A Development of a Low-Cost 12-Lead Electrocardiogram Monitoring Device Using Android-based Smartphone

Author(s):  
Stanley Glenn E. Brucal ◽  
Jerome R. Guemo ◽  
Samboy Jim B. Montante ◽  
Carlos Angelo E. Ng ◽  
Denzel Jansen C. Wong
Author(s):  
Kathleen Mae V. Caceres ◽  
Mary Joy SA. Apetrior ◽  
Ruffa Mae S. Coldes ◽  
Andrea Pauline J. Espion ◽  
John Adrian C. Infante ◽  
...  

Author(s):  
Olalekan Kabiru Kareem ◽  
Aderibigbe Adekitan ◽  
Ayokunle Awelewa

Electric power is the bedrock of our modern way of life. In Nigeria, power supply availability, sufficiency and reliability are major operational challenges. At the generation and transmission level, effort is made to ensure status monitoring and fault detection on the power network, but at the distribution level, particularly within domestic consumer communities there are no fault monitoring and detection devices except for HRC fuses at the feeder pillar. Unfortunately, these fuses are sometimes replaced by a copper wire bridge at some locations rendering the system unprotected and creating a great potential for transformer destruction on overload. This study is focused on designing an on-site power system monitoring device to be deployed on selected household entry power cables for detecting and indicating when phase off, low voltage, high voltage, over current, and blown fuse occurs on the building’s incomer line. The fault indication will help in reducing troubleshooting time and also ensure quick service restoration. After design implementation, the test result confirms design accuracy, device functionality and suitability as a low-cost solution to power supply system fault monitoring within local communities.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Johnathan Kongoletos ◽  
Ethan Munden ◽  
Jennifer Ballew ◽  
Daniel J. Preston

AbstractVentilation, including fume hoods, consumes 40–70% of the total energy used by modern laboratories. Energy-conscious fume hood usage—for example, closing the sash when a hood is unused—can significantly reduce energy expenditures due to ventilation. Prior approaches to promote such behaviors among lab users have primarily relied on passive feedback methods. In this work, we developed a low-cost fume hood monitoring device with active feedback to alert lab users when a fume hood is left open and unused. Using data collected by the building management system, we observed a 75.6% decrease in the average sash height after installation of these “Motion and Sash Height” (MASH) alarms, which would result in a reduction roughly equal to 43% of the annual carbon emissions of a typical American vehicle, for each fume hood. The MASH alarm presented here reduced energy costs by approximately $1,159 per year, per hood, at MIT.


2019 ◽  
Vol 2 (2) ◽  
pp. 618-625 ◽  
Author(s):  
Subhankar Mandal ◽  
Anant Seth ◽  
Vikas Yadav ◽  
Srishti Kumari ◽  
Milan Kumar ◽  
...  

2019 ◽  
Vol 6 (5) ◽  
pp. 2652-2658 ◽  
Author(s):  
Jihye Bong ◽  
Omar Yasin ◽  
Vaibhav R. Vaidya ◽  
Jeongpil Park ◽  
Zachi I. Attia ◽  
...  

2017 ◽  
Author(s):  
Precious J Kilimo ◽  
Tai Le ◽  
Ngoc T Phan ◽  
Huy-Dung Han ◽  
Hoc T Hoang ◽  
...  

BACKGROUND Having mobile devices that provide patients with the ability to record and monitor the electrical activity of their heart enhances patient self-care and the early detection of irregular heartbeat (cardiac arrhythmia), yet few such devices exist in Vietnam. Challenges exist for introducing mobile electrocardiography (ECG) monitoring devices in Vietnam, including patient accessibility and affordability. A low-cost mobile ECG monitoring device designed and developed in Vietnam, which allows patients to easily measure their heart’s electrical activity and navigate recordings, may be a solution. OBJECTIVE The aim of this project is to assess the usability of the MD-Link system, a newly developed mobile handheld 1-lead ECG device, in detecting patients with irregular heartbeat. We will compare its outputs to the standard printed outputs of a 12-lead electrocardiogram generated by the Nihon Kohden Cardiofax S Electrocardiograph Model ECG-1250K. METHODS We will conduct a cross-sectional study in two stages, including the measurement of ECG signals of patients using the MD-Link and the Nihon Kohden Cardiofax S and analysis of the selected standard outputs collected from the ECG recordings of the MD-Link and the Nihon Kohden Cardiofax S. The MD-Link consists of (1) a mobile device (eg, a smartphone); (2) a lead wire with 2 disposable electrodes; and (3) an easy-to-use mobile app interface enabling the upload and accurate display of ECG recordings to patients and their clinicians. Our research team, consisting of members from Dartmouth College; the Institute of Health, Population and Development; Hanoi University of Science and Technology; and physicians and nurses from Thanh Chan Clinic, will assist in carrying out this project. RESULTS We will proceed with a publication plan that includes a project report and, ultimately, articles for peer-reviewed journals. We also hope to disseminate our work at relevant conferences to provide more coverage and exposure to the MD-Link mobile device. Recruitment and data collection were completed in January 2018. Data analysis started in February 2018 and is ongoing. Results are expected mid-2019. CONCLUSIONS At the end of this project, we will have developed and tested the MD-Link, a low-cost mobile ECG monitoring device, with some supportive comparisons to standard ECG devices commonly used in heart clinics or hospitals in Vietnam. Our long-term goal is for the MD-Link to be easily accessible, affordable, and to fit into a patient’s daily routine, thus improving the care and treatment of patients with cardiovascular diseases (CVDs). INTERNATIONAL REGISTERED REPOR RR1-10.2196/8762