Robot-Assisted Stereotaxy Reduces Target Error: A Meta-Analysis and Meta-Regression of 6056 Trajectories

Neurosurgery ◽  
2021 ◽  
Vol 89 (Supplement_2) ◽  
pp. S79-S79
Author(s):  
Lucas R Philipp ◽  
Caio M Matias ◽  
Sara Thalheimer ◽  
Shyle H Mehta ◽  
Ashwini Sharan ◽  
...  
Neurosurgery ◽  
2020 ◽  
Author(s):  
Lucas R Philipp ◽  
Caio M Matias ◽  
Sara Thalheimer ◽  
Shyle H Mehta ◽  
Ashwini Sharan ◽  
...  

Abstract BACKGROUND The pursuit of improved accuracy for localization and electrode implantation in deep brain stimulation (DBS) and stereoelectroencephalography (sEEG) has fostered an abundance of disparate surgical/stereotactic practices. Specific practices/technologies directly modify implantation accuracy; however, no study has described their respective influence in multivariable context. OBJECTIVE To synthesize the known literature to statistically quantify factors affecting implantation accuracy. METHODS A systematic review and meta-analysis was conducted to determine the inverse-variance weighted pooled mean target error (MTE) of implanted electrodes among patients undergoing DBS or sEEG. MTE was defined as Euclidean distance between planned and final electrode tip. Meta-regression identified moderators of MTE in a multivariable-adjusted model. RESULTS A total of 37 eligible studies were identified from a search return of 2,901 potential articles (2002-2018) – 27 DBS and 10 sEEG. Random-effects pooled MTE = 1.91 mm (95% CI: 1.7-2.1) for DBS and 2.34 mm (95% CI: 2.1-2.6) for sEEG. Meta-regression identified study year, robot use, frame/frameless technique, and intraoperative electrophysiologic testing (iEPT) as significant multivariable-adjusted moderators of MTE (P < .0001, R2 = 0.63). Study year was associated with a 0.92-mm MTE reduction over the 16-yr study period (P = .0035), and robot use with a 0.79-mm decrease (P = .0019). Frameless technique was associated with a mean 0.50-mm (95% CI: 0.17-0.84) increase, and iEPT use with a 0.45-mm (95% CI: 0.10-0.80) increase in MTE. Registration method, imaging type, intraoperative imaging, target, and demographics were not significantly associated with MTE on multivariable analysis. CONCLUSION Robot assistance for stereotactic electrode implantation is independently associated with improved accuracy and reduced target error. This remains true regardless of other procedural factors, including frame-based vs frameless technique.


2020 ◽  
Vol 03 (04) ◽  
Author(s):  
Shon Shmushkevich ◽  
Massimo Baudo ◽  
Nagla Abdel Karim ◽  
Mahmoud Morsi ◽  
Mariam Khobsa ◽  
...  

2020 ◽  
Author(s):  
Hossein Dabiriyan Tehrani ◽  
Sara Yamini

This systematic review aimed to find attitudes toward Altruistic and Game-playing love styles across individualistic and collectivistic cultures. Addressing major moderators concerning Altruistic and Game-playing love styles are the secondary objectives of this review. This review included 102 articles comprising samples from 37 countries (N = 41997). The findings of this meta-analysis show that there is a collectivistic and individualistic difference in Game-playing but not in the Altruistic love style. Collectivistic and individualistic cultures, on average, demonstrate the same perception concerning the Altruistic love style, whereas collectivistic culture shows the Game-playing love style more strongly. To explain the role of moderators in key measures, the subgroup analysis and meta-regression show that both Game-playing and Altruistic love styles decline by increasing the length of the relationship. Likewise, having children affects these love styles such that the Altruistic love style is improved, and the Game-playing love style is reduced by the presence of children in families.


Sign in / Sign up

Export Citation Format

Share Document