Islanding detection and control of grid connected inverter

Author(s):  
M. Rukonuzzaman
2021 ◽  
Vol 19 (02) ◽  
pp. 250-259
Author(s):  
Jakson Paulo Bonaldo ◽  
Jose de Arimateia Olimpio Filho ◽  
Augusto Matheus dos Santos Alonso ◽  
Helmo Kelis Morales Paredes ◽  
Fernando Pinhabel Marafao

2019 ◽  
Vol 9 (2) ◽  
pp. 252 ◽  
Author(s):  
Ziqian Zhang ◽  
Cihan Gercek ◽  
Herwig Renner ◽  
Angèle Reinders ◽  
Lothar Fickert

This article presents an in-situ comparative analysis and power quality tests of a newly developed photovoltaic charging system for e-bikes. The various control methods of the inverter are modeled and a single-phase grid-connected inverter is tested under different conditions. Models are constituted for two current control methods; the proportional resonance and the synchronous rotating frames. In order to determine the influence of the control parameters, the system is analyzed analytically in the time domain as well as in the frequency domain by simulation. The tests indicated the resonance instability of the photovoltaic inverter. The passivity impedance-based stability criterion is applied in order to analyze the phenomenon of resonance instability. In conclusion, the phase-locked loop (PLL) bandwidth and control parameters of the current loop have a major effect on the output admittance of the inverter, which should be adjusted to make the system stable.


Solar Energy ◽  
2013 ◽  
Vol 97 ◽  
pp. 155-167 ◽  
Author(s):  
Ku Nurul Edhura Ku Ahmad ◽  
Nasrudin Abd Rahim ◽  
Jeyraj Selvaraj ◽  
Ahmad Rivai ◽  
Krismadinata Chaniago

2013 ◽  
Vol 448-453 ◽  
pp. 2191-2194
Author(s):  
Lei Zhou ◽  
Hong Da Liu ◽  
Ming Jie Chen ◽  
Nai Jun Shen

On the basis of analyzing the synthesis application of p-q (instantaneous reactive power) theory and unit vector template, a multi-functional grid-connected inverter (MFGCI) with auxiliary services on power quality enhancement in micro-grid (MG) is presented. The novel control strategy for achieving maximum benefits from these MFGCI when installed in AC MG access to 3-phase 4-wire distribution systems by isolated transformer at the point of common coupling (PCC). This kind of inverter can not only deliver the power generation of renewable energy sources (RESs), but also can perform as active power filter (APF) at their PCC as well as can improve the efficiency of inverter and decrease the hardware investment. Finally, both feasibility and effectiveness of this new topologies and control strategies of MFGCI are verified by PSCAD/EMTDC.


Sign in / Sign up

Export Citation Format

Share Document