Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag Module of the CARTO 3 System) with contact force-time integral during pulmonary vein isolation for atrial fibrillation

2016 ◽  
Vol 47 (2) ◽  
pp. 245-252 ◽  
Author(s):  
Yasuo Okumura ◽  
Ichiro Watanabe ◽  
Kazuki Iso ◽  
Koichi Nagashima ◽  
Kazumasa Sonoda ◽  
...  
EP Europace ◽  
2015 ◽  
Vol 17 (6) ◽  
pp. 877-883 ◽  
Author(s):  
J.-B. le Polain de Waroux ◽  
R. Weerasooriya ◽  
K. Anvardeen ◽  
C. Barbraud ◽  
S. Marchandise ◽  
...  

2017 ◽  
Author(s):  
David R. Tomlinson

AbstractAims Following radiofrequency (RF) pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence mediated by recovery of pulmonary vein (PV) conduction is common. I examined whether comparative VISITAG™ (Biosense Webster Inc.) data analysis at sites showing intra-procedural recovery of PV conduction versus acutely durable ablation could inform the derivation of a more effective VISITAG™-guided contact force (CF) PVI protocol.Methods and results Retrospective analysis of VISITAG™ Module annotated ablation site data in 10 consecutive patients undergoing CF-guided PVI without active VISITAG™ guidance. Employing 2mm positional stability range and lenient CF filter (force-over-time 10%, minimum 2g), inter-ablation site distance >10-12mm, adjacent 0g-minimum CF and short RF duration (3-5s) were associated with intra-procedural recovery of PV conduction. A VISITAG™-guided CF PVI protocol was derived employing ≤6mm inter-ablation site distances, minimum target ablation site duration ≥9s / force time integral (FTI) 100gs and 100% 1g-minimum CF filter. Seventy-two consecutive VISITAG™-guided CF PVI procedures were then undertaken using this protocol, with PVI achieved in all utilising 23.8[8.4] minutes total RF (30W, 48°C, 17ml/min, continuous RF application). Following protocol completion, acute intra-procedural spontaneous / dormant recovery of PV conduction requiring touch-up RF occurred in 1.4% / 1.8% of PVs, respectively. At 14[5] months’ follow-up in all 34 patients with paroxysmal AF ≥6 months’ post-ablation, 30 (88%) were free from atrial arrhythmia, off class I/III anti-arrhythmic medication.Conclusion VISITAG™ provides means to identify and then avoid factors associated with intra-procedural recovery of PV conduction. This VISITAG™ Module-guided CF PVI protocol demonstrated excellent intra-procedural and long-term efficacy.Condensed abstract Following CF-guided PVI, retrospective VISITAG™ Module analyses permitted the identification of ablation parameters associated with intra-procedural recovery of PV conduction. The derived VISITAG™ Module-guided CF PVI protocol employed short over RF duration yet proved efficient at achieving PVI acutely, with long-term follow-up demonstrating high clinical efficacy.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Di Cori ◽  
L Segreti ◽  
G Zucchelli ◽  
S Viani ◽  
F Tarasco ◽  
...  

