Reference Free Ion-Selective Electrode For Sensing Potassium Ions

Author(s):  
Musafargani Sikkandhar ◽  
Yu Chen ◽  
Cheng Ming-Yuan
Biosensors ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 109
Author(s):  
Li-Da Chen ◽  
Wei-Jhen Wang ◽  
Gou-Jen Wang

This study aimed to develop simple electrochemical electrodes for the fast detection of chloride, sodium and potassium ions in human serum. A flat thin-film gold electrode was used as the detection electrode for chloride ions; a single-piece type membrane based solid-state ion-selective electrode (ISE), which was formed by covering a flat thin-film gold electrode with a mixture of 7,7,8,8-tetracyanoquinodimethane (TCNQ) and ion-selective membrane (ISM), was developed for sodium and potassium ions detection. Through cyclic voltammetry (CV) and square-wave voltammetry (SWV), the detection data can be obtained within two minutes. The linear detection ranges in the standard samples of chloride, sodium, and potassium ions were 25–200 mM, 50–200 mM, and 2–10 mM, with the average relative standard deviation (RSD) of 0.79%, 1.65%, and 0.47% and the average recovery rates of 101%, 100% and 96%, respectively. Interference experiments with Na+, K+, Cl−, Ca2+, and Mg2+ ions demonstrated that the proposed detection electrodes have good selectivity. Moreover, the proposed detection electrodes have characteristics such as the ability to be prepared under relatively simple process conditions, excellent detection sensitivity, and low RSD, and the detection linear range is suitable for the Cl−, Na+ and K+ concentrations in human serum.


2021 ◽  
Author(s):  
Li-Da Chen ◽  
Gou-Jen Wang

Abstract This study aimed to develop simple electrochemical electrodes for the fast detection of chlorine, sodium, and potassium ions in human serum. A flat thin-film gold electrode was used as the detection electrode for chloride ions; a solid-state ion-selective electrode (ISE), which was formed by covering a flat thin-film gold electrode with a mixture of 7,7,8,8-tetracyanoquinodimethane (TCNQ) and ion-selective membrane (ISM), was developed for sodium and potassium ions detection. Through cyclic voltammetry (CV) and square-wave voltammetry (SWV), the detection data can be obtained within two minutes. The linear detection ranges in the standard samples of chlorine, sodium, and potassium ions were 25–200 mM, 50–200 mM, and 2–10 mM, with the average relative standard deviation (RSD) of 0.79%, 1.65%, and 0.47% and the average recovery rates of 101%, 100%, and 96% respectively. Interference experiments using normal concentrations of Na+, K+, Cl−, Ca2+, and Mg2+ in human blood demonstrated that the proposed detection electrodes have good selectivity. Moreover, the proposed detection electrodes have characteristics such as the ability to be prepared under relatively simple process conditions, excellent detection sensitivity, and low RSD, and the detection linear range is suitable for the Cl−, Na+, and K+ concentrations in human serum.


1981 ◽  
Vol 46 (2) ◽  
pp. 368-376 ◽  
Author(s):  
Josef Veselý

Titration of sulphates with lead perchlorate employing lead ion selective electrode indication was studied using additions of various organic solvents at different pH' and ionic strength values. As the optimum emerged systems with 60-70% 1,4-dioxane, pH' 5.3-5.6. After dehydration with sodium hydroxide, dioxane must be freed from the electrode surface-oxidizing impurities by their reduction with sodium metal and subsequent distillation. The method was applied to determination of sulphates in mountain spring waters. Units of ppm can be determined; the limit of determination, however, depends considerably on the content of dioxane, total salt content in the sample, and speed of the semi-automatic titration. Lead can be determined with EDTA in concentrations down to c(Pb2+) = 5 . 10-6 mol l-1.


1986 ◽  
Vol 51 (11) ◽  
pp. 2437-2443
Author(s):  
František Kopecký ◽  
Mária Vojteková ◽  
Milan Pešák

The conventional activity of chloride ions was measured by an ion-selective electrode at 25 °C in aqueous solutions of benflurone, i.e. 5-(2-(N,N-dimethylamino)ethoxy)-7-oxo-7H-benzo(c)fluorene hydrochloride, without or with additions of KCl. These results suggest a gradual association of benflurone; the formation of a hetero-associate, (BH+)2Cl-, followed by higher associates was evaluated in the measured range up to 0.1 mol l-1.


2006 ◽  
Vol 112 (1-2) ◽  
pp. 13-18 ◽  
Author(s):  
R. Le Van Mao ◽  
N. Al-Yassir ◽  
L. Lu ◽  
N. T. Vu ◽  
A. Fortier

Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 155
Author(s):  
Yan Su ◽  
Ting Liu ◽  
Caiqiao Song ◽  
Aiqiao Fan ◽  
Nan Zhu ◽  
...  

As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.