scholarly journals P0301 / #2015: EVALUATION OF CLINICAL, LABORATORY AND VENTILATOR PARAMETERS TO PREDICT EXTUBATION OUTCOME IN MECHANICALLY VENTILATED CHILDREN

2021 ◽  
Vol 22 (Supplement 1 3S) ◽  
pp. 165-165
Author(s):  
T. Aung
2019 ◽  
Vol 37 (02) ◽  
pp. 204-209 ◽  
Author(s):  
Theodore Dassios ◽  
Emma Williams ◽  
Hemant Ambulkar ◽  
Sandeep Shetty ◽  
Ann Hickey ◽  
...  

Abstract Objectives To compare the adjusted and unadjusted-for-weight tidal volume (VT) in ventilated prematurely born infants who were successfully extubated compared with the ones who failed extubation and explore the ability of VT to predict successful extubation. Study Design This is a two-center, prospective, observational, cohort study of ventilated infants born <32 weeks of gestational age (GA) at King's College Hospital and St George's University Hospital, London, United Kingdom between February and September 2018. Expiratory VT was recorded before extubation, and extubation was considered successful if the infants were not reintubated within 72 hours. Results Fifty-six (29 male) infants with a median (interquartile range) GA of 26 (25–29) weeks were studied. The infants who successfully extubated (N = 36) had a higher GA (27 [25–30] weeks) and VT (7.2 [4.8–9.5] mL) compared with the GA (25 [24–26] weeks) and VT (4.3 [4.0–5.5] mL) of the infants who failed extubation (p = 0.002 and p = 0.001, respectively). VT/kg was not different in infants who successfully extubated compared with the ones who failed extubation (p = 0.643). Following multivariate regression, VT was associated with extubation success (adjusted p = 0.022) and GA was not (adjusted p = 0.167). A VT > 4.5 mL predicted successful extubation with 82% sensitivity and 58% specificity (area under the curve = 0.786). Conclusion Successful extubation was associated with higher unadjusted-for-weight VTs compared with failed extubation, and unadjusted VT predicted extubation outcome with moderate sensitivity and specificity.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248868
Author(s):  
Antuani Rafael Baptistella ◽  
Laura Maito Mantelli ◽  
Leandra Matte ◽  
Maria Eduarda da Rosa Ulanoski Carvalho ◽  
João Antonio Fortunatti ◽  
...  

Despite the best efforts of intensive care units (ICUs) professionals, the extubation failure rates in mechanically ventilated patients remain in the range of 5%–30%. Extubation failure is associated with increased risk of death and longer ICU stay. This study aimed to identify respiratory and non-respiratory parameters predictive of extubation outcome, and to use these predictors to develop and validate an “Extubation Predictive Score (ExPreS)” that could be used to predict likelihood of extubation success in patients receiving invasive mechanical ventilation (IMV). Derivation cohort was composed by patients aged ≥18 years admitted to the ICU and receiving IMV through an endotracheal tube for >24 hours. The weaning process followed the established ICU protocol. Clinical signs and ventilator parameters of patients were recorded during IMV, in the end phase of weaning in pressure support ventilation (PSV) mode, with inspiratory pressure of 7 cm H2O over the PEEP (positive end expiratory pressure). Patients who tolerated this ventilation were submitted to spontaneous breathing trial (SBT) with T-tube for 30 minutes. Those who passed the SBT and a subsequent cuff-leak test were extubated. The primary outcome of this study was extubation success at 48 hours. Parameters that showed statistically significant association with extubation outcome were further investigated using the receiver operating characteristics (ROC) analysis to assess their predictive value. The area under the curve (AUC) values were used to select parameters for inclusion in the ExPreS. Univariable logistic regression analysis and ROC analysis were performed to evaluate the performance of ExPreS. Patients’ inclusion and statistical analyses for the prospective validation cohort followed the same criteria used for the derivation cohort and the decision to extubate was based on the ExPreS result. In the derivation cohort, a total of 110 patients were extubated: extubation succeeded in 101 (91.8%) patients and failed in 9 (8.2%) patients. Rapid shallow-breathing index (RSBI) in SBT, dynamic lung compliance, duration of IMV, muscle strength, estimated GCS, hematocrit, and serum creatinine were significantly associated with extubation outcome. These parameters, along with another parameter—presence of neurologic comorbidity—were used to create the ExPreS. The AUC value for the ExPreS was 0.875, which was higher than the AUCs of the individual parameters. The total ExPreS can range from 0 to 100. ExPreS ≥59 points indicated high probability of success (OR = 23.07), while ExPreS ≤44 points indicated low probability of success (OR = 0.82). In the prospective validation cohort, 83 patients were extubated: extubation succeeded in 81 (97.6%) patients and failed in 2 (2.4%) patients. The AUC value for the ExPreS in this cohort was 0.971. The multiparameter score that we propose, ExPreS, shows good accuracy to predict extubation outcome in patients receiving IMV in the ICU. In the prospective validation, the use of ExPreS decreased the extubation failure rate from 8.2% to 2.4%, even in a cohort of more severe patients.


Sign in / Sign up

Export Citation Format

Share Document