Inrush current discrimination in power transformer differential protection using wavelet packet transform based technique

Author(s):  
Muhammad Farasat Abbas ◽  
Liu Zhiyuan ◽  
Hao Zhiguo ◽  
Zhang Guanjun
Author(s):  
Bahram Noshad

Abstract One of transient phenomena that lead to the false trip of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. This paper presents, at first, a new algorithm for three-phase power transformer differential protection considering effect of the ultra-saturation phenomenon based on Discrete Wavelet Transform (DWT). To model the ultra-saturation phenomenon, the nonlinear characteristic of the transformer core and the effect of the saturation of the current transformers are taken into account. It is assumed that the load of the transformer is a resistive and inductive load. In this algorithm, the ultra-saturation phenomenon, the external and internal faults of power transformer and the magnetic inrush current are simulated. To distinguish between these phenomena, appropriate criteria using DWT by the use of standard deviation of coefficients are presented. Also, one of the most important criteria for the digital relays is the time for making a decision. Thus, to determine the time of decision, the experimental results will be presented.


2013 ◽  
Vol 397-400 ◽  
pp. 1935-1938
Author(s):  
Yan Hong Wang

The differential protection for transformer is main protection , the unbalance current is the main factor affecting the behavior of the protection. The unbalance current caused many reasons, generally can be divided into steady state and transient state, the transient unbalance current is mainly under the circumstance of exciting inrush current, Containing a lot of harmonic component and harmonic component, based on this the paper studied the harmonic component in the application of power transformer differential protection, and through the simulation analysis.


2021 ◽  
Vol 197 ◽  
pp. 107297
Author(s):  
Lucas D. Simões ◽  
Hagi J.D. Costa ◽  
Matheus N.O. Aires ◽  
Rodrigo P. Medeiros ◽  
Flavio B. Costa ◽  
...  

2013 ◽  
Vol 732-733 ◽  
pp. 958-964
Author(s):  
Yao Zhao ◽  
Yu De Yang ◽  
Yan Hong Pan ◽  
Le Qi

The feasibility of transformer fast reenergizing with neutral point ungrounded after the external fault being removed is analyzed in this paper. By calculating overvoltage and discriminating magnetizing inrush current, it analyzes four ways to restore power of transformer and chooses the optimal strategy which is safe and time-saving. The result shows that in the case of transformer neutral point ungrounded, closing the low-voltage circuit side breaker before the high-voltage, which can effectively limit over-voltage in a safe range. The second harmonic characteristic of magnetizing waveform may disappear, while the intermittent angle characteristics are still significant. With the help of the intermittent angle principle, transformer differential protection may not misuse. The average time for each customer interruption is reduced from 40 minutes to 10 minutes and saves an hour for engineer on the way back and forth. It will greatly improve power supply reliability.