5202Zero- or near-zero fluoroscopy radiofrequency catheter ablation for aortic sinus cusp idiopathic ventricular arrhythmias

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
S Stec ◽  
K Styczkiewicz ◽  
J Sledz ◽  
M Chrabaszcz ◽  
B Ludwik

Abstract Background Complete elimination of fluoroscopy during radiofrequency catheter ablation (RFCA) of idiopathic ventricular arrhythmias (IVA) originating from aortic sinus cusp (ASC) may be challenging, requires confirmation of coronary arteries ostia and could be associated with potential risk of collateral damage and severe complications. Purpose To validate the implementation, feasibility, learning curve, safety and efficacy of zero-fluoroscopy (ZF) approach in centers using near-zero fluoroscopy (NOX) approach for RFCA of idiopathic premature ventricular complexes/ventricular tachycardias (PVCs/VTs) from ASC. Methods From 2012 to 2018, we prospectively enrolled 106 consecutive patients (age: 49±19, males: 58%, children: 7%, 108 PVC/VT focuses from ASC, PVCs/24h: 23808±22006) with ASC-IVA. Patients were unselected and referred for ZF or NOX approach using three dimensional electroanatomic system- 3D EAM without intracardiac or transesophageal echocardiography. The choice of ZF and NOX was based on the first operator experience and from 2014 three experienced operators and three fellows performed ZF as an intention-to-treat approach. The peri-procedural, short-term outcome as well as learning curve of ZF in ASC were evaluated with documentation of reasons for cross-over to NOX approach. Results Out of 108 focuses there were majority of left coronary cusps and left/right junctions sites of origin [other rare locations: right coronary cusp (n=7); non-coronary cusp, n=6)]. On intention-to-treat 61/76 (80%) cases were completed without fluoroscopy in ZF-approach. Additionally, 30/30 (100%) cases were completed with NOX. The main reasons for fluoroscopy use in ZF approach (conversion to NOX) were: the need for elective valsalvography plus coronary angiography (n=6), urgent coronary angiography due to validation of transient uncomplicated coronary spasms and ST elevation (n=2), catheter stability checking (n=2), femoral access site confirmation (n=1) and navigation problem (n=1). No significant differences were found in the acute and short-term success rates between ZF and NOX (90% vs 88%, P=NS) and no major complications occurred. The procedure time, fluoroscopy time and ablation time were 66.8±26.9; 3.6±7.2 and 7.3±5.5 min, respectively. The gathering experience of ZF approach, computer-assisted ECG analysis and 3D-EAM reconstruction of aortic root and coronary artery ostia resulted in significant reduction of NOX approach between early and late period [median (n=53): 2012–2016 vs 2017–2018, 40/53 (76%) vs 5/53 (8%), p<0.001]. Conclusion ZF can be completed in majority of patients with ASC-IVA especially after appropriate training and operators' experience with NOX. ZF approach guided by 3D-EAM is feasible, safe, and effective for treatment of ASC-IVA with importance of training and preprocedural imaging for exclusion of coronary anomalies or validation of coronary arteries ostia by 3D-EAM.

Heart Rhythm ◽  
2014 ◽  
Vol 11 (7) ◽  
pp. 1117-1121 ◽  
Author(s):  
Kurt S. Hoffmayer ◽  
Thomas A. Dewland ◽  
Henry H. Hsia ◽  
Nitish Badhwar ◽  
Jonathan C. Hsu ◽  
...  

2012 ◽  
Vol 4 (2) ◽  
pp. 139-147
Author(s):  
S Hashem ◽  
M Hossain ◽  
MA Ali ◽  
AK Choudhury ◽  
AA Masum

Background : This study was conducted to compare the conventional retrograde arterial approach (RAA) with the transeptal approach (TSA) for radiofrequency catheter ablation (RFA) of left accessory pathways (AP). Materials and Methods: Sixty consecutive patients (44 male; mean age of 35.60 ± 11.63 years) with 60 left APs (39 overt and 21 concealed) underwent catheter ablation using the TS method (30 patients) and the RA method (30 patients) in an alternate fashion. The analysis was performed according to the intention-to-treat principle. Results : The transeptal puncture was successfully performed in 29 patients (96%). This access allowed primary success in the ablation in all the patients without any complication. When we compared this approach with the RAA there was no difference as regards the primary success (p = 0.103), fluoroscopy time (p = 0.565) and total time (p = 0.1917). Three patient in the RAA group presented a vascular complication. The TSA allowed shorter ablation times (p=0.006) and smaller number of radiofrequency applications (p = 0.042) as compared to the conventional RAA. The patients who had unsuccessful ablation in the first session in each approach underwent with the opposite technique (cross-over), with a final ablation success rate of 100%. Conclusion : The TS and RA approaches showed similar efficacy and safety for the ablation of left accessory pathways. The TSA allowed shorter ablation times and smaller number of radiofrequency applications. When the techniques were used in a complementary fashion, they increased the final efficacy of the ablation DOI: http://dx.doi.org/10.3329/cardio.v4i2.10458 Cardiovasc. j. 2012; 4(2): 139-147


Medicine ◽  
2016 ◽  
Vol 95 (36) ◽  
pp. e4648 ◽  
Author(s):  
Lingmin Wu ◽  
Yanlai Lu ◽  
Yan Yao ◽  
Lihui Zheng ◽  
Gang Chen ◽  
...  

