Electrical energy consumption estimation in water distribution systems using a clustering based method

Author(s):  
Gheorghe Grigoras ◽  
Marcel Istrate ◽  
Florina Scarlatache
2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gheorghe Grigoras

The problem of optimal management of a water distribution system includes the determination of the operation regime for each hydrophore station. The optimal operation of a water distribution system means a maximum attention to assess the demands of the water, with minimum electrical energy consumption. The analysis of load profiles corresponding to a water distribution system can be the first step that water companies must make to assess the electrical energy consumption. This paper presents a new method to assess the electrical load in water distribution systems, taking into account the time-dependent evolution of loads from the hydrophore stations. The proposed method is tested on a real urban water distribution system, showing its effectiveness in obtaining the electrical energy consumption with a relatively low computational burden.


Symmetry ◽  
2019 ◽  
Vol 11 (9) ◽  
pp. 1181
Author(s):  
Mitar Jocanovic ◽  
Boris Agarski ◽  
Velibor Karanovic ◽  
Marko Orosnjak ◽  
Milana Ilic Micunovic ◽  
...  

In this multidisciplinary research, an LCA/LCC model is developed for assessing the costs, energy consumption, and greenhouse gas (GHG) emissions during the pump unit lifecycles in drinking water distribution systems (WDS). The presented methodology includes the pump, motor, and variable frequency drive monitoring as a system (pump unit), through their life-cycle stages: the manufacturing stage, the exploitation stage, and the disposal stage at the end of their life-cycle. The developed model also analyses other processes such as the maintenance, testing, and reconstruction of the pump unit. Demonstration of the presented methodology was performed using the pump unit of an operating WDS system in different scenarios, in order to illustrate the proper application of this model. The obtained results show that the application of pump units is justified in terms of energy consumption. The results also show that 93%–94% of the consumed energy and the LCC costs are related to the pump operating costs, while the rest are related to auxiliary operations. The findings show that various countries can have considerably different prices of electrical energy and different GHG emissions that depend on the source of electric energy. The implemented model incorporates some of the symmetries that are commonly found in the mathematical models of water distribution systems. Finally, the results of pump unit exploitation within the WDS have been used to show the impact of such plants on different levels of energy consumption, GHG emissions, and LCC production.


2012 ◽  
Vol 5 (1) ◽  
pp. 47-65 ◽  
Author(s):  
A. Marchi ◽  
A. R. Simpson ◽  
N. Ertugrul

Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take advantage of the demand variability and can decrease energy consumption significantly. One of the issues in using variable speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper aims to provide a comprehensive discussion about the components of WDS that incorporate variable speed pumps (including electric motors, inverters and the pumps themselves) to provide an insight of ways of increasing the system efficiency and hence to reduce energy consumption. In addition, specific attention is given to selection of motor types, sizing, duty cycle of pump (ratio of on-time and time period), losses due to installation and motor faults. All these factors affect the efficiency of motor drive/pump system.


2012 ◽  
Vol 5 (1) ◽  
pp. 15-21 ◽  
Author(s):  
A. Marchi ◽  
A. R. Simpson ◽  
N. Ertugrul

Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take advantage of the demand variability and can decrease energy consumption significantly. One of the issues in using variable speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper aims to provide a comprehensive discussion about the components of WDS that incorporate variable speed pumps (including electric motors, variable frequency drives and the pumps themselves) to provide an insight of ways of increasing the system efficiency and hence to reduce energy consumption. In addition, specific attention is given to selection of motor types, sizing, duty cycle of pump (ratio of on-time and time period), losses due to installation and motor faults. All these factors affect the efficiency of motor drive/pump system.


Sign in / Sign up

Export Citation Format

Share Document