Three-level inverter based shunt active power filter using generalized hysteresis current control method

Author(s):  
Shweta Gautam ◽  
Rajesh Gupta
Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


2014 ◽  
Vol 1030-1032 ◽  
pp. 1423-1431
Author(s):  
Jiang Zeng ◽  
Li Peng Huang

This paper presents a new hysteresis current control method for APF(active power filter) that can reduce switching losses effectively by means of adjusting the hysteresis band width according to the current size. On one hand, this method adjust the overall hysteresis band width according to the size of absolute norm of three-phase current that optimize the overall switching frequency, reduce the total switching losses effectively. On the other hand, it adjust hysteresis band width of each phase by comparing the output reference current to reduce the switching times which switching losses is larger, while increasing the switching frequency which switching losses is smaller, so as to maintain overall control precision. Computer simulation is conducted on an electromagnetic transient program. The results show that the new method can effectively reduce the switching losses under the same control accuracy and total switching frequency.


Sign in / Sign up

Export Citation Format

Share Document