scholarly journals Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions

EP Europace ◽  
2014 ◽  
Vol 16 (5) ◽  
pp. 660-667 ◽  
Author(s):  
F. Squara ◽  
D. G. Latcu ◽  
Y. Massaad ◽  
M. Mahjoub ◽  
S.-S. Bun ◽  
...  
EP Europace ◽  
2015 ◽  
Vol 17 (6) ◽  
pp. 877-883 ◽  
Author(s):  
J.-B. le Polain de Waroux ◽  
R. Weerasooriya ◽  
K. Anvardeen ◽  
C. Barbraud ◽  
S. Marchandise ◽  
...  

2020 ◽  
Vol 47 (1) ◽  
pp. 3-9 ◽  
Author(s):  
Ziming Zhao ◽  
Xiaowei Liu ◽  
Lianjun Gao ◽  
Yutao Xi ◽  
Qi Chen ◽  
...  

We evaluated whether an irrigated contact force–sensing catheter would improve the safety and effectiveness of radiofrequency ablation of premature ventricular contractions originating from the right ventricular outflow tract. We retrospectively reviewed the charts of patients with symptomatic premature ventricular contractions who underwent ablation with a contact force–sensing catheter (56 patients, SmartTouch) or conventional catheter (59 patients, ThermoCool) at our hospital from August 2013 through December 2015. During a mean follow-up of 16 ± 5 months, 3 patients in the conventional group had recurrences, compared with none in the contact force group. Complications occurred only in the conventional group (one steam pop; 2 ablations suspended because of significantly increasing impedance). In the contact force group, the median contact force during ablation was 10 g (interquartile range, 7–14 g). Times for overall procedure (36.9 ± 5 min), fluoroscopy (86.3 ± 22.7 s), and ablation (60.3 ± 21.4 s) were significantly shorter in the contact force group than in the conventional group (46.2 ± 6.2 min, 107.7 ± 30 s, and 88.7 ± 32.3 s, respectively; P <0.001). In the contact force group, cases with a force-time integral <560 gram-seconds (g-s) had significantly longer procedure and fluoroscopy times (both P <0.001) than did those with a force-time integral ≥560 g-s. These findings suggest that ablation of premature ventricular contractions originating from the right ventricular outflow tract with an irrigated contact force–sensing catheter instead of a conventional catheter shortens overall procedure, fluoroscopy, and ablation times without increasing risk of recurrence or complications.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
T Rattanakosit ◽  
K Franke ◽  
H Marshall ◽  
T Agbaedeng ◽  
P Sanders ◽  
...  

Abstract Background Ablation index (AI) and Lesion Size Index (LSI) are novel parameters that incorporates contact force, time, and power in a weighted formula. Recent studies have shown that such indices predict lesion size and durability of pulmonary vein isolation (PVI). However, the outcomes of ablation guided by indices of force-time-power, such as PV reconnections and atrial fibrillation recurrence, have not been well characterised. Objectives To determine the association between indices of force-time-power and acute PV reconnections, procedure and fluoroscopy time and AF recurrence in patients undergoing radiofrequency PVI. Methods PUBMED and EMBASE were searched using the terms "catheter ablation" AND "Ablation index" OR "Contact force" OR "Force time integral" OR "lesion size" from inception through 22 May 2019. Studies reporting the procedure time, ablation time, fluoroscopy time, and incidence of AI acute and late reconnection and AF recurrence were included. Result  Six studies were included in this study with 530 patients, which n = 416 were paroxysmal AF and 114 non-paroxysmal AF. All procedural characteristics (procedure, radiofrequency, and fluoroscopy times) were similar between AI guided and non-AI guided ablation (p > 0.05). Two studies comparing mean PV reconnections in AI guided vs. AI Blinded. Two studies compared minimum AI in reconnected vs. non-reconnected PV segments. Acute PV segment reconnection was associated with a lower minimum AI vs. non-reconnection. In 3 studies reporting AI guided vs. AI blinded ablations, AI was associated with an increased freedom from AF after average follow-up of 12 months. Conclusions Radiofrequency ablation guided by AI/LSI was associated with lower acute PV reconnection rates and improved AF freedom after PVI. There was no difference in fluoroscopy, ablation or procedure time with the use of these novel parameters. Abstract Figure.


2010 ◽  
Vol 21 (9) ◽  
pp. 1038-1043 ◽  
Author(s):  
DIPEN C. SHAH ◽  
HENDRIK LAMBERT ◽  
HIROSHI NAKAGAWA ◽  
ARNE LANGENKAMP ◽  
NICOLAS AEBY ◽  
...  

Circulation ◽  
2018 ◽  
Vol 138 (Suppl_1) ◽  
Author(s):  
Emrie Tomaiko ◽  
Adnan Habib ◽  
Geoffrey J Orme ◽  
Wilber Su

Introduction: Post-ablation radiofrequency tissue friability has been described; however, tissue friability post cryoablation has not been well studied. We report a case of left atrial perforation with normal contact force radiofrequency ablation 22 days after initial cryoballoon ablation. Description: A 59-year-old male with persistent atrial fibrillation, severe biatrial enlargement, non-ischemic cardiomyopathy (EF of 20%), underwent initial cryoballoon pulmonary vein isolation with left atrial roof cryoablation with restoration of sinus rhythm and no complications. Patient presented 22 days later with sustained atrial flutter and heart rate over 130 bpm refractory to aggressive medical management, cardioversion, and acute on chronic congestive heart failure. Early re-ablation was performed with electrophysiology study and 3D activation map confirming ectopic atrial tachycardia foci arising from left atrial roof, anterior to the border of previously cryo-ablated region. St. Jude TactiCath™ contact force ablation catheter, was used to ablate this foci, and termination within 5 seconds of ablation was observed. Using the Force-Time Integral index to guide further ablation, the surrounding area was ablated for an additional 20 seconds at 30 W with a maximum recorded contact force throughout the procedure of 35 grams, and an average of 10-15 grams.A decrease in systolic blood pressure from 120 mmHg to 80 mmHg was noted, and intracardiac ultrasound confirmed 1.5 cm of pericardial effusion. Successful pericardiocentesis and reversal of anticoagulation was performed with ongoing bleeding, and eventual surgical intervention was required. On direct visualization during surgery, the left atrial roof perforation was confirmed, and was noted to be very friable and difficult to retain suture for repair. Patient did well post-operatively and was discharged with no recurrence of arrhythmias. Conclusions: Despite standard of care monitoring, including force-time integral index and contact-sensing catheters, atrial perforation occurred likely due to increased tissue friability post initial cryoablation. The optimal timing for repeat ablation is not completely understood, and extreme caution and avoidance of early re-ablation risk is prudent.


1987 ◽  
Vol 60 (6) ◽  
pp. 797-803 ◽  
Author(s):  
H Suga ◽  
Y Goto ◽  
T Nozawa ◽  
Y Yasumura ◽  
S Futaki ◽  
...  

Author(s):  
A. De Haan ◽  
J. E. Van Doorn ◽  
P. A. Huijing ◽  
R. D. Woittiez ◽  
H. G. Westra

Sign in / Sign up

Export Citation Format

Share Document