Performance of a 2.8 kWp monocrystalline free-standing grid-connected photovoltaic system at SIRIM berhad

Author(s):  
Nur Adibah Jumien ◽  
Mohamad Zhafran Hussin ◽  
Ahmad Maliki Omar ◽  
Mohd Faisal Zulkapli
Author(s):  
VS Chandrika ◽  
M Mohamed Thalib ◽  
Alagar Karthick ◽  
Ravishankar Sathyamurthy ◽  
A Muthu Manokar ◽  
...  

Photovoltaic (PV) system efficiency depends on the geographical location and the orientation of the building. Until installing the building structures, the integration of the PV module must be evaluated with ventilation and without ventilation effects. This work optimises the performance of the 250 kWp grid-connected photovoltaic (GPV) for community buildings in the southern part of India. This simulation is carried out to evaluate the system efficiency of the GPV system under various ventilation conditions, such as free-standing PV (FSPV), building integrated photovoltaic ventilated (BIPV_V) and Building Integrated Photovoltaic without ventilation (BIPV). The PVsyst simulation tool is used to simulate and optimise the performance of the system with FSPV, BIPV and BIPV_V for the region of Chennai (13.2789° N, 80.2623° E), Tamilnadu, India. An annual system energy production is 446 MWh, 409 MWh and 428 MWh of FSPV, BIPV and BIPV_V system respectively. while electrical efficiency for the FSPV, BIPV_V, BIPV system is 15.45%. 15.25% and 14.75% respectively. Practical application: Integrating the grid connected photovoltaic system on the building reduces the energy consumption in the building. The integration of the PV on the roof or semi integrated on the roof is need to be investigated before installing on the buildings. The need for installation of the BIPV with ventilation is explored. This study will assist architects and wider community to design buildings roofs with GPV system which are more aesthetic and account for noise protection and thermal insulation in the region of equatorial climate zones.


Author(s):  
Adila Athirah Abdul Ghani ◽  
Mohamad Zhafran Hussin ◽  
Shahril Irwan Sulaiman ◽  
Mohd Faisal Zulkapli

Author(s):  
Muhammad Sani ◽  
Abdulmumin Sule

Metrological parameters plays significant role on the performance of solar panels in electrical power generation. To ascertain the extent to which ambient temperature, temperature of the panels, solar radiation were measured, recorded and analyzed at half-hour interval for five days, at the same period two solar panels were subjected to test, one being connected to a system of cooling leaving the other untouched. Measurement of both the output current and voltage were made from which the power output was calculated. The result shows that the power output was increasing as the solar radiation increased, which is clear indication that the entire photovoltaic process depend on the radiation intensity and environmental conditions. It was also observed that the efficiency of the solar panel with cooling system is slightly greater than that without cooling system. The efficiency and energy output of both solar panels were determined to be 15%, 13% and 477kWh, 449kWh respectively. The difference of 28kWh is not supposed to be neglected, because considering the difference of many days and many panels cannot be neglected. Also few approaches that have been proposed to reduce the effect of temperature on the solar photovoltaic system by choosing the appropriate configurations, by mounted on free standing frames, photovoltaic thermal collectors and building integrated photovoltaic arrays, respectively


Sign in / Sign up

Export Citation Format

Share Document