Comparison of Harmonic Blocking Methods in Transformer Differential Protection under GIC Conditions

Author(s):  
Babak Ahmadzadeh-Shooshtari ◽  
Afshin Rezaei-Zare
2021 ◽  
Vol 197 ◽  
pp. 107297
Author(s):  
Lucas D. Simões ◽  
Hagi J.D. Costa ◽  
Matheus N.O. Aires ◽  
Rodrigo P. Medeiros ◽  
Flavio B. Costa ◽  
...  

2013 ◽  
Vol 732-733 ◽  
pp. 958-964
Author(s):  
Yao Zhao ◽  
Yu De Yang ◽  
Yan Hong Pan ◽  
Le Qi

The feasibility of transformer fast reenergizing with neutral point ungrounded after the external fault being removed is analyzed in this paper. By calculating overvoltage and discriminating magnetizing inrush current, it analyzes four ways to restore power of transformer and chooses the optimal strategy which is safe and time-saving. The result shows that in the case of transformer neutral point ungrounded, closing the low-voltage circuit side breaker before the high-voltage, which can effectively limit over-voltage in a safe range. The second harmonic characteristic of magnetizing waveform may disappear, while the intermittent angle characteristics are still significant. With the help of the intermittent angle principle, transformer differential protection may not misuse. The average time for each customer interruption is reduced from 40 minutes to 10 minutes and saves an hour for engineer on the way back and forth. It will greatly improve power supply reliability.


2015 ◽  
Vol 799-800 ◽  
pp. 1311-1315
Author(s):  
G. Igarashi ◽  
J.C. Santos

Our aim is to show some impacts on the differential protection of power transformers when using Non-Conventional Instrument Transformers associated with the IEC 61850-9-2 process bus. Described herein are a model for simulating the samples in the process bus, a proposed algorithm for differential protection of power transformers adapted from conventional differential relays so that it works according to the IEC 61850-9-2 standard, and a response analysis of the protection algorithm with the loss of the time synchronization signal in the process bus. Suggestions on parameters to be followed for safer operation of the process bus in these circumstances are also offered.


2013 ◽  
Vol 722 ◽  
pp. 282-286
Author(s):  
Hong Hua He

The microprocessor-relay protection device has gradually replaced regular simulation relay protection it is also difficult to visually determine protection device malfunction or tripping. Therefore, the use of the Mat lab toolbox to build transformer differential protection simulation model, the simulation results show that two-line ratio brake can correctly identify internal fault current, and rapidly remove fault, and the system also can provide convenient for microprocessor transformer protection.