An error current tracking control method of three-level active power filter

Author(s):  
Chenyu Zhang ◽  
Jun Mei ◽  
Jianyong Zheng
Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


2014 ◽  
Vol 556-562 ◽  
pp. 3585-3589
Author(s):  
Meng Qiong Wang ◽  
Chun Yu Xu

In view of the shortages time lag existing in traditional digital low-pass filter in Active Power Filter (Active Power Filter, APF), this paper proposes to adopt slipped-window integrator to realize low-pass filter in harmonic current detection.The current tracking control uses Space Vector Pulse Width Modulation method. Meanwhile, the repetitive predictor is applied so as to improve the real-time performance of the compensation current tracking control. Built a three-phase shunt active power filter simulation model in Matlab/Simulink environment and take experiment under the low pressure condition. The results show that slipped-window integrator and deadbeat current mothod can acquire good dynamic response performance as well as high precision.


Sign in / Sign up

Export Citation Format

Share Document