Rapid Screening of Pharmaceuticals by Thin-Layer Chromatography: Analysis of Essential Drugs by Visual Methods

1995 ◽  
Vol 78 (1) ◽  
pp. 41-49 ◽  
Author(s):  
Allen S Kenyon ◽  
Paul E Flinn ◽  
Thomas P Layloff

Abstract A method for rapidly screening pharmaceuticals by thin-layer chromatography has been designed for use in areas with limited resources and by operators with limited training. An apparatus for performing the analysis in a plastic bag under equilibrium conditions was designed. Results can be reproduced by different operators and in different locations. The analysis can be performed without electricity or in a remote area, away from a laboratory. It is especially suited for field use in developing countries. The method is low cost, maintenance-free, fast, and reliable; it also uses limited volumes of solvents. The analyses can be performed without weighing if reference materials can be supplied in tablet form, provided the drug content is listed and only one unit is required for each analysis. All procedures were developed for the analysis of drugs from a partial list of essential drugs established by the World Health Organization. Three drugs were selected and prepared in the form of reference tablets. Comparisons with the analyses of the drugs in standard dosage forms were made by using reference tablets and primary USP standards. Comparable results were obtained, proving that the screening process can be conducted by using reference tablets and without weighing either the sample or the reference. The method has been successfully demonstrated and used in Swaziland, by high school teachers in the United States, and by personnel from the Ministry of Health in Saudi Arabia. Personnel can be trained in a short time to perform screening analysis of drugs.

1964 ◽  
Vol 47 (2) ◽  
pp. 306-310
Author(s):  
H V Morley ◽  
M Chiba

Abstract Thin-layer chromatography on silica gel may be used for the determination of chlorinated pesticide residues in some plant extracts without prior cleanup, thus eliminating the possible loss of pesticides during the cleanup procedure. Rapid screening of a large number of samples is thus possible with consequent saving of time and labor. When necessary, thin-layer chromatography may be used as a prior cleanup for gas chromatography.


Author(s):  
Fatima Chibi ◽  
Halima Rchid ◽  
Wafa Arsalane ◽  
Rachid Nmila

Objective: This work aimed to screen the antioxidant activity of marine macroalgae from the Moroccan Atlantic coast (region of El Jadida). Methods: Evaluation of the antioxidant activity of different collected species, lyophilized and extracted with a solvent mixture chloroform/methanol (2/1; v/v) was conducted according to two techniques, first by thin layer chromatography (tlc) then by spectrophotometry, using a free radical 2,2-diphenyl-1-picrylhydrazyl (dpph). The sampling on a distance of 110 km allowed to harvest 86 algal species (16 brown algae, 47 red algae, 14 green algae and 9 algae being identified). Results: The analysis by thin layer chromatography reveals an antioxidant activity in nearly half of harvested algal species (52.32 %). This activity varies depending on the concentration of the extract and in function of incubation time in the presence of dpph. The monitoring of the kinetics of degradation of dpph by spectrophotometer in the presence of extracts which were active by tlc allowed to confirm the results and select the most active algal species based on the percentage of remaining dpph in the medium after 120 min of reaction: Fucus spiralis (17.02 %), Cyctoseira ericoides (12.16 %) (Phaeophyceae), and Gracilaria multipartita (36%), Halopitys incurvus (5%) (Rhodophyceae). Conclusion: The results show that the methodology adopted in this work is reliable and can be used for rapid screening of antioxidant property in plants and the species: Fucus spiralis, Cyctoseira ericoides, Gracilaria multipartita, and Halopitys incurvus can be a promising source of natural compounds endowed with high antioxidant potential.


2007 ◽  
Vol 53 (1) ◽  
pp. 85-90 ◽  
Author(s):  
Joseph H Shelton ◽  
Carol A Santa Ana ◽  
Donald R Thompson ◽  
Michael Emmett ◽  
John S Fordtran

Abstract Background: Surreptitious ingestion of laxatives can lead to serious factitious diseases that are difficult to diagnose. Most cases involve ingestion of bisacodyl or senna. Thin layer chromatography (TLC) of urine or stool is the only commercially available test for these laxatives. Such testing is considered highly reliable, but its accuracy in clinical practice is unknown. Our aim was to evaluate the reliability of TLC laxative testing by a clinical reference laboratory in the United States. Methods: Diarrhea was induced in healthy volunteers by ingestion of bisacodyl, senna, or a control laxative (n = 11 for each laxative group). Samples of urine and diarrheal stool were sent in blinded fashion to the clinical reference laboratory for bisacodyl and senna analysis. Results: TLC testing for bisacodyl-induced diarrhea revealed a sensitivity of 73% and specificity of 91% when urine was tested and sensitivity and specificity of 91% and 96%, respectively, when stool was analyzed. When diarrhea was induced by senna, the TLC assay for senna failed to identify even a single urine or stool specimen as positive (zero% sensitivity). Conclusions: Considering the expected prevalence of surreptitious laxative abuse in patients with chronic idiopathic diarrhea (2.4%–25%, depending on the clinical setting), TLC of urine or stool for bisacodyl by this reference laboratory would often produce misleading results, and testing for senna would have no clinical value. The major problems are false-positive tests for bisacodyl and false-negative tests for senna.