scholarly journals A two-stage ECG signal denoising method based on deep convolutional network

2020 ◽  
Author(s):  
Lishen Qiu ◽  
Wenqiang Cai ◽  
Jie Yu ◽  
Jun Zhong ◽  
Yan Wang ◽  
...  

AbstractElectrocardiogram (ECG) is an effective and non-invasive indicator for the detection and prevention of arrhythmia. ECG signals are susceptible to noise contamination, which can lead to errors in ECG interpretation. Therefore, ECG pretreatment is important for accurate analysis. In this paper, a method of noise reduction based on deep learning is proposed. The method is divided into two stages, and two corresponding models are formed. In the first stage, a one-dimensional U-net model is designed for ECG signal denoising to eliminate noise as much as possible. The one-dimensional DR-net model in the second stage is used to reconstruct the ECG signal and to correct the waveform distortion caused by noise removal in the first stage. In this paper, the U-net and the DR-net are constructed by the convolution method to achieve end-to-end mapping from noisy ECG signals to clean ECG signals. The ECG data used in this paper are from CPSC2018, and the noise signal is from MIT-BIH Noise Stress Test Database (NSTDB). In the experiment, the improvement in the signal-to-noise ratio SNRimp, the root mean square error decrease RMSEde, and the correlation coefficient P, are used to evaluate the performance of the network. This two-stage method is compared with FCN and U-net alone. The experimental results show that the two-stage noise reduction method can eliminate complex noise in the ECG signal while retaining the characteristic shape of the ECG signal. According to the results, we believe that the proposed method has a good application prospect in clinical practice.

2013 ◽  
Vol 25 (04) ◽  
pp. 1350042 ◽  
Author(s):  
Ying Yang ◽  
Yusen Wei

The random interpolation average (RIA) is a simple yet good denoising method. It firstly employed several times of random interpolations to a noisy signal, then applied the wavelet transform (WT) denoising to each interpolated signal and averaged all of the denoised signals to finish the denoising process. In this paper, multiple wavelet bases and the level-dependent threshold estimator were used in the RIA scheme so that it can be more suitable for the electrocardiogram (ECG) signal denoising. The synthetic ECG signal, real ECG signal and four types of noise were used to perform comparison experiments. The results show that the proposed method can provide the best signal to noise ratio (SNR) improvement in the deoising applications of the synthetic ECG signal and the real ECG signals. For the real ECG signals denoising, the average SNR improvement is 5.886 dB, while the result of the RIA scheme with single wavelet basis (RIAS), the fully translation-invariant [TI (fully)] and the WT denoising using hard thresholding [WT (hard)] are 5.577, 5.274 and 3.484 dB, respectively.


Author(s):  
Lishen Qiu ◽  
Wenqiang Cai ◽  
Miao Zhang ◽  
Wenliang Zhu ◽  
Lirong Wang

2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Dengyong Zhang ◽  
Shanshan Wang ◽  
Feng Li ◽  
Shang Tian ◽  
Jin Wang ◽  
...  

The electrocardiogram (ECG) signal can easily be affected by various types of noises while being recorded, which decreases the accuracy of subsequent diagnosis. Therefore, the efficient denoising of ECG signals has become an important research topic. In the paper, we proposed an efficient ECG denoising approach based on empirical mode decomposition (EMD), sample entropy, and improved threshold function. This method can better remove the noise of ECG signals and provide better diagnosis service for the computer-based automatic medical system. The proposed work includes three stages of analysis: (1) EMD is used to decompose the signal into finite intrinsic mode functions (IMFs), and according to the sample entropy of each order of IMF following EMD, the order of IMFs denoised is determined; (2) the new threshold function is adopted to denoise these IMFs after the order of IMFs denoised is determined; and (3) the signal is reconstructed and smoothed. The proposed method solves the shortcoming of discarding the first-order IMF directly in traditional EMD denoising and proposes a new threshold denoising function to improve the traditional soft and hard threshold functions. We further conduct simulation experiments of ECG signals from the MIT-BIH database, in which three types of noise are simulated: white Gaussian noise, electromyogram (EMG), and power line interference. The experimental results show that the proposed method is robust to a variety of noise types. Moreover, we analyze the effectiveness of the proposed method under different input SNR with reference to improving SNR ( SNR imp ) and mean square error ( MSE ), then compare the denoising algorithm proposed in this paper with previous ECG signal denoising techniques. The results demonstrate that the proposed method has a higher SNR imp and a lower MSE . Qualitative and quantitative studies demonstrate that the proposed algorithm is a good ECG signal denoising method.


2021 ◽  
Vol 11 (4) ◽  
pp. 1591
Author(s):  
Ruixia Liu ◽  
Minglei Shu ◽  
Changfang Chen

The electrocardiogram (ECG) is widely used for the diagnosis of heart diseases. However, ECG signals are easily contaminated by different noises. This paper presents efficient denoising and compressed sensing (CS) schemes for ECG signals based on basis pursuit (BP). In the process of signal denoising and reconstruction, the low-pass filtering method and alternating direction method of multipliers (ADMM) optimization algorithm are used. This method introduces dual variables, adds a secondary penalty term, and reduces constraint conditions through alternate optimization to optimize the original variable and the dual variable at the same time. This algorithm is able to remove both baseline wander and Gaussian white noise. The effectiveness of the algorithm is validated through the records of the MIT-BIH arrhythmia database. The simulations show that the proposed ADMM-based method performs better in ECG denoising. Furthermore, this algorithm keeps the details of the ECG signal in reconstruction and achieves higher signal-to-noise ratio (SNR) and smaller mean square error (MSE).


