Bi-directional AC-DC converter for distributed DC power system with wide bus voltage

Author(s):  
Yang Chen ◽  
Zhang Binfeng ◽  
Li Juan ◽  
Xie Shao-jun ◽  
Mao Ling
Keyword(s):  
Dc Power ◽  
Author(s):  
Jonghun Yun ◽  
Young-kwang Son ◽  
Hyung-June Cho ◽  
Seung-Ki Sul AE

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3843
Author(s):  
Sultan Sh. Alanzi ◽  
Rashad M. Kamel

This paper investigates the maximum photovoltaic (PV) penetration limits on both overhead lines and underground cables medium voltage radial distribution system. The maximum PV penetration limit is estimated considering both bus voltage limit (1.05 p.u.) and feeder current ampacity (1 p.u.). All factors affect the max PV penetration limit are investigated in detail. Substation voltage, load percentage, load power factor, and power system frequency (50 Hz or 60 Hz) are analyzed. The maximum PV penetration limit associated with overhead lines is usually higher than the value associated with the underground cables for high substation voltage (substation voltage = 1.05 and 1.04 p.u.). The maximum PV penetration limit decreases dramatically with low load percentage for both feeder types but still the overhead lines accept PV plant higher than the underground cables. Conversely, the maximum PV penetration increases with load power factor decreasing and the overhead lines capability for hosting PV plant remains higher than the capability of the underground cables. This paper proved that the capability of the 60-Hz power system for hosting the PV plant is higher than the capability of 50 Hz power system. MATLAB software has been employed to obtain all results in this paper. The Newton-Raphson iterative method was the used method to solve the power flow of the investigated systems.


2013 ◽  
Vol 385-386 ◽  
pp. 1078-1081 ◽  
Author(s):  
Fang Zhang ◽  
Jian Ping Chen ◽  
Chuan Dong Li ◽  
Yan Juan Wu

The main objective of power flow control for unified power flow controller (UPFC) is to increase the transmission capacity over the existing transmission corridor or line. This paper presents a practical engineering methodology of embedding the power flow control model of UPFC into the commercial software -- power system analysis software package (PSASP) based on its user program interface (UPI) function. In the proposed methodology, the interface currents of UPFC series side and UPFC shunt side between the UPFC device and the network are used to control the transmission line power flow and UPFC bus voltage, respectively. In UPFC series side, the current of UPFC series branch is calculated from the power target equation of the controlled line. In UPFC shunt side, the shunt reactive current of UPFC is used to control the bus voltage. Simulation results on a practical power system show that the proposed methodology can be efficiently applied to the engineering research and analysis of the real power grid with UPFC with good convergence and only one control parameter needed to be prescribed.


2015 ◽  
Vol 510 ◽  
pp. 48-53 ◽  
Author(s):  
Jian Xun Jin ◽  
Xiao Yuan Chen ◽  
Ronghai Qu ◽  
Hai Yang Fang ◽  
Ying Xin

Sign in / Sign up

Export Citation Format

Share Document