Thermal performance evaluation of an insulation system for cast resin power transformers

Author(s):  
L. Centurioni ◽  
G. Coletti ◽  
D. Tommasini
Author(s):  
Angélica Felicidade Guião Marcato Costa ◽  
João Alexandre Paschoalin Filho ◽  
Tatiana Tucunduva Philipi Cortese ◽  
Brenda Chaves Coelho Leite

This research aimed at comparing the thermal performance provided in experimental modules, one of which was performed with conventional cover, made of asbestos cement tiles; an another with green cover. The structure of the studied modules was executed using Light Steel Frame technique. As an experimental research, modules were built in a wide place, without the interference of shading. Instruments were installed in the inner part of the modules to measure the following data: air temperature, relative humidity. From the collected data, representative episodes have been chosen for the studies that aimed to compare the comfort provided by both modules, built with different roofs. As result, it was verified that the module with green roof had better performance than the module covered with asbestos cement tile in all selected episodes. The module covered with green roof maintained lower internal temperature variation throughout the days, indicating that the green roof has characteristic thermal insulation, reducing the heat flow from the roof.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4016
Author(s):  
Krzysztof Walczak ◽  
Jaroslaw Gielniak

HV bushings are an important part of the equipment of large power transformers, responsible for their many serious (including catastrophic) failures. Their proper exploitation needs to apply correct and reliable diagnostics, e.g., the use of dielectric response methods, that take into account their specific construction and working conditions. In this article, based on laboratory tests carried out on a real bushing, it has been shown that the significant temperature distribution within its core significantly affects the shape of the dielectric response of its insulation; therefore, the approach to its modeling should be changed. Hence, a new method for interpreting the results, using the so-called the 2XY model, is proposed. Subsequently, based on the measurements made on the insulators in operation, a new modeling method was verified. In conclusion, it can be stated that the 2XY model significantly improves the reliability of the dielectric response analysis, which should be confirmed in the future by tests on withdrawn and revised insulators.


2018 ◽  
Vol 172 ◽  
pp. 1867-1880 ◽  
Author(s):  
Syed Minhaj Saleem Kazmi ◽  
Muhammad Junaid Munir ◽  
Yu-Fei Wu ◽  
Asad Hanif ◽  
Indubhushan Patnaikuni

Solar Energy ◽  
2011 ◽  
Vol 85 (7) ◽  
pp. 1390-1398 ◽  
Author(s):  
Vishal R. Sardeshpande ◽  
Ajay G. Chandak ◽  
Indu R. Pillai

Sign in / Sign up

Export Citation Format

Share Document