Managing Inrush Current in A Variable Speed Drive Short Term Power Interruption Ride-Through Module

Author(s):  
Freeman Chiranga ◽  
Lesedi Masisi
Author(s):  
Fahmi Yunistyawan ◽  
Yunistyawan J Berchmans ◽  
Gembong Baskoro

This study implements the auto start control system on an electric motor 3 phase C4Feeding pump when the discharge pressure is low-low (4.3 kg /cm²). The C4 feeding pumpmotor was initially manually operated from the local control station, this was very ineffectiveand inefficient because it still relied on the field operator to operate the pump motor and whenthe plant was in normal operating it is very risk if the field operator late to operate motor then itwill impact to quality of the product, and if the delay time to operate motor is too long then planthave to shut down, therefore improvement is needed in the C4 feeding pump motor controlsystem. In this paper, various types of 3-phase motor control are explained which allow it to beapplied to the C4 feeding pump motor that are on-off, inverter, and variable speed drive andefficient selection of the three systems control of the motor. Software and hardware used in thisthesis work are DCS CENTUM VP Yokogawa.


Author(s):  
Sergei, Rybel’ ◽  
V. Kuninin ◽  
S. Gerasimov ◽  
A. Bakushin

Приведен опыт применения частотно-регулируемых электроприводов на насосных станциях ООО Водоканал г. Новокузнецка. Приводятся преимущества и недостатки данного технического устройства. Показано, что в настоящее время использование частотно-регулируемых приводов позволило снизить потребление электроэнергии более чем на 20, уменьшить затраты на ремонт и обслуживание, повысить срок службы электродвигателей, уменьшить величину пускового тока, снизить утечки воды и нагрузку на насосное оборудование и трубопроводную арматуру. Применение частотно-регулируемых электроприводов оправдало себя и в тех случаях, когда требуется регулирование параметров для обеспечения технологии (регулирование скорости, производительности и т. д.), приведение параметров оборудования к требуемым значениям без его замены (в расчете на увеличение загрузки оборудования до номинала в последующий период), компенсация суточной неравномерности потребления воды.The experience of using variable speed drives at the pumping stations operated by Vodokanal LLC in Novokuznetsk is presented. The advantages and disadvantages of this technical device are specified. It is demonstrated that currently, the use of variable speed drives provides for reducing the energy consumption by more than 20, reducing the repair and maintenance costs for improving the service life of electric motors for reducing inrush current, water leaks and the load on the pumping equipment and pipeline valving. The use of variable speed drives has paid off even in case where adjusting the parameters to ensure the technology (velocity, performance, etc.) bringing the equipment parameters to the required values without replacing it (in order to increase the equipment load to the nominal value for the subsequent period) compensating for daily irregularities in water consumption are required.


2010 ◽  
Vol 46 (8) ◽  
pp. 2892-2898 ◽  
Author(s):  
Vincent Ardon ◽  
Jérémie Aime ◽  
Olivier Chadebec ◽  
Edith Clavel ◽  
Jean-Michel Guichon ◽  
...  

Sign in / Sign up

Export Citation Format