Study of the truncation strategy in the FPGA of a solar radio digital receiver

Author(s):  
Fabao Yan ◽  
Yang Liu ◽  
Ke Xu ◽  
Ziqian Shang ◽  
Yuanyuan Zhang ◽  
...  

Abstract Computation resource is the limiting factor in higher operational accuracy of field-programmable gate arrays (FPGAs) in solar radio digital receivers. The data truncation strategy which determines the accuracy of data is then the essential technology in the design of a receiving system. Based on the solar radio spectrometer (dual channel, 14 bit, 1.25 gigasamples per second) at the Chashan Solar Radio Observatory (CSO), this paper presents a data truncation strategy which can realize real-time solar radio observation (35–40 GHz) with high time and frequency resolution as well as a large dynamic range, and at the same time saves the computation resource to a large extent. Simulations of truncations during signal processing are carried out in MATLAB, and the best truncation mechanisms are deduced for windowing and fast Fourier transform (FFT). Using the simulation results, the best truncation strategies have been implemented in the solar radio receiver at CSO with the result that the best truncation bits for the windowing operation are [27 : 14], with an error of 2.5 × 10−4, and the best truncation bits for the FFT output are [20 : 5] with an error of 1.5 × 10−3. Compared with the processing of full-precision data, occupation of the computation resources in the FPGA can be reduced significantly. For instance, the lookup table, lookup table RAM, flip flop, and digital signal processing slices are reduced by 7.36%, 14.65%, 8.38%, and 24.94%, respectively, which guarantees broad-band real-time solar radio observations (35–40 GHz).

2019 ◽  
Vol 9 (7) ◽  
pp. 1278 ◽  
Author(s):  
Xinyu Li ◽  
Shanshan Liang ◽  
Jun Zhang

Real-time Fourier domain optical coherence tomography (FDOCT) has been widely used in clinical applications. In order to accelerate the imaging processing and display of FDOCT, an alternative lookup table-based strategy for logarithmic transformation was presented. In this paper, real-time and high-quality FDOCT imaging display of biological tissues at an A-line rate of 62 kHz was demonstrated by optimizing the logarithmic calculation.


2020 ◽  
Vol 91 (10) ◽  
pp. 104707
Author(s):  
Yinyu Liu ◽  
Hao Xiong ◽  
Chunhui Dong ◽  
Chaoyang Zhao ◽  
Quanfeng Zhou ◽  
...  

Author(s):  
Phillip V. Do ◽  
Jesse Hernandez ◽  
Zhao Lu ◽  
Danson Evan Garcia ◽  
Steve Mann

Sign in / Sign up

Export Citation Format

Share Document