The Research on Plume Flow Field and Infrared Radiation Characteristic of Pulse Detonation Engine

Author(s):  
Hongxia Mao ◽  
Xingdong Bao ◽  
Jie Wu ◽  
Zheng Li
Author(s):  
Zhihong Zhang ◽  
Zhiqiang Li ◽  
Yunke Wu ◽  
Xingdong Bao

Shock focusing ignition techniques can avoid deflagration-to-detonation transition (DDT), which make pulse detonation engine (PDE) more efficient. Numerical simulations of an idealized pulse detonation engine consisting of axial inlet and circumferential inlet are presented in this paper. Using detailed hydrogen-air mixture chemical kinetic model, investigation on detonation direct initiation by shock focusing is done. Studies indicate that in initial static flow field, the regions of high temperature and pressure created by shock focusing can produce detonation at the condition of circumferential inlet Mach 2.4. The temperature and pressure of the focusing region is nearly 3000K and 6.3MPa. But in dynamic flow field, the high temperature and pressure created by shock wave focusing for an incident Mach number of 2.4 decrease to 1027K and 4.5MPa which cannot produce detonation. When the incident Mach number increases to 3.5, the transient temperature and pressure of the focusing region is nearly 3000K and 30MPa, which capable of initiating a detonation wave.


Author(s):  
Arun Prakash Raghupathy ◽  
Urmila Ghia ◽  
Karman Ghia

Pulse Detonation Engine (PDE) is considered to be the propulsion system of future air and space vehicles because of its low cost, light weight, and high performance. Hybrid PDE is a relatively new concept where a turbine is integrated with a PDE. This hybrid system is expected to operate under fuel-rich conditions during take-off (stoichiometric), and fuel-lean (φ = 0.44) conditions during cruise. Hence, the objective of the present study is to simulate the external flow field of a stand alone PDE system and study its variation during the above mentioned operating conditions. In order to study Hybrid PDE systems, the underlying concept of the working of a stand alone PDE, