Early Response Assessed by Contrast-Enhanced Ultrasound in Breast Cancer Patients Undergoing Neoadjuvant Chemotherapy

2018 ◽  
Vol 34 (2) ◽  
pp. 84-87
Author(s):  
Ting Dong
2021 ◽  
pp. 153537022110493
Author(s):  
Yan Zheng ◽  
Lin Wang ◽  
Xiu Han ◽  
Lin Shen ◽  
Chen Ling ◽  
...  

Plasma cell mastitis is a benign suppurative disease of the breast, lack of specific clinical manifestations, which is easy to be misdiagnosed and mistreated, often confused with mastitis, breast cancer (BC), and other diseases. Thus, we aimed to establish a combined model of promoting diagnostic accuracy of plasma cell mastitis by contrast-enhanced ultrasound (CEUS) patterns and routine blood cell analysis. Eighty-eight plasma cell mastitis, 91 breast cancer, and 152 other benign breast diseases’ patients grouped according to pathological diagnosis underwent CEUS and blood cell analysis examination; 100 healthy female donors were involved. All the plasma cell mastitis and breast cancer patients presented hyperenhancement of CEUS breast lesions compared with others. The majority of plasma cell mastitis (65/88) showed perfusion defect of CEUS patterns with smooth edge (56/65) and multiple lesions (49/65); in contrast, fewer breast cancer patients (30/91) displayed perfusion defect. White blood cell count (WBC), neutrophils, and neutrophils/lymphocytes ratio of blood cell analysis in plasma cell mastitis patients increased significantly compared with other patients ( P < 0.0001). Combining perfusion defect of CEUS patterns and WBC yielded an area under the receiver operating characteristic curve of 0.831, higher than single 0.720 and 0.774, respectively. The cut-off value of WBC (7.28 × 109/L) helped remaining 65.2% (15/23) atypical cases to be correctly diagnosed as plasma cell mastitis, not misdiagnosed as breast cancer. In conclusion, CEUS presented a clear perfusion defect pattern of plasma cell mastitis lesion for the first time. A precise WBC by routine blood cell analysis test can assist CEUS examination in the differential diagnosis of plasma cell mastitis and breast cancer. It is a promised combination for laboratory diagnostic of PCM.


2016 ◽  
Vol 58 (4) ◽  
pp. 394-402 ◽  
Author(s):  
Ariel Saracco ◽  
Botond K Szabó ◽  
Ervin Tánczos ◽  
Jonas Bergh ◽  
Thomas Hatschek

Background One of the big challenges in onco-radiology is to find a reliable imaging method that may predict early response during the first cycles of any neoadjuvant chemotherapy. Purpose To evaluate the use of real-time harmonic contrast-enhanced ultrasound (CEUS) in predicting early response in breast cancer tumors under neoadjuvant chemotherapy (NAC) treatment. Material and Methods Nineteen consecutive patients with invasive breast cancer were evaluated with a bolus dose of 2.4 mL contrast agent using CEUS, before and after two cycles of epirubicin and docetaxel. The lognormal function was used for quantitative analysis of kinetic data to evaluate early response. Results There was statistically significant difference in time-to-peak ( tp) between responders and non-responders (two sample t-test, P = 0.027) where tp was significantly longer at the week 5 than at the baseline scan among responders when compared to non-responders. Conclusion In-flow of intravascular contrast agent in tumors is significantly slower in responders at real-time harmonic CEUS, and might be effectively used for the evaluation of early response to chemotherapy in invasive breast cancer. However, further investigations in a larger and more heterogeneous population should be performed to corroborate the reliability of the method.


Sign in / Sign up

Export Citation Format

Share Document