Finite element analysis of novel substrate design for high performance and cost reduction stacked die CSP

Author(s):  
W.R. Yueh ◽  
J.C.C. Lee ◽  
A.B.L. Wu ◽  
J.C.M. Chen
2013 ◽  
Vol 671-674 ◽  
pp. 1025-1028
Author(s):  
Dong Ku Shin ◽  
Kyungsik Kim

The ultimate compressive strengths of high performance steel (HPS) plate system stiffened longitudinally by closed stiffeners have been investigated by the nonlinear finite element analysis. Both conventional and high performance steels were considered in models following multi-linear strain hardening constitutive relationships. Initial geometric imperfections and residual stresses were also incorporated in the analysis. Numerical results have been compared to compressive strengths from Eurocode 3 EN 1993-1-5 and FHWA-TS-80-205. It has been found that although use of Eurocode 3 EN 1993-1-5 and FHWA-TS-80-205 may lead to highly conservative design strengths when very large column slenderness parameters are encountered


Author(s):  
Jifeng Wang ◽  
Qubo Li ◽  
Norbert Mu¨ller

A mechanical and optimal analyses procedure is developed to assess the stresses and deformations of Novel Wound Composite Axial-Impeller under loading conditions particular to centrifuge. This procedure is based on an analytical method and Finite Element Analysis (FEA, commercial software ANSYS) results. A low-cost, light-weight, high-performance, composite turbomachinery impeller from differently designed patterns will be evaluated. Such impellers can economically enable refrigeration plants using water as a refrigerant (R718). To create different complex patterns of impellers, MATLAB is used for creating the geometry of impellers, and CAD software UG is used to build three-dimensional impeller models. Available loading conditions are: radial body force due to high speed rotation about the cylindrical axis and fluid forces on each blade. Two-dimensional plane stress and three-dimensional stress finite element analysis are carried out using ANSYS to validate these analytical mechanical equations. The von Mises stress is investigated, and maximum stress and Tsai-Wu failure criteria are applied for composite material failure, and they generally show good agreement.


Author(s):  
Dazhong Wu ◽  
Xi Liu ◽  
Steve Hebert ◽  
Wolfgang Gentzsch ◽  
Janis Terpenny

Cloud computing is an innovative computing paradigm that can potentially bridge the gap between increasing computing demands in computer aided engineering (CAE) applications and limited scalability, flexibility, and agility in traditional computing paradigms. In light of the benefits of cloud computing, high performance computing (HPC) in the cloud has the potential to enable users to not only accelerate computationally expensive CAE simulations (e.g., finite element analysis), but also to reduce costs by utilizing on-demand and scalable cloud computing resources. The objective of this research is to evaluate the performance of running a large finite element simulation in a public cloud. Specifically, an experiment is performed to identify individual and interactive effects of several factors (e.g., CPU core count, memory size, solver computational rate, and input/output rate) on run time using statistical methods. Our experimental results have shown that the performance of HPC in the cloud is sufficient for the application of a large finite element analysis, and that run time can be optimized by properly selecting a configuration of CPU, memory, and interconnect.


2008 ◽  
Vol 120 (2) ◽  
pp. 69-79
Author(s):  
ADAM R. ASHLEY ◽  
FRANCIS J. LAROCK ◽  
CHARLES E. MANN

Author(s):  
Regina Furbino Villefort ◽  
Pedro Jacy Santos Diamantino ◽  
Sandra Lúcia Ventorin von Zeidler ◽  
Alexandre Luiz Souto Borges ◽  
Laís Regiane Silva-Concílio ◽  
...  

Abstract Objective Polymeric framework represent an innovative approach for implant-supported dental prostheses. However, the mechanical response of ultra-high performance polymers as frameworks for full-arch prostheses under the “all-on-four concept” remains unclear. The present study applied finite element analysis to examine the behavior of polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) prosthetic frameworks. Materials and Methods A three-dimensional maxillary model received four axially positioned morse-taper implants, over which a polymeric bar was simulated. The full-arch prosthesis was created from a previously reported database model, and the imported geometries were divided into a mesh composed of nodes and tetrahedral elements in the analysis software. The materials were assumed as isotropic, elastic, and homogeneous, and all contacts were considered bonded. A normal load (500 N magnitude) was applied at the occlusal surface of the first left molar after the model was fixed at the base of the cortical bone. The microstrain and von-Mises stress were selected as criteria for analysis. Results Similarities in the mechanical response were observed in both framework for the peri-implant tissue, as well as for stress generated in the implants (263–264 MPa) and abutments (274–273 MPa). The prosthetic screw and prosthetic base concentrated more stress with PEEK (211 and 58 MPa, respectively) than with PEKK (192 and 49 MPa), while the prosthetic framework showed the opposite behavior (59 MPa for PEEK and 67 MPa for PEKK). Conclusion The main differences related to the mechanical behavior of PEKK and PEEK frameworks for full-arch prostheses under the “all-on-four concept” were reflected in the prosthetic screw and the acrylic base. The superior shock absorbance of PEKK resulted in a lower stress concentration on the prosthetic screw and prosthetic base. This would clinically represent a lower fracture risk on the acrylic base and screw loosening. Conversely, lower stress concentration was observed on PEEK frameworks.


Sign in / Sign up

Export Citation Format

Share Document