Monitoring intraoperative tidal volume distribution using electrical impedance tomography during upper abdominal surgery

2010 ◽  
Vol 27 ◽  
pp. 99
Author(s):  
M. S. Schaefer ◽  
B. Bastin ◽  
U. Schmalz ◽  
V. Wania ◽  
T. A. Treschan
2021 ◽  
Vol 8 ◽  
Author(s):  
Jiajia Li ◽  
Fan Zeng ◽  
Fuxun Yang ◽  
Xiaoxiu Luo ◽  
Rongan Liu ◽  
...  

Objective: To evaluate the predictive value of electrical impedance tomography (EIT) in patients with delayed ventilator withdrawal after upper abdominal surgery.Methods: We retrospectively analyzed data of patients who were ventilated >24 h after upper abdominal surgery between January 2018 and August 2019. The patients were divided into successful (group S) and failed (group F) weaning groups. EIT recordings were obtained at 0, 5, 15, and 30 min of spontaneous breathing trials (SBTs) with SBT at 0 min set as baseline. We assessed the change in delta end-expiratory lung impedance and tidal volume ratio (ΔEELI/VT) from baseline, the change in compliance change percentage variation (|Δ(CW-CL)|) from baseline, the standard deviation of regional ventilation delay index (RVDSD), and global inhomogeneity (GI) using generalized estimation equation analyses. Receiver operating characteristic curve analyses were performed to evaluate the predictive value of parameters indicating weaning success.Results: Among the 32 included patients, ventilation weaning was successful in 23 patients but failed in nine. Generalized estimation equation analysis showed that compared with group F, the ΔEELI/VT was lower, and the GI, RVDSD, and (|Δ(CW-CL)|) were higher in group S. For predicting withdrawal failure, the areas under the curve of the ΔEELI/VT, (|Δ(CW-CL)|), and the RVDSD were 0.819, 0.918, and 0.918, and 0.816, 0.884, and 0.918 at 15 and 30 min during the SBTs, respectively.Conclusion: The electrical impedance tomography may predict the success rate of ventilator weaning in patients with delayed ventilator withdrawal after upper abdominal surgery.


2014 ◽  
Vol 14 (1) ◽  
Author(s):  
Maximilian S Schaefer ◽  
Viktoria Wania ◽  
Bea Bastin ◽  
Ursula Schmalz ◽  
Peter Kienbaum ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Xuan Song ◽  
Daqiang Yang ◽  
Maopeng Yang ◽  
Yahu Bai ◽  
Bingxin Qin ◽  
...  

Background: Pulmonary complications are common in patients after upper abdominal surgery, resulting in poor clinical outcomes and increased costs of hospitalization. Enhanced Recovery After Surgery Guidelines strongly recommend early mobilization post-operatively; however, the quality of the evidence is poor, and indicators for quantifying the effectiveness of early mobilization are lacking. This study will evaluate the effectiveness of early mobilization in patients undergoing an upper abdominal surgery using electrical impedance tomography (EIT). Specifically, we will use EIT to assess and compare the lung ventilation distribution among various regions of interest (ROI) before and after mobilization in this patient population. Additionally, we will assess the temporal differences in the distribution of ventilation in various ROI during mobilization in an effort to develop personalized activity programs for this patient population.Methods: In this prospective, single-center cohort study, we aim to recruit 50 patients after upper abdominal surgery between July 1, 2021 and June 30, 2022. This study will use EIT to quantify the ventilation distribution among different ROI. On post-operative day 1, the nurses will assist the patient to sit on the chair beside the bed. Patient's heart rate, blood pressure, oxygen saturation, respiratory rate, and ROI 1-4 will be recorded before the mobilization as baseline. These data will be recorded again at 15, 30, 60, 90, and 120 min after mobilization, and the changes in vital signs and ROI 1-4 values at each time point before and after mobilization will be compared.Ethics and Dissemination: The study protocol has been approved by the Institutional Review Board of Liaocheng Cardiac Hospital (2020036). The trial is registered at chictr.org.cn with identifier ChiCTR2100042877, registered on January 31, 2021. The results of the study will be presented at relevant national and international conferences and submitted to international peer-reviewed journals. There are no plans to communicate results specifically to participants. Important protocol modifications, such as changes to eligibility criteria, outcomes, or analyses, will be communicated to all relevant parties (including investigators, Institutional Review Board, trial participants, trial registries, journals, and regulators) as needed via email or in-person communication.


2016 ◽  
Vol 311 (1) ◽  
pp. L8-L19 ◽  
Author(s):  
Barbara Vogt ◽  
Zhanqi Zhao ◽  
Peter Zabel ◽  
Norbert Weiler ◽  
Inéz Frerichs

Patients with obstructive lung diseases commonly undergo bronchodilator reversibility testing during examination of their pulmonary function by spirometry. A positive response is defined by an increase in forced expiratory volume in 1 s (FEV1). FEV1 is a rather nonspecific criterion not allowing the regional effects of bronchodilator to be assessed. We employed the imaging technique of electrical impedance tomography (EIT) to visualize the spatial and temporal ventilation distribution in 35 patients with chronic obstructive pulmonary disease at baseline and 5, 10, and 20 min after bronchodilator inhalation. EIT scanning was performed during tidal breathing and forced full expiration maneuver in parallel with spirometry. Ventilation distribution was determined by EIT by calculating the image pixel values of FEV1, forced vital capacity (FVC), tidal volume, peak flow, and mean forced expiratory flow between 25 and 75% of FVC. The global inhomogeneity indexes of each measure and histograms of pixel FEV1/FVC values were then determined to assess the bronchodilator effect on spatial ventilation distribution. Temporal ventilation distribution was analyzed from pixel values of times needed to exhale 75 and 90% of pixel FVC. Based on spirometric FEV1, significant bronchodilator response was found in 17 patients. These patients exhibited higher postbronchodilator values of all regional EIT-derived lung function measures in contrast to nonresponders. Ventilation distribution was inhomogeneous in both groups. Significant improvements were noted for spatial distribution of pixel FEV1 and tidal volume and temporal distribution in responders. By providing regional data, EIT might increase the diagnostic and prognostic information derived from reversibility testing.