RS ≤1). Herein, direct FoCUS signs were identified in 40 (4.8%) patients (P < 0.001), including 29 with AAS. ADD-RS ≤1 plus negative FoCUS for AAS rule-out had a sensitivity of 93.8% (95% CI 88.6–97.1%) and a failure rate of 1.9% (95% CI 0.9–3.6%). Addition of negative D-dimer led to a failure rate of 0% (95% CI 0–1.2%). Conclusion FoCUS has additive value in the workup of AASs. Direct FoCUS signs can rapidly identify patients requiring advanced imaging despite low clinical probability. In integrated bundles, negative FoCUS is useful for rule-out of AASs.

2019 ◽  
Vol 26 (11) ◽  
pp. 1255-1265 ◽  
Author(s):  
Peiman Nazerian ◽  
Emanuele Pivetta ◽  
Simona Veglia ◽  
Edoardo Cavigli ◽  
Christian Mueller ◽  
...  

2021 ◽  
Vol 2021 (2) ◽  
Author(s):  
Gini Priyadharshini Jeyashanmugaraja ◽  
Evgeny Shloknik ◽  
Deborah Tosin Akanya ◽  
Kristin Stawiarski ◽  
Christopher Winterbottom ◽  
...  

ABSTRACT A 63-year-old woman was admitted with severe respiratory distress requiring mechanical ventilation and shock requiring vasopressor support. She was found to have COVID-19 pneumonia. Focused cardiac ultrasound performed for evaluation of shock was significant for right ventricular dilation and dysfunction with signs of right ventricular pressure overload. Given worsening shock and hypoxemia systemic thrombolysis was administered for presumed massive pulmonary embolism with remarkable improvement of hemodynamics and respiratory failure. In next 24 h patient’s neurologic status deteriorated to the point of unresponsiveness. Emergent computed tomography showed multiple ischemic infarcts concerning for embolic etiology. Focused cardiac ultrasound with agitated saline showed large right to left shunt due to a patent foramen ovale. This was confirmed by transesophageal echocardiogram, 5 months later. This case highlights strengths of focused cardiac ultrasound in critical care setting and in patients with COVID-19 when access to other imaging modalities can be limited.


2012 ◽  
Vol 107 (02) ◽  
pp. 369-378 ◽  
Author(s):  
Jan Schwonberg ◽  
Carola Hecking ◽  
Marc Schindewolf ◽  
Dimitrios Zgouras ◽  
Susanne Lehmeyer ◽  
...  

SummaryThe diagnostic value of D-dimer (DD) in the exclusion of proximal deep-vein thrombosis (DVT) is well-established but is less well-known in the exclusion of distal (infrapopliteal) DVT. Therefore, we evaluated the diagnostic abilities of five DD assays (Vidas-DD, Liatest-DD, HemosIL-DD, HemosIL-DDHS, Innovance-DD) for excluding symptomatic proximal and distal leg DVT. A total of 243 outpatients whose symptoms were suggestive of DVT received complete compression ultrasonography (cCUS) of the symptomatic leg(s). The clinical probability of DVT (PTP) was assessed by Wells score. Thirty-eight proximal and 31 distal DVTs (17 tibial/fibular DVTs, 14 muscle DVTs) were diagnosed by cCUS. Although all assays showed high sensitivity for proximal DVT (range 97–100%), the sensitivity was poor for distal DVT (range 78–93%). None of the assays were individually able to rule out all DVTs as a stand-alone test (negative predictive value [NPV] 91–96%). However, a negative DD test result combined with a low PTP exhibited a NPV of 100% for all DVTs (including proximal, tibial/fibular, and muscle DVTs) with the HemosIL-DDHS and Innovance-DD. All proximal and tibial/fibular DVTs, but not all muscle DVTs, could be ruled out with this strategy using the Liatest-DD and Vidas-DD. The HemosIL-DD could not exclude distal leg DVT, even in combination with a low PTP. The combination of a negative DD with a low PTP showed a specificity of 32–35% for all DVTs. In conclusion, our study shows that when used in conjunction with a low PTP some DD assays are useful tools for the exclusion of distal leg DVT.


2015 ◽  
Vol 34 (4) ◽  
pp. 727-736 ◽  
Author(s):  
Joseph Minardi ◽  
Tom Marshall ◽  
Greta Massey ◽  
Erin Setzer

Sign in / Sign up

Export Citation Format

Share Document