Abstract Background Contact force catheter ablation is the gold standard for treatment of atrial fibrillation (AF). Local tissue impedance (LI) evaluation has been recently studied to evaluate lesion formation during radiofrequency ablation. Purpose Aim of the study was to assess the outcomes of an irrigated catether with LI alghorithm compared to contact force (CF)-sensing catheters in the treatment of symptomatic AF. Methods A prospective, single-center, nonrandomized study was conducted, to compare outcomes between CF-AF ablation (Group 1) and LI-AF ablation (Group 2). For Group 1 ablation was performed using the Carto 3© System with the SmartTouch SF catheter and, as ablation target, an ablation index value of 500 anterior and 400 posterior. For Group 2, ablation was performed using the Rhythmia™ System with novel ablation catheter with a dedicated algorithm (DirectSense) used to measure LI at the distal electrode of this catheter. An absolute impedance drop greater than 20Ω was used at each targeted. According to the Close Protocol, ablation included a point by point pulmonary vein isolation (PVI) with an Inter-lesion space ≤5 mm in both Groups. Procedural endpoint was PVI, with confirmed bidirectional block. Results A total of 116 patients were enrolled, 59 patients in Group 1 (CF) and 57 in Group 2 (LI), 65 (63%) with a paroxismal AF and 36 (37%) with a persistent AF. Baseline patients features were not different between groups (P=ns). LI-Group showed a comparable procedural time (180±89 vs 180±56, P=0.59) but with a longer fluoroscopy time (20±12 vs 13±9 min, P=0.002). Wide antral isolation was more often observed in CF-Group (95% vs 80%, P=0.022), while LI-Group 2 required frequently additional right or left carina ablation (28% vs 14%, P=0.013). The mean LI was 106±14Ω prior to ablation and 92.5±11Ω after ablation (mean LI drop of 13.5±8Ω) during a median RF time of 26 [19–34] sec for each ablation spot. No steam pops or complications during the procedures were reported. The acute procedural success was 100%, with all PVs successfully isolated in all study patients. Regarding safety, only minor vascular complications were observed (5%), without differences between groups (p=0.97). During follow up, 9-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 86% in Group 1 and 75% in Group 2 (P=0.2). Conclusions An LI-guided PV ablation strategy seems to be safe and effective, with acute and mid-term outcomes comparable to the current contact force strategy. LI monitoring could be a promising complementary parameter to evaluate not only wall contact but also lesion formation during power delivery. Procedural Outcomes Funding Acknowledgement Type of funding source: None


PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0257050
Author(s):  
Nándor Szegedi ◽  
Zoltán Salló ◽  
Péter Perge ◽  
Katalin Piros ◽  
Vivien Klaudia Nagy ◽  
...  

Introduction Our pilot study aimed to evaluate the role of local impedance drop in lesion formation during pulmonary vein isolation with a novel contact force sensing ablation catheter that records local impedance as well and to find a local impedance cut-off value that predicts successful lesion formation. Materials and methods After completing point-by-point radiofrequency pulmonary vein isolation, the success of the applications was evaluated by pacing along the ablation line at 10 mA, 2 ms pulse width. Lesions were considered successful if loss of local capture was achieved. Results Out of 645 applications, 561 were successful and 84 were unsuccessful. Compared to the unsuccessful ablation points, the successful applications were shorter (p = 0.0429) and had a larger local impedance drop (p<0.0001). There was no difference between successful and unsuccessful applications in terms of mean contact force (p = 0.8571), force-time integral (p = 0.0699) and contact force range (p = 0.0519). The optimal cut-point for the local impedance drop indicating successful lesion formation was 21.80 Ohms on the anterior wall [AUC = 0.80 (0.75–0.86), p<0.0001], and 18.30 Ohms on the posterior wall [AUC = 0.77 (0.72–0.83), p<0.0001]. A local impedance drop larger than 21.80 Ohms on the anterior wall and 18.30 Ohms on the posterior wall was associated with an increased probability of effective lesion creation [OR = 11.21, 95%CI 4.22–29.81, p<0.0001; and OR = 7.91, 95%CI 3.77–16.57, p<0.0001, respectively]. Conclusion The measurement of the local impedance may predict optimal lesion formation. A local impedance drop > 21.80 Ohms on the anterior wall and > 18.30 Ohms on the posterior wall significantly increases the probability of creating a successful lesion.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
D De Campos ◽  
L Puga ◽  
P Sousa ◽  
N Antonio ◽  
L Elvas

