Optimal co-scheduling of HVAC control and battery management for energy-efficient buildings considering state-of-health degradation

Author(s):  
Tiansong Cui ◽  
Shuang Chen ◽  
Yanzhi Wang ◽  
Qi Zhu ◽  
Shahin Nazarian ◽  
...  
Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2427 ◽  
Author(s):  
Jin Dong ◽  
Christopher Winstead ◽  
James Nutaro ◽  
Teja Kuruganti

This study aims to develop a concrete occupancy prediction as well as an optimal occupancy-based control solution for improving the efficiency of Heating, Ventilation, and Air-Conditioning (HVAC) systems. Accurate occupancy prediction is a key enabler for demand-based HVAC control so as to ensure HVAC is not run needlessly when when a room/zone is unoccupied. In this paper, we propose simple yet effective algorithms to predict occupancy alongside an algorithm for automatically assigning temperature set-points. Utilizing past occupancy observations, we introduce three different techniques for occupancy prediction. Firstly, we propose an identification-based approach, which identifies the model via Expectation Maximization (EM) algorithm. Secondly, we study a novel finite state automata (FSA) which can be reconstructed by a general systems problem solver (GSPS). Thirdly, we introduce an alternative stochastic model based on uncertain basis functions. The results show that all the proposed occupancy prediction techniques could achieve around 70% accuracy. Then, we have proposed a scheme to adaptively adjust the temperature set-points according to a novel temperature set algorithm with customers’ different discomfort tolerance indexes. By cooperating with the temperature set algorithm, our occupancy-based HVAC control shows 20% energy saving while still maintaining building comfort requirements.


Akustika ◽  
2020 ◽  
pp. 2-7
Author(s):  
Marián Flimel

Energy-efficient buildings utilise the potential of renewable sources, among which heat pumps hold an important position. As this technology has a secondary effect on the environment through its noise immission, locations of outdoor units in the exterior should be subjected to the assessment. The present article deals with the options of placing heat pumps in the exterior and the placement assessment methods. The noise burden identification through the assessment of the time exposure is presented in the example of an in situ measurement.


2021 ◽  
pp. 100101
Author(s):  
Nikolay Aleksandrovich Tsvetkov ◽  
Aleksandr Vital'yevich Tolstykh ◽  
Andrey Nikolaevich Khutornoi ◽  
Stanislav Boldyryev ◽  
Anna Vladimirovna Kolesnikova ◽  
...  

2021 ◽  
Vol 9 (4) ◽  
pp. 105444
Author(s):  
Ilia Yarmoshenko ◽  
Georgy Malinovsky ◽  
Aleksey Vasilyev ◽  
Aleksandra Onishchenko

Sign in / Sign up

Export Citation Format

Share Document