Axial Radiography of the Distal Femur to Assess Rotational Alignment in Total Knee Arthroplasty

2005 ◽  
Vol &NA; (434) ◽  
pp. 193-197 ◽  
Author(s):  
Kouichi Kanekasu ◽  
Makoto Kondo ◽  
Yoshinori Kadoya
Author(s):  
Hideki Mizu-uchi ◽  
Hidehiko Kido ◽  
Tomonao Chikama ◽  
Kenta Kamo ◽  
Satoshi Kido ◽  
...  

AbstractThe optimal placement within 3 degrees in coronal alignment was reportedly achieved in only 60 to 80% of patients when using an extramedullary alignment guide for the tibial side in total knee arthroplasty (TKA). This probably occurs because the extramedullary alignment guide is easily affected by the position of the ankle joint which is difficult to define by tibial torsion. Rotational direction of distal end of the extramedullary guide should be aligned to the anteroposterior (AP) axis of the proximal tibia to acquire optimal coronal alignment in the computer simulation studies; however, its efficacy has not been proven in a clinical setting. The distal end of the guide can be overly displaced from the ideal position when using a conventional guide system despite the alignment of the AP axis to the proximal tibia. This study investigated the effect of displacement of the distal end of extramedullary guide relative to the tibial coronal alignment while adjusting the rotational alignment of the distal end to the AP axis of the proximal tibia in TKA. A total of 50 TKAs performed in 50 varus osteoarthritic knees using an image-free navigation system were included in this study. The rotational alignment of the proximal side of the guide was adjusted to the AP axis of the proximal tibia. The position of the distal end of the guide was aligned to the center of the ankle joint as viewed from the proximal AP axis (ideal position) and as determined by the navigation system. The tibial intraoperative coronal alignments were recorded as the distal end was moved from the ideal position at 3-mm intervals. The intraoperative alignments were 0.5, 0.9, and 1.4 degrees in valgus alignment with 3-, 6-, and 9-mm medial displacements, respectively. The intraoperative alignments were 0.7, 1.2, and 1.7 degrees in varus alignment with 3-, 6-, and 9-mm lateral displacements, respectively. In conclusion, the acceptable tibial coronal alignment (within 2 degrees from the optimal alignment) can be achieved, although some displacement of the distal end from the ideal position can occur after the rotational alignment of the distal end of the guide is adjusted to the AP axis of the proximal tibia.


Arthroplasty ◽  
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Goki Kamei ◽  
Shigeki Ishibashi ◽  
Koki Yoshioka ◽  
Satoru Sakurai ◽  
Hiroyuki Inoue ◽  
...  

Abstract Background In total knee arthroplasty (TKA) using the modified gap technique, the soft-tissue balance is measured after osteotomy of the distal femur and proximal tibia (conventional bone gap). However, after osteotomy, the flexion gap size during 90° knee flexion may be larger than that observed after implantation. The tension of the lateral compartment during 90° flexion may also be reduced after osteotomy of the distal femur. We manufactured a distal femoral trial component to reproduce the condition after implantation and prior to posterior condyle osteotomy. This study aimed to evaluate the effect of the trial component on the flexion gap. Methods This prospective study included 21 consecutive patients aged 78 years with medial osteoarthritis who underwent cruciate-retaining TKA between February 2017 and March 2018. The postoperative flexion gap size and inclination during 90° flexion were compared between cases with and without the trial component. Results The mean joint gap size with the trial component (13.4 ± 0.80 mm) was significantly smaller than that without the trial component (14.7 ± 0.84 mm). The mean gap inclination angle with the trial component (3.7° ± 0.62°) was significantly smaller than that without the trial component (5.5° ± 0.78°). Conclusions In the present study, the joint gap size and medial tension were significantly reduced after the trial component had been set. Accurate measurement of the soft-tissue balance is an important factor in the modified gap technique, and this method using a distal femoral trial component can offer better outcomes than those achieved with conventional methods.


2011 ◽  
Vol 26 (2) ◽  
pp. 268-273 ◽  
Author(s):  
Hiroki Watanabe ◽  
Ryuichi Gejo ◽  
Yoshikazu Matsuda ◽  
Ichiro Tatsumi ◽  
Kazuo Hirakawa ◽  
...  

The Knee ◽  
2021 ◽  
Vol 31 ◽  
pp. 64-76
Author(s):  
Takao Kaneko ◽  
Tadashi Igarashi ◽  
Kazutaka Takada ◽  
Shu Yoshizawa ◽  
Hiroyasu Ikegami ◽  
...  

2021 ◽  
Vol 15 (1) ◽  
pp. 79-84
Author(s):  
Leelasestaporn C ◽  
Thuwapitchayanant M ◽  
Sirithanapipat P ◽  
Sa-ngasoongsong P ◽  
Ruengsilsuwit P

Sign in / Sign up

Export Citation Format

Share Document