Evaluation of influence of mineral oil immersion on dielectrical properties of silicone polymers by Thermal Analysis

Author(s):  
A. Haas ◽  
J. Kindersberger
2017 ◽  
Vol 139 (4) ◽  
Author(s):  
Richard Eiland ◽  
John Edward Fernandes ◽  
Marianna Vallejo ◽  
Ashwin Siddarth ◽  
Dereje Agonafer ◽  
...  

Complete immersion of servers in dielectric mineral oil has recently become a promising technique for minimizing cooling energy consumption in data centers. However, a lack of sufficient published data and long-term documentation of oil immersion cooling performance make most data center operators hesitant to apply these approaches to their mission critical facilities. In this study, a single server was fully submerged horizontally in mineral oil. Experiments were conducted to observe the effects of varying the volumetric flow rate and oil inlet temperature on thermal performance and power consumption of the server. Specifically, temperature measurements of the central processing units (CPUs), motherboard (MB) components, and bulk fluid were recorded at steady-state conditions. These results provide an initial bounding envelope of environmental conditions suitable for an oil immersion data center. Comparing with results from baseline tests performed with traditional air cooling, the technology shows a 34.4% reduction in the thermal resistance of the system. Overall, the cooling loop was able to achieve partial power usage effectiveness (pPUECooling) values as low as 1.03. This server level study provides a preview of possible facility energy savings by utilizing high temperature, low flow rate oil for cooling. A discussion on additional opportunities for optimization of information technology (IT) hardware and implementation of oil cooling is also included.


2021 ◽  
Author(s):  
Amirreza Niazmand ◽  
Prajwal Murthy ◽  
Satyam Saini ◽  
Pardeep Shahi ◽  
Pratik Bansode ◽  
...  

2021 ◽  
Author(s):  
Amirreza Niazmand ◽  
Prajwal Murthy ◽  
Satyam Saini ◽  
Pardeep Shahi ◽  
Pratik Bansode ◽  
...  

2019 ◽  
Vol 141 (2) ◽  
Author(s):  
Jimil M. Shah ◽  
Richard Eiland ◽  
Pavan Rajmane ◽  
Ashwin Siddarth ◽  
Dereje Agonafer ◽  
...  

The improved efficiency of mineral oil may offer simplicity in facility design compared to traditional air cooling and provide a means for cost savings. Despite its improved cooling efficiency and cost savings, a mineral oil immersion cooling technique is still not widely implemented and original equipment manufacturers are reluctant to jeopardize sales of existing air-based cooling system equipment. Only compelling physics regarding thermal performance of direct immersion cooling is not enough for data center operators. Many uncertainties and concerns persist regarding the effects of mineral oil immersion cooling on the reliability of information technology (IT) equipment both at the component and chassis level. This paper is a first attempt at addressing this challenge by reviewing the changes in physical and chemical properties of IT equipment materials like polyvinyl chloride (PVC), printed circuit board (PCB), and capacitors and characterizes the interconnect reliability of materials. The changes in properties of a mineral oil like kinematic viscosity and dielectric strength are also cited as important factors and discussed briefly. The changes in mechanical properties like elasticity, hardness, swelling, and creep are being shown in the paper for thermoplastic materials. The chemical reaction between material and mineral oil as a function of time and temperature is also conferred. The literature gathered on the subject and quantifiable data gathered by the authors provide the primary basis for this research document.


Thorax ◽  
1996 ◽  
Vol 51 (6) ◽  
pp. 652-657 ◽  
Author(s):  
I R Hussain ◽  
F P Edenborough ◽  
R S Wilson ◽  
D E Stableforth

Author(s):  
Jimil M. Shah ◽  
Syed Haider I. Rizvi ◽  
Indu Sravani Kota ◽  
Sahithi Reddy Nagilla ◽  
Dhaval Thakkar ◽  
...  

Full submersion of servers in dielectric oils offers an opportunity for significant cooling energy savings and increased power densities for data centers. The enhanced thermal properties of oil can lead to considerable savings in both the upfront and operating costs over traditional air cooling methods. Despite recent findings showing the improved cooling efficiency and cost savings of oil as a cooling fluid, this technique is still not widely adopted. Many uncertainties and concerns persist regarding the non-thermal aspects of an oil immersion cooled data center. This paper presents useful information regarding a variety of factors related to the operation of an oil cooled data center. Pertinent material property considerations such as the chemistry, flammability, material compatibility, human health effects, and sustainability of mineral oil are discussed. A general introduction as to the chemical composition and production of mineral oil is provided. A discussion of the trade-offs in thermal performance and cost of the mineral oil is presented. The dielectric nature of oils is critical to their success as a cooling fluid for electronic applications. Factors such as temperature, voltage, and age that affect this property are reviewed. Flammability of oils is a valid concern when immersing costly IT equipment and the pertinent concerns of this aspect are reviewed. The evaporation loss of oil is also mentioned as refueling and safety are important parameters in the establishment of any facility. Leeching of materials, especially plastics, is a reoccurring concern expressed regarding mineral oil immersed IT equipment. Mineral oils are by-products of petroleum refining processes and as such may bring forth sustainability concerns associated with their use and disposal. The long term stability and performance of key physical and material parameters of oils used in applications such as high voltage power are typically monitored. The similarity and implications of the longevity of oils, when used for data center applications, will be examined. Other issues related to the design, operation, and serviceability of submerged IT equipment and racks will also be addressed. Switching to an oil immersion cooled data center typically brings about several designs and operational changes compared to a typical air-cooled approach. A critical element of oil cooling often cited by opponents of the technology is the issue of serviceability of IT equipment. This paper will discuss some of the additional features a data center may need in place to help alleviate these concerns, as well as, best practices based on experience and observations by the authors. This paper also includes Cup Burner Experiment as per ISO 14520/NFPA 2001 standard to determine the minimum design concentration of fire extinguishing agent for the class B hazard of heavy mineral oil and the class C hazard of electronic equipment as a part of the safety concerns for oil cooled data centers. The visual observations of the servers after immersion in oil for 8 months are also explained for a better view of the system related issues. The discussion presented here is based primarily on literature gathered on the subject and quantifiable data gathered by the authors.


2001 ◽  
Vol 7 (S2) ◽  
pp. 148-149
Author(s):  
C.D. Poweleit ◽  
J Menéndez

Oil immersion lenses have been used in optical microscopy for a long time. The light’s wavelength is decreased by the oil’s index of refraction n and this reduces the minimum spot size. Additionally, the oil medium allows a larger collection angle, thereby increasing the numerical aperture. The SIL is based on the same principle, but offers more flexibility because the higher index material is solid. in particular, SILs can be deployed in cryogenic environments. Using a hemispherical glass the spatial resolution is improved by a factor n with respect to the resolution obtained with the microscope’s objective lens alone. The improvement factor is equal to n2 for truncated spheres.As shown in Fig. 1, the hemisphere SIL is in contact with the sample and does not affect the position of the focal plane. The focused rays from the objective strike the lens at normal incidence, so that no refraction takes place.


1952 ◽  
Vol 20 (4) ◽  
pp. 587-594 ◽  
Author(s):  
Frederick Steigmann ◽  
Hans Popper ◽  
Hattie Dyniewicz ◽  
Irene Maxwell

2012 ◽  
Vol 46 (3) ◽  
pp. 29
Author(s):  
BRUCE JANCIN
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document