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Ablation Index (AI) software has been associated with better freedom from atrial arrhythmias after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF). There is conflicting data regarding the relationship between high sensitivity cardiac Troponin I (Hs-cTnI) and arrhythmia recurrence. The objective was to evaluate the impact of AI on Hs-cTnI level and on ablation effectiveness quotient (AEQ) and to assess if these markers are predictors of arrhythmia recurrence.  Methods Prospective observational study of consecutive patients referred for PVI for paroxysmal AF ablation from October 2017 to June 2018 according to a pre-specified AI protocol. Procedural endpoints and 2-year follow-up outcomes were assessed and compared to a retrospective cohort of conventional PVI contact-force-guided group .  Results A total of 56 patients were included: 29 patients the AI group and 27 patients in the control group. The mean age was 60.5 ± 10.3 years, 48% males. Left ventricular ejection fraction (60 ± 6 % AI vs 61 ± 5 % control, P = 0.07) and left atrium diameter (43 ± 7 mm AI vs 44 ± 6 mm control, P = 0.58) were comparable between groups. First-pass isolation was shown to be higher in the AI group (79% AI vs 44%, p= 0.01). Mean number of radiofrequency applications was lower in the AI group (93 ± 24 vs 111 ± 30, P = 0.02). Average contact-force was similar between groups (17.6 ± 4.1 g vs 22.6 ± 10.7 g, P =0.166). Patients that performed PVI guided by the AI had lower Hs-cTnI (1815 ± 1146 ng/L vs 3274 ± 1696 ng/L, p &lt; 0.001) and lower AEQ (1.01 ± 0.7 ng/L/s vs 1.51 ± 0.7 ng/L/s, P = 0.011) compared to patients in the control group. During a mean follow-up of 26 ± 11 months, AF recurrence was documented in 10.3% of patients in the AI group and 22.2% in the control group (P = 0.223). Neither Hs-cTnI nor AEQ levels were predictors of arrhythmia recurrence.  Conclusions These data suggest that AI-guided catheter ablation is associated with reduced levels of of Hs-cTnI and AEQ. Neither Hs-cTnI and AEQ should be used to predict arrhythmia recurrence. Abstract Figure.


2020 ◽  
Vol 13 (9) ◽  
Author(s):  
Zak Loring ◽  
DaJuanicia N. Holmes ◽  
Roland A. Matsouaka ◽  
Anne B. Curtis ◽  
John D. Day ◽  
...  

Background: Catheter ablation is an increasingly used treatment for symptomatic atrial fibrillation (AF). However, there are limited prospective, nationwide data on patient selection and procedural characteristics. This study describes patient characteristics, techniques, treatment patterns, and safety outcomes of patients undergoing AF ablation. Methods: A total of 3139 patients undergoing AF ablation between 2016 and 2018 in the Get With The Guidelines-Atrial Fibrillation registry from 24 US centers were included. Patient demographics, medical history, procedural details, and complications were abstracted. Differences between paroxysmal and patients with persistent AF were compared using Pearson χ 2 and Wilcoxon rank-sum tests. Results: Patients undergoing AF ablation were predominantly male (63.9%) and White (93.2%) with a median age of 65. Hypertension was the most common comorbidity (67.6%), and patients with persistent AF had more comorbidities than patients with paroxysmal AF. Drug refractory, paroxysmal AF was the most common ablation indication (class I, 53.6%) followed by drug refractory, persistent AF (class I, 41.8%). Radiofrequency ablation with contact force sensing was the most common ablation modality (70.5%); 23.7% of patients underwent cryoballoon ablation. Pulmonary vein isolation was performed in 94.6% of de novo ablations; the most common adjunctive lesions included left atrial roof or posterior/inferior lines, and cavotricuspid isthmus ablation. Complications were uncommon (5.1%) and were life-threatening in 0.7% of cases. Conclusions: More than 98% of AF ablations among participating sites are performed for class I or class IIA indications. Contact force-guided radiofrequency ablation is the dominant technique and pulmonary vein isolation the principal lesion set. In-hospital complications are uncommon and rarely life-threatening.