scholarly journals Liquid Chromatographic Determination of Thalidomide in Tablets, Capsules, and Raw Materials

1997 ◽  
Vol 80 (4) ◽  
pp. 767-774 ◽  
Author(s):  
John C Reepmeyer ◽  
Don C Cox

Abstract A simple, isocratic liquid chromatographic method for assay of thalidomide in tablets, capsules, and raw materials was developed. The method uses a Nova-Pak octadecylsilane bonded-phase column (150 × 3.9 mm, 4 μm particle size), a mobile phase of acetonitrile-water (15 + 85), a flow rate of 1 mL/min, detection at 237 nm, and phenacetin as internal standard. Phosphoric acid was used in preparation of sample solutions to inhibit thalidomide hydrolysis. Assays ranged from 99.3 to 100.4% in raw materials from 4 manufacturers, from 79.7 to 104.8% in tablets from 7 manufacturers, and from 75.3 to 102.6% in capsules from 4 manufacturers. Assay method precisions for triplicate analyses on 5 days were 0.30% for tablets, 0.22% for capsules, and 0.22% for raw materials. Recovery from simulated tablet formulations was 100%. The method has been used to analyze individual tablets and capsules for determination of content uniformity.

1993 ◽  
Vol 76 (5) ◽  
pp. 962-965
Author(s):  
Normand Beaulieu ◽  
Susan J Graham ◽  
Edward G Lovering

Abstract A liquid chromatographic method has been developed for the determination of glyburide and 3 known related compounds in drug raw materials. The lower limit of quantitation of the related compounds is about 0.02%. Evaluation of 9 drug raw materials revealed total impurities ranging from 0.17 to 0.65%. The relative standard deviation of the assay method is <1%.


1994 ◽  
Vol 77 (6) ◽  
pp. 1447-1453 ◽  
Author(s):  
Pauline M Lacrok ◽  
Norman M Curran ◽  
Wing-Wah Sy ◽  
Dennis K J Goreck ◽  
Pierre Thibault ◽  
...  

Abstract A liquid chromatographic method for the determination of amiodarone hydrochloride and 10 related compounds in drug raw material and for assay of drug in tablets was developed. The method specifies a 3 jxm Hypersil nitrile column (150 × 4.6 mm), a mobile phase of 1 + 1 acetonitrile–ammonium acetate buffer (0.1 M adjusted to pH 6.0 with 0.1 M acetic acid), a flow rate of 1 mL/min, and detection at 240 nm. The lower limit of quantitation of the related compounds is 0.02% or less. Drug contents in 2 raw material samples were 100.1 and 99.9% and ranged from 98.2 to 99.4% in 3 tablet formulations. Impurity levels in 2 samples of raw material from different manufacturers were ca 0.4%. The presence of 3 of the known related compounds in these samples was confirmed by liquid chromatographymass spectrometry. The method applied to raw materials was evaluated by a second laboratory and found to be satisfactory.


1985 ◽  
Vol 68 (3) ◽  
pp. 545-546
Author(s):  
Michael Tsougros

Abstract A stability indicating liquid chromatographic method for the determination of diazepam in tablets was collaboratively studied by 6 laboratories. The method uses a Cig reverse phase column, a methanolwater mobile phase, p-tolualdehyde as the internal standard, and photometric detection at 254 nm. The collaborators were supplied with a synthetic tablet powder and 3 commercial tablet samples. The mean recovery of diazepam from the synthetic tablet powder was 100.2%. For all samples analyzed, the coefficient of variation was < 1.5%. The method has been adopted official first action.


1983 ◽  
Vol 66 (4) ◽  
pp. 909-912 ◽  
Author(s):  
Steven P Swanson ◽  
Venkatachalam Ramaswamy ◽  
Val R Beasley ◽  
William B Buck ◽  
Harold H Burmeister

Abstract The gas-liquid chromatographic method for the determination of T-2 toxin in plasma is described. The toxin is extracted with benzene, washed with aqueous sodium hydroxide, and chromatographed on a small Florisil column; the heptafluorobutyryl derivative is prepared by reaction with heptafluorobutyrylimidazole. The T-2 HFB derivative is chromatographed onOV-1 at 230°C and measured with an electron capture detector. Iso-T-2, an isomer of T-2 toxin, is added to samples as an internal standard before extraction. Recoveries averaged 98.0 ± 5.5% at levels ranging from 50 to 1000 ng/m L. The limit of detection is 25 ng/mL.


1985 ◽  
Vol 68 (3) ◽  
pp. 586-589
Author(s):  
Stephen C Slahck

Abstract A liquid chromatographic method for the determination of triadimefon (Bayleton™) in triadimefon technical and formulated products has been developed and subjected to a collaborative study with 7 participating collaborators. Formulations were extracted with mobile solvent and analyzed by normal phase chromatography, with 4-chlorophenyl sulfoxide as an internal standard. Collaborators were furnished with standards and samples of technical products, 50% wettable powders, and 25% wettable powders for analysis. Coefficients of variation of the values obtained on these samples were 1.42, 0.82, and 1.05%, respectively. The method has been adopted official first action.


