heart sound
Recently Published Documents


TOTAL DOCUMENTS

1345
(FIVE YEARS 245)

H-INDEX

43
(FIVE YEARS 7)

2022 ◽  
Vol 32 (2) ◽  
pp. 1195-1205
Author(s):  
Zainab Arshad ◽  
Sohail Masood Bhatti ◽  
Huma Tauseef ◽  
Arfan Jaffar

2021 ◽  
Vol 47 (6) ◽  
pp. 514-528
Author(s):  
Doo-Seo Park ◽  
Min-Young Lee ◽  
Ki-hyun Kim ◽  
Hong-Chul Lee

Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 181
Author(s):  
Chen-Jun She ◽  
Xie-Feng Cheng ◽  
Kai Wang

In this paper, the graphic representation method is used to study the multiple characteristics of heart sounds from a resting state to a state of motion based on single- and four-channel heart-sound signals. Based on the concept of integration, we explore the representation method of heart sound and blood pressure during motion. To develop a single- and four-channel heart-sound collector, we propose new concepts such as a sound-direction vector of heart sound, a motion–response curve of heart sound, the difference value, and a state-change-trend diagram. Based on the acoustic principle, the reasons for the differences between multiple-channel heart-sound signals are analyzed. Through a comparative analysis of four-channel motion and resting-heart sounds, from a resting state to a state of motion, the maximum and minimum similarity distances in the corresponding state-change-trend graphs were found to be 0.0038 and 0.0006, respectively. In addition, we provide several characteristic parameters that are both sensitive (such as heart sound amplitude, blood pressure, systolic duration, and diastolic duration) and insensitive (such as sound-direction vector, state-change-trend diagram, and difference value) to motion, thus providing a new technique for the diverse analysis of heart sounds in motion.


2021 ◽  
Author(s):  
Valentina Roquemen-Echeverri ◽  
Peter G. Jacobs ◽  
Stephen Heitner ◽  
Peter M. Schulman ◽  
Bethany Wilson ◽  
...  

Author(s):  
Torib Hamzah Hamzah ◽  
Endang Dian Setioningsih ◽  
Sumber Sumber

One of the early examinations that is often done is to detect heart disease using a stethoscope. The electronic stethoscope consists of a membrane and tube from a conventional stethoscope coupled with a condenser microphone which is then connected to a computer. The purpose of this study is to analyze the comparison of two types of microcontrollers in the design of a portable electronic stethoscope equipped with a symptom detector. The research method used is instrumentation with 2 types of microcontrollers to design a heart sound detector. In processing the data to be displayed on the 16x2 Character LCD. Sending heart signal data for 60 seconds to produce BPM data which is processed using 2 different types of microcontrollers. The results of data collection on battery consumption of power usage on the AT mega 2560 resulted in an average saving of 0.11W. Therefore, it can be concluded that the two stethoscopes have a significant difference when compared, where the Arduino Mega 2560 is able to process data from heart signals faster than the AT mega 328P. The results of the research that have been carried out can be implemented using a system that strongly supports the needs when checking heart sound signals


2021 ◽  
pp. 809-817
Author(s):  
Luca Salvati ◽  
Nicola Cappetti ◽  
Matteo d’Amore ◽  
Anita Fiorentino ◽  
Arcangelo Pellegrino ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document