IRBM ◽  
2013 ◽  
Vol 34 (6) ◽  
pp. 362-370 ◽  
Author(s):  
M.K. Das ◽  
S. Ari

2018 ◽  
Vol 7 (4.12) ◽  
pp. 1
Author(s):  
Dr. Chhavi Saxena ◽  
Dr. Avinash Sharma ◽  
Dr. Rahul Srivastav ◽  
Dr. Hemant Kumar Gupta

Electrocardiogram (ECG) signal is the electrical recording of coronary heart activity. It is a common routine and vital cardiac diagnostic tool in which in electric signals are measured and recorded to recognize the practical status of heart, but ECG signal can be distorted with noise as, numerous artifacts corrupt the unique ECG signal and decreases it quality. Consequently, there may be a need to eliminate such artifacts from the authentic signal and enhance its quality for better interpretation. ECG signals are very low frequency signals of approximately 0.5Hz-100Hz and digital filters are used as efficient approach for noise removal of such low frequency signals. Noise may be any interference because of movement artifacts or due to power device that are present wherein ECG has been taken. Consequently, ECG signal processing has emerged as a common and effective tool for research and clinical practices. This paper gives the comparative evaluation of FIR and IIR filters and their performances from the ECG signal for proper understanding and display of the ECG signal.  


2019 ◽  
Vol 10 (3) ◽  
pp. 1626-1630
Author(s):  
Sharanya S ◽  
Sridhar PA ◽  
Poornakala J ◽  
Muppala Vasishta ◽  
Tharani U

Classification of Electrocardiogram (ECG) signals plays a significant role in the identification of the functioning of the heart. This work pertains with the ECG signals, where the classifier is developed for identification of normal or abnormal conditions of the heart. The raw ECG signals are collected from an online database (www.physioNet.org) for classification. The raw ECG signal is pre-processed for noise removal, and the frequency spectrum is analysed to compare raw and denoised ECG signal. Attributes (P, Q, R, S, T time intervals) from denoised ECG signal is analysed and classified using Convolution Neural Network (CNN). The paper reports a classification technique to differentiate ECG signals from the MIT-BIH database (arrhythmia database, arrhythmia p-wave annotations, atrial fibrillation). The CNN analyses the deviation between nominal ranges of attributes (amplitude and time interval) and classifies between the abnormality and normal ECG wave. This work provides a simple method for interpreting ECG related condition for the clinician and helps medical practitioners to make diagnostic decisions.


2013 ◽  
Vol 329 ◽  
pp. 269-273
Author(s):  
Ling Li Jiang ◽  
Ping Li ◽  
Bo Zeng

Denoising is an essential part of fault signal analysis. This paper proposes a kernel independent component analysis (KICA)-based denoising method for removing the noise from vibration signal. By introducing noise components of the observed signal, one-dimensional observed signal is extended to multi-dimensional signal. Then performing KICA on multidimensional signal, the noise in the observed signal consistent with the introduced noise will be removed that achieve the purpose of denosing. The effectiveness of the proposed method is demonstrated by the case study.


2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Yatao Zhang ◽  
Shoushui Wei ◽  
Yutao Long ◽  
Chengyu Liu

This study explored the performance of multiscale entropy (MSE) for the assessment of mobile ECG signal quality, aiming to provide a reasonable application guideline. Firstly, the MSE for the typical noises, that is, high frequency (HF) noise, low frequency (LF) noise, and power-line (PL) noise, was analyzed. The sensitivity of MSE to the signal to noise ratio (SNR) of the synthetic artificial ECG plus different noises was further investigated. The results showed that the MSE values could reflect content level of various noises contained in the ECG signals. For the synthetic ECG plus LF noise, the MSE was sensitive to SNR within higher range of scale factor. However, for the synthetic ECG plus HF noise, the MSE was sensitive to SNR within lower range of scale factor. Thus, a recommended scale factor range within 5 to 10 was given. Finally, the results were verified on the real ECG signals, which were derived from MIT-BIH Arrhythmia Database and Noise Stress Test Database. In all, MSE could effectively assess the noise level on the real ECG signals, and this study provided a valuable reference for applying MSE method to the practical signal quality assessment of mobile ECG.


Author(s):  
Vikrant Bhateja ◽  
Rishendra Verma ◽  
Rini Mehrotra ◽  
Shabana Urooj

Analysis of the Electrocardiogram (ECG) signals is the pre-requisite for the clinical diagnosis of cardiovascular diseases. ECG signal is degraded by artifacts such as baseline drift and noises which appear during the acquisition phase. The effect of impulse and Gaussian noises is randomly distributed whereas baseline drift generally affects the baseline of the ECG signal; these artifacts induce interference in the diagnosis of cardio diseases. The influence of these artifacts on the ECG signals needs to be removed by suitable ECG signal processing scheme. This paper proposes combination of non linear morphological operators for the noise and baseline drift removal. Non flat structuring elements of varying dimensions are employed with morphological filtering to achieve low distortion as well as good noise removal. Simulation outcomes illustrate noteworthy improvement in baseline drift yielding lower values of MSE and PRD; on the other hand high signal to noise ratios depicts suppression of impulse and Gaussian noises.


Sign in / Sign up

Export Citation Format

Share Document