CFD Simulation on Flow Field of a Large Flow Rate High Speed On/off Valve

Author(s):  
Qiang GAO ◽  
Yuchuan ZHU ◽  
Xiaoming CHEN ◽  
Bruno Niyomwungeri
2001 ◽  
Author(s):  
Tarek Mekhail ◽  
Zhang Li ◽  
Du Zhaohui ◽  
Willem Jansen ◽  
Chen Hanping

Abstract The PIV (Particle Image Velocimetry) technology is a brand-new technique of measuring velocity. It started in the 1980’s with the development of high-speed photography and the image processing technique of computers. This article deals with PIV applied to the study of unsteady impeller-vaneless diffuser interaction in centrifugal fen. Experiments were carried out at The Turbomachinery Laboratory of Shanghai Jiaotong University. The test rig consists of a centrifugal, shrouded impeller, diffuser and volute casing all made of plexiglass. A series of performance measurements were carried out at different speeds and different vaneless diffuser widths. PIV measurements were applied to measure the unsteady flow at the exit part of the impeller and the inlet part of the diffuser for the case of the same width vaneless diffuser. The absolute flow field is measured at medium flow rate and at maximum flow rate. It is informative to capture the whole flow field at the same instant of time, and it might be more revealing to observe the unstable flow in real time.


Complexity ◽  
2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Hengxuan Luan ◽  
Liyuan Weng ◽  
Ranhui Liu ◽  
Yuanzhong Luan ◽  
Dongmin Li

This paper describes the investigations performed to better understand two-stage rotor speed matching in a contrarotating fan. In addition, this study develops a comprehensive measuring and communication system for a contrarotating fan using ZigBee network. The investigation method is based on three-dimensional RANS simulations; the RANS equations are solved by the numerical method in conjunction with a SST turbulence model. A wireless measurement system using big data method is first designed, and then a comparison is done with experimental measurements to outline the capacity of the numerical method. The results show that when contrarotating fan worked under designed speed, performance of two-stages rotors could not be matched as the designed working condition was deviated. Rotor 1 had huge influences on flow rate characteristics of a contrarotating fan. Rotor 2 was influenced by flow rates significantly. Under large flow rate condition, the power capability of rotor 2 became very weak; under working small flow rate condition, overloading would take place to class II motor. In order to solve the performance mismatch between two stages of CRF under nondesigned working conditions, under small flow rate condition, the priority shall be given to increase of the speed of rotor 1, while the speed of rotor 2 shall be reduced appropriately; under large flow rate condition, the speed of rotor 1 shall be reduced and the speed of rotor 2 shall be increased at the same time.


Author(s):  
Zunqiang Fan ◽  
Jianfang Liu ◽  
Jingshi Dong ◽  
Jianqiao Li ◽  
Bin Jiang

2008 ◽  
Vol 74 (742) ◽  
pp. 1270-1277
Author(s):  
Fuminori MATSUYAMA ◽  
Michio SADATOMI ◽  
Akimaro KAWAHARA ◽  
Kentarou FUKAMACHI

Sign in / Sign up

Export Citation Format

Share Document