Heart Rhythm ◽  
2008 ◽  
Vol 5 (1) ◽  
pp. 37-42 ◽  
Author(s):  
Takumi Yamada ◽  
Hugh T. McElderry ◽  
Harish Doppalapudi ◽  
G. Neal Kay

Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Luigi Di Biase ◽  
Rodney Horton ◽  
Chintan Trivedi ◽  
Prasant Mohanty ◽  
Sanghamitra Mohanty ◽  
...  

Introduction: Radiofrequency catheter ablation of atrial fibrillation is performed under fluoroscopic guidance and therefore carries radiation risk exposure for the both the patient and the operator. Three-dimensional mapping systems and newer technologies to allow non-fluoroscopic catheter visualization together with intracardiac echo have reduced but not abolished the fluoroscopy exposure. We aim to demonstrate the feasibility, the safety and the efficacy of catheter ablation for atrial fibrillation without the use of fluoroscopy. Methods: A totally fluoro-less approach was developed for AF ablation at our Institution. 94 consecutive AF patients underwent zero fluoroscopy catheter ablation for atrial fibrillation. In the zero fluoroscopy cases, the fluoroscopy arm was kept far away from the patient table. Access including double trans-septal, mapping with the Carto 3 system and ablation were all performed without fluoroscopy with the use of ICE and the Carto 3 system. These 94 patients were compared with 94 control patients matched for age, sex and type of AF who underwent AF ablation by the same operator with the use of fluoroscopy. Results: Baseline characteristics were similar between fluoroless (N=94, Age=64.5 ± 10.1, 75.5% male, 48% paroxysmal) and control (N=94, Age=65.1 ± 9.9, 72.3% male, 50% paroxysmal) group. Non-PV triggers were detected and ablated in 51 (54.3%) and 56 (59.6%) patients in fluoroless and control group respectively (p=0.5). Average fluoro time in control group was 10.1 ± 4.7 minutes. Procedure duration was comparable (120.4 ± 25.8 vs. 122.2 ± 28.7, p =0.6). After the short term median follow-up of 4.5 (4 – 6.5) months, 10 (10.6 %) patients in flourless and 9 (9.6%) patients in control group experienced recurrences (p=0.8).One pericardial effusion requiring pericardiocenteis occurred in the fluoroless group. Conclusions: Our series show that zero fluoroscopy ablation of atrial fibrillation with the use of newer technologies is feasible, safe and efficacious at the short term follow up. Importantly in our series the double transeptal was performed without fluoroscopy and the ablation was not limited to the pulmonary veins only but included ablation of the posterior wall, the coronary sinus and the left atrial appendage.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Jin Li ◽  
Cheng Zheng ◽  
Zhi-Rui Liu ◽  
Jun Ma ◽  
Ge Jin ◽  
...  

Abstract Background Ventricular arrhythmias (VAs) arising from the origin above pulmonary valve lack comprehensive investigation. This study aimed to disclose the characteristics and radiofrequency catheter ablation (RFCA) outcomes for those VAs. Methods One hundred six VAs arising from the region above pulmonary valve treated with RFCA were included in this study. Results Seventy-five cases were identified in the pulmonary sinus cusps (PSCs, 32 in left sinus cusp (PLC), 15 in right (PRC), 28 in anterior (PAC)) and 31 cases were in the main stem of pulmonary artery (MSPA, 18 above PLC (LMSPA), 3 above PRC (RMSPA), 10 above PAC (AMSPA)). Compared with PSCs VAs, MSPA VAs exhibited a higher R wave amplitude in the inferior leads, a total inferior R amplitude > 5.1 mV predicting MSPA origins. LMSPA, RMSPA and AMSPA VAs resembled PLC, PRC and PAC VAs in electrocardiographic characteristics respectively. No electrophysiological differences were found between PSCs and MSPA VAs. The irrigated-up catheter and R0 Swartz long sheath were more utilized for ablation of PSCs VAs than for MSPA VAs. All these VAs were successfully eliminated by RFCA. Conclusion VAs arising from the origin above pulmonary valve were common. Based on certain electrocardiographic characteristics, they could be roughly located, which contributed to an effective RFCA.


Sign in / Sign up

Export Citation Format

Share Document