Feedback control method for estimating the oxygen uptake rate in activated sludge systems

1999 ◽  
Vol 48 (4) ◽  
pp. 864-869 ◽  
Author(s):  
S.Y.C. Catunda ◽  
G.S. Deep ◽  
A.C. van Haandel ◽  
R.C.S. Freire
2019 ◽  
Vol 68 (11) ◽  
pp. 4493-4501 ◽  
Author(s):  
Francisco Jadilson dos Santos Silva ◽  
Sebastian Yuri C. Catunda ◽  
Carlos E. T. Dorea ◽  
Adrianus C. van Haandel ◽  
Helio Rodrigues dos Santos

2004 ◽  
Vol 50 (10) ◽  
pp. 203-212 ◽  
Author(s):  
D. Gapes ◽  
B.-M. Wilén ◽  
J. Keller

An experimental study was conducted to describe mass transfer impacts within nitrifying aggregates sourced from sequencing batch reactor (SBR) activated sludge systems. Flocculent and granular sludge with high nitrification activity was obtained in two laboratory SBR systems, supplied with a synthetic, ammonium-based feed. The flocculent biomass was fractionated using a sieving procedure, in order to obtain biomass fractions with different particle size distributions. The oxygen uptake rate (OUR) response to changes in dissolved oxygen concentration was measured under highly controlled conditions in a titrimetric and off-gas analysis (TOGA) sensor, and the results used to assess mass transfer effects. As the average particle size of the biomass increased, mass transfer limitations were found to increase significantly. Empirically fitted, apparent KS,O2 values were demonstrated to be highly dependent on particle size, and reflect the mass transfer limitations occurring in the aggregates within a given system. Such parameters thus have little to do with the actual biokinetic parameter from which they are derived. The results obtained from the TOGA sensor study were consistent with those obtained from a microelectrode study on the same nitrifying granules. Together, these studies add considerable weight to the conclusion that consideration of external and internal mass transfer limitations is vital to the accurate description of activated sludge treatment processes, particularly those with a high oxygen uptake rate.


Author(s):  
Francisco Jadilson dos Santos Silva ◽  
Euler C. T. de Macedo ◽  
Sebastian Y. C. Catunda ◽  
Carlos E. T. Dorea ◽  
Adrianus C. Van Haandel

2019 ◽  
Vol 4 (2) ◽  
pp. 24-32
Author(s):  
S.H. Tan ◽  
◽  
Jamaiatul Lailah M.J. ◽  
Aida Isma M.I. ◽  
◽  
...  

Activated sludge process is one of the effective methods in biological wastewater treatment and the impact of oxygen transfer through aeration process has the most important breakthroughs as it served as the largest consumer in the treatment. Aeration is an energy demanding process. Oxygen transfer into an activated sludge is a very challenging issue in the field of multiphase flows. Apart from the physical mass transfer phenomena between gas, liquid and solids phases, the transport mechanisms are also overlapped by time and temperature, varying microbial activity, impurity loads, adsorption and desorption processes. Oxygen uptake rate (OUR) for microbial population in the activated sludge system is important parameter to determine the amount of oxygen consumed during aerobic heterotropic biodegradation in the system. Evaluation of specific oxygen uptake rate (SOUR) and the volumetric mass transfer coefficient (KLA) of oxygen for three different wastewater treatment processes, namely conventional activated sludge (CAS), oxidation ditch (OD) and sequencing batch reactor (SBR) treating municipal wastewater in Kuala Lumpur have been carried out. In-situ and ex-situ measurement of pH, dissolved oxygen (DO), temperature, MLSS and MLVSS were carried out. In the activated sludge treatment, very low concentration of dissolved oxygen may cause the wastewater to turn septic resulting in death of bacteria or in active due to unstable anaerobic conditions. Conversely, an excessive dissolved oxygen may result to high energy and high 25 operating cost. Higher flowrate may also cause dissolved oxygen to rise, reducing the quality of sludge and slowing the denitrification process in the system. Results revealed that the OUR for SBR, OD and CAS were 9.582 mg O2 /L/hr, 10.074 mg O2 /L/hr and 13.764 mg O2 /L/hr, respectively. Low oxygen uptake rate indicates a low rate of microbial respiration. By computing the OUR, the mass transfer coefficient could be evaluated. It should be noted that among the treatment system in this study, the conventional activated sludge shows the highest mass transfer coefficient and specific oxygen uptake rate of 2.038 hr-1 and 15.605 mg O2 /g MLVSS/hr, respectively. Improving the oxygen transfer rate and reducing aeration in the system could achieve a cost-effective aeration system.


2018 ◽  
Vol 2018 (5) ◽  
pp. 304-307
Author(s):  
Tim Van Winckel ◽  
Ola Olagunju ◽  
Belinda Sturm ◽  
Siegfried E Vlaeminck ◽  
Kimberly L Jones ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document