Noise reduction algorithm for full-waveform lidar signal

Author(s):  
Manuel Fabiao Dionizio ◽  
Ali Shamsoddini ◽  
John C. Trinder
Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 319
Author(s):  
Chan-Rok Park ◽  
Seong-Hyeon Kang ◽  
Young-Jin Lee

Recently, the total variation (TV) algorithm has been used for noise reduction distribution in degraded nuclear medicine images. To acquire positron emission tomography (PET) to correct the attenuation region in the PET/magnetic resonance (MR) system, the MR Dixon pulse sequence, which is based on controlled aliasing in parallel imaging, results from higher acceleration (CAIPI; MR-ACDixon-CAIPI) and generalized autocalibrating partially parallel acquisition (GRAPPA; MR-ACDixon-GRAPPA) algorithms are used. Therefore, this study aimed to evaluate the image performance of the TV noise reduction algorithm for PET/MR images using the Jaszczak phantom by injecting 18F radioisotopes with PET/MR, which is called mMR (Siemens, Germany), compared with conventional noise-reduction techniques such as Wiener and median filters. The contrast-to-noise (CNR) and coefficient of variation (COV) were used for quantitative analysis. Based on the results, PET images with the TV algorithm were improved by approximately 7.6% for CNR and decreased by approximately 20.0% for COV compared with conventional noise-reduction techniques. In particular, the image quality for the MR-ACDixon-CAIPI PET image was better than that of the MR-ACDixon-GRAPPA PET image. In conclusion, the TV noise-reduction algorithm is efficient for improving the PET image quality in PET/MR systems.


2021 ◽  
Vol 13 (4) ◽  
pp. 559
Author(s):  
Milto Miltiadou ◽  
Neill D. F. Campbell ◽  
Darren Cosker ◽  
Michael G. Grant

In this paper, we investigate the performance of six data structures for managing voxelised full-waveform airborne LiDAR data during 3D polygonal model creation. While full-waveform LiDAR data has been available for over a decade, extraction of peak points is the most widely used approach of interpreting them. The increased information stored within the waveform data makes interpretation and handling difficult. It is, therefore, important to research which data structures are more appropriate for storing and interpreting the data. In this paper, we investigate the performance of six data structures while voxelising and interpreting full-waveform LiDAR data for 3D polygonal model creation. The data structures are tested in terms of time efficiency and memory consumption during run-time and are the following: (1) 1D-Array that guarantees coherent memory allocation, (2) Voxel Hashing, which uses a hash table for storing the intensity values (3) Octree (4) Integral Volumes that allows finding the sum of any cuboid area in constant time, (5) Octree Max/Min, which is an upgraded octree and (6) Integral Octree, which is proposed here and it is an attempt to combine the benefits of octrees and Integral Volumes. In this paper, it is shown that Integral Volumes is the more time efficient data structure but it requires the most memory allocation. Furthermore, 1D-Array and Integral Volumes require the allocation of coherent space in memory including the empty voxels, while Voxel Hashing and the octree related data structures do not require to allocate memory for empty voxels. These data structures, therefore, and as shown in the test conducted, allocate less memory. To sum up, there is a need to investigate how the LiDAR data are stored in memory. Each tested data structure has different benefits and downsides; therefore, each application should be examined individually.


Radiology ◽  
2013 ◽  
Vol 269 (2) ◽  
pp. 553-560 ◽  
Author(s):  
Michael Söderman ◽  
Staffan Holmin ◽  
Tommy Andersson ◽  
Charlotta Palmgren ◽  
Draženko Babić ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document