scholarly journals Disposable Screen-Printed Electrode Coupled with Recombinant Drosophila melanogaster Acetylcholinesterase and Multiwalled Carbon Nanotubes for Rapid Detection of Pesticides

2011 ◽  
Vol 94 (1) ◽  
pp. 307-312 ◽  
Author(s):  
Zhuzhao Tang ◽  
Haode Chen ◽  
Shiping Song ◽  
Chunhai Fan ◽  
Dabing Zhang ◽  
...  

Abstract Recombinant Drosophila melanogaster acetylcholinesterase (R-DmAChE), multiwalled carbon nanotubes (MWCNTs), and Prussian blue have been combined for development of a three-electrode biosensor with more rapid responses and higher stability than in our previous study. A new disposable screen-printed electrode (SPE) was developed for rapid detection of organophosphate and carbamate pesticides. After optimization, 10 μg MWCNT and 5 μL enzyme immobilization solution consisting of 0.2% glutaraldehyde, 0.1% Nafion®, 0.2% bovine serum albumin, 0.1 g/L MWCNT, and 1.5 mU R-DmAChE were fixed on each of the R-DmAChE/MWCNT SPEs. The LOD of this biosensor was 0.5 μg/L for pesticide standards of dichlorvos (DDV) and carbofuran. The performance of this biosensor was tested for vegetable and water samples at various spiked levels, and good stability and sensitivity were found. The obtained recoveries were from 82.6 to 110.5% for DDV at levels of 0.5–5 μg/L and 73.4 to 118.4% for carbofuran at 1–10 μg/L in lake and sea water samples, demonstrating that the proposed approach is an alternative means for rapid detection of pesticide residues and contaminants in food safety and environmental monitoring.

Water ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 2869
Author(s):  
Cecylia Wardak ◽  
Karolina Pietrzak ◽  
Małgorzata Grabarczyk

A new copper sensitive all solid-state ion-selective electrode was prepared using multiwalled carbon nanotubes-ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) nanocomposite as an additional membrane component. The effect of nanocomposite content in the membrane on the electrode parameters was investigated. The study compares, among others, detection limits, sensitivity, and the linearity ranges of calibration curves. Content 6 wt.% was considered optimal for obtaining an electrode with a Nernstian response of 29.8 mV/decade. An electrode with an optimal nanocomposite content in the membrane showed a lower limit of detection, a wider linear range and pH range, as well as better selectivity and potential stability compared to the unmodified electrode. It was successfully applied for copper determination in real water samples.


Sign in / Sign up

Export Citation Format

Share Document