1988 ◽  
Vol 71 (3) ◽  
pp. 523-525 ◽  
Author(s):  
Ella S Walker

Abstract A simple and rapid liquid chromatographic method is described for the qualitative and quantitative determination of carbamazepine in tablet composites and individual tablets, using the internal standard technique. Analyses were performed on a C-18 reverse-phase column with tetrahydrofuran-methanol-water (8 + 37 + 55) as the mobile phase. A linear relationship was obtained between detector responses at 254 nm and amounts of carbamazepine injected ranging from 0.2 to 1.7 ng. The coefficient of variation for 10 consecutive injections of a standard preparation was 0.4%. Recoveries of carbamazepine from 100 and 200 mg tablets averaged 101.4 and 99.7%, respectively. Assay results for commercial tablets analyzed by the proposed method agreed favorably with those obtained by the method of USP XXI. The assay results for individual tablets indicated that deviations from the average value and the range of individual values are much wider with the compendial method than with the proposed method


1987 ◽  
Vol 70 (5) ◽  
pp. 834-836
Author(s):  
Ella S Moore

Abstract A liquid chromatographic method for the determination of coumarin anticoagulants in tablets was collaboratively studied by 7 laboratories. The method uses an octadecylsilane-bonded microparticulate column, tetrahydrofuran-methanol-water-acetic acid mobile phase, and photometric detection at 311 nm. Each collaborator received samples of warfarin sodium, phenprocoumon, and dicumarol as a synthetic composite and as commercial individual and composited tablets. Pooled average assay values for synthetic and commercial tablet samples of warfarin sodium were 101.6 and 99.5%, respectively, with a combined reproducibility SD of 2.38% (CV = 2.37%) and combined repeatability SD of 1.49% (CV = 1.49%). Pooled average (SD) assay values for dicumarol and phenprocoumon commercial samples were 98.0 (2.27) and 101.3% (4.00), respectively. The content uniformity determinations of 2 mg warfarin sodium and 25 mg dicumarol tablets indicated average tablet contents (range) of 99.5% (91.0-116.0) and 98.0% (89.8-108.8), respectively. The method has been approved interim official first action


1982 ◽  
Vol 28 (10) ◽  
pp. 2143-2148 ◽  
Author(s):  
P M Edelbroek ◽  
E J de Haas ◽  
F A de Wolff

Abstract To study correlations between the concentrations, in serum, of amitriptyline and its most important metabolites with clinical response in patients, we developed a "high-performance" liquid-chromatographic method for routine determination of amitriptyline, nortriptyline, total 10-hydroxy-amitriptyline, desmethylnortriptyline, and E(trans)- and Z(cis)-10-hydroxynortriptyline. These compounds are extracted from 1 mL of alkalinized serum into hexane/isoamyl alcohol (99/1 by vol). Perazine is the internal standard. To minimize irreversible adsorption of the drugs onto the glassware, 5 micrograms of maprotiline is added to the organic phase just before evaporation. After a 10-min resolution on a silica column eluted with acetonitrile/methanol/NH4OH (1 mol/L), absorbance is measured at 240 nm. Only chlorimipramine, doxepin, procainamide, and N-acetylprocainamide may interfere with assay of the compounds that probably are therapeutically relevant: amitriptyline, nortriptyline, and E-10-hydroxynortriptyline. Uremia, lipemia, and icterus also do not affect the analysis.


1984 ◽  
Vol 67 (3) ◽  
pp. 497-499
Author(s):  
Stephen C Slahck ◽  
◽  
J B Audino ◽  
O O Bennett ◽  
B D Folsom ◽  
...  

Abstract A liquid chromatographic method for the determination of propoxur in technical and formulated products has been subjected to a collaborative study with 8 participating collaborators. Formulations are extracted with acetonitrile and analyzed by reverse phase chromatography, with n-butyrophenone as an internal standard. Collaborators were furnished with samples of technical, 70% wettable powder, 1.5 emulsifiable, and 2% bait. Coefficient of variation values obtained on the 4 samples were 0.34, 0.68, 3.25, and 5.41%, respectively. The method has been adopted official first action.


1986 ◽  
Vol 69 (5) ◽  
pp. 908-911
Author(s):  
Peter L Carter ◽  
Keith C Overton ◽  
◽  
P G Baker ◽  
O O Bennett ◽  
...  

Abstract A liquid chromatographic method for determination of bendiocarb in technical materials and wettable powders was tested by 12 collaborators. Bendiocarb is dissolved in acetonitrile containing 0.1% propiophenone as internal standard. This solution is analyzed on a liquid chromatograph utilizing a reverse phase (C18) column. The compound is detected at 254 nm and peak area is used for quantitation. The 3 different materials studied contained 20, 80, and nominally 100% bendiocarb. Each was examined in duplicate to provide the necessary matched pairs. Collaborators approved of the ease and simplicity of the method and, in particular, the way the method can be applied to automatic injection assemblies. The statistical data show acceptable precision of the method: Reproducibility coefficients of variation were 20% material, 2.04%; 80% material, 1.02%; and nominal 100% material (technical product), 0.64%. The method has been adopted official first action.


Sign in / Sign up

Export Citation Format

Share Document