Rebound Tonometer Compared With Goldmann Tonometer in Normal and Pathologic Corneas

Cornea ◽  
2007 ◽  
Vol 26 (4) ◽  
pp. 427-430 ◽  
Author(s):  
Javier Moreno-Montañés ◽  
Noelia García ◽  
Ana Fernández-Hortelano ◽  
Alfredo García-Layana
2005 ◽  
Vol 25 (5) ◽  
pp. 436-440 ◽  
Author(s):  
P. Fernandes ◽  
J. A. Diaz-Rey ◽  
A. Queiros ◽  
J. M. Gonzalez-Meijome ◽  
J. Jorge

Eye ◽  
2010 ◽  
Vol 25 (1) ◽  
pp. 50-56 ◽  
Author(s):  
J Moreno-Montañés ◽  
I Gosende ◽  
J Caire ◽  
M García-Granero

2020 ◽  
Vol 3 ◽  
pp. 2
Author(s):  
Sanjay Mishra ◽  
Ashok Kumar

Objective: The objective of the study was to compare the posture-induced intraocular pressure (IOP) changes in primary angle-closure glaucoma (PACG) with or without glaucoma medications, and healthy control eyes with normal IOPs in Indian subjects. Materials and Methods: The IOP was measured in the sitting position and the supine position after 10, 20, and 30 min with a rebound tonometer. Results: Twenty-five patients with PACG and 30 controls with normal IOPs were studied. The IOP in the sitting position measured with the rebound tonometer was 13.8 + 3.2 mm Hg in eyes with PAC, and 12.9 + 2.9 mm Hg in eyes with normal IOPs. The IOP increased to 14.4 mm Hg, 16.8 mm Hg, and 18.9 mm Hg at 10 min, 20 min, and 30 min in PACG subjects. In normal age-matched controls, the IOP increased to 13.4 mm Hg, 14.9 mm Hg, and 17.8 mm Hg at 10 min, 20 min, and 30 min, respectively, but none of these differences were significant (P = 0.09; P = 0.08, P = 0.08). The mean postural IOP change from baseline was also not significant between the two groups. Only three patients were on single antiglaucoma medication with well-controlled IOP in the PACG group. Conclusions: Postural IOP changes are comparable among eyes with PACG with and without glaucoma medications, and control eyes.


2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Mahmoud Rateb ◽  
Mahmoud Abdel-Radi ◽  
Zeiad Eldaly ◽  
Mohamed Nagy Elmohamady ◽  
Asaad Noor El Din

Purpose. To evaluate the different IOP readings by Goldmann applanation tonometer (GAT), ICare rebound tonometer, and Tono-Pen in keratoconus patients after MyoRing implantation. To assess the influence of central corneal thickness (CCT) and thinnest corneal location (TCL) on IOP measurements by different tonometers. Setting. Prospective observational study was conducted in two private centers in Egypt from February 2015 to November 2016. Methods. Seventeen eyes of 10 patients suffering from keratoconus and who underwent MyoRing implantation were recruited. All subjects underwent GAT, ICare, and Tono-Pen IOP measurements in random order. Central corneal thickness and thinnest corneal location were assessed by Pentacam. Difference in mean in IOP readings was assessed by T-test. Correlation between each pair of devices was evaluated by Pearson correlation coefficient. The Bland–Altman analysis was used to assess intertonometer agreement. Results. Seventeen eyes (10 patients) were evaluated. The mean IOP reading was 13.9 ± 3.68, 12.41 ± 2.87, and 14.29 ± 1.31 mmHg in GAT, ICare, and Tono-Pen group, respectively. There was a significant difference between IOP readings by GAT/ICare and Tono-Pen/ICare (p value: 0.032 and 0.002, respectively) with no significant difference between GAT/Tono-Pen (p value: 0.554). Mean difference in IOP measurements between GAT/ICare was 1.49 ± 2.61 mmHg, Tono-Pen/ICare was 1.89 ± 2.15 mmHg, and GAT/Tono-Pen was −0.39 ± 2.59 mmHg. There was no significant correlation between the difference in IOP readings among any pair of devices and CCC or TCL. The Bland–Altman analysis showed a reasonable agreement between any pair of tonometers.


2021 ◽  
Author(s):  
Kamolchanok Kerdchuchuen ◽  
Kingkarn Samathayanon ◽  
Pitchapa Phientong ◽  
Suprapha Chattraphirat ◽  
Orapun Jaturakan ◽  
...  

2004 ◽  
Vol 81 (8) ◽  
pp. 601-605 ◽  
Author(s):  
ANDREW K. C. LAM ◽  
RUFINA CHAN ◽  
CHIN-HANG LAM

2016 ◽  
Vol 46 (8) ◽  
pp. 1466-1471 ◽  
Author(s):  
Flor Diana Yokoay Claros Chacaltana ◽  
João Antonio Tadeu Pigatto ◽  
Ione Terezinha Denardin

ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP) of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old), Group II (20 and 34 months) and Group III (37 and 135 months). Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h). Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47±0.581mmHg, 2.47±0.581mmHg and 2.51±0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.


2015 ◽  
Vol 56 (1) ◽  
pp. 93
Author(s):  
Kyoung Lae Kim ◽  
Ka Young Lee ◽  
Young Cheol Yoo

2015 ◽  
Vol 24 (7) ◽  
pp. 527-532 ◽  
Author(s):  
Javier Moreno-Montañés ◽  
José M. Martínez-de-la-Casa ◽  
Alfonso L. Sabater ◽  
Laura Morales-Fernandez ◽  
Cristina Sáenz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document