Third Heart Sound Detection Using Wavelet Transform-Simplicity Filter

Author(s):  
D. Kumar ◽  
P. Carvalho ◽  
M. Antunes ◽  
J. Henriques ◽  
A. Sa e Melo ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4508
Author(s):  
Boyan Liu ◽  
Liuyang Han ◽  
Lyuming Pan ◽  
Hongzheng Li ◽  
Jingjing Zhao ◽  
...  

This research introduces an idea of producing both nanoscale and microscale pores in piezoelectric material, and combining the properties of the molecular β-phase dipoles in ferroelectric material and the space charge dipoles in order to increase the sensitivity of the sensor and modulate the response frequency bandwidth of the material. Based on this idea, a bi-nano-micro porous dual ferro-electret hybrid self-powered flexible heart sound detection sensor is proposed. Acid etching and electrospinning were the fabrication processes used to produce a piezoelectric film with nanoscale and microscale pores, and corona poling was used for air ionization to produce an electret effect. In this paper, the manufacturing process of the sensor is introduced, and the effect of the porous structure and corona poling on improving the performance of the sensor is discussed. The proposed flexible sensor has an equivalent piezoelectric coefficient d33 of 3312 pC/N, which is much larger than the piezoelectric coefficient of the common piezoelectric materials. Experiments were carried out to verify the function of the flexible sensor together with the SS17L heart sound sensor (BIOPAC, Goleta, CA, USA) as a reference. The test results demonstrated its practical application for wearable heart sound detection and the potential for heart disease detection. The proposed flexible sensor in this paper could realize batch production, and has the advantages of flexibility, low production cost and a short processing time compared with the existing heart sound detection sensors.


1955 ◽  
Vol 3 (1) ◽  
pp. 51-55 ◽  
Author(s):  
F. LOWELL DUNN ◽  
WILLIAM J. DICKERSON

2012 ◽  
Vol 20 (2) ◽  
pp. 307-315 ◽  
Author(s):  
Lígia Neres Matos ◽  
Tereza Cristina Felippe Guimarães ◽  
Marcos Antônio Gomes Brandão ◽  
Deyse Conceição Santoro

The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009. The results showed that 71.1% of the patients had decreased cardiac output (measured by cardiac index). The majority of the NANDA-International defining characteristics for DCO were more frequent in individuals with reduced cardiac index levels. The study emphasizes the odds ratio (OR) for increased Systemic Vascular Resistance of OR=4.533, of the third heart sound with OR=3.429 and the reduced ejection fraction with OR=2.850. By obtaining the predictive values for the defining characteristics the study identifies them as diagnostic indicators of decreased cardiac output.


2016 ◽  
Vol 63 (8) ◽  
pp. 1718-1727 ◽  
Author(s):  
Shovan Barma ◽  
Bo-Wei Chen ◽  
Wen Ji ◽  
Seungmin Rho ◽  
Chih-Hung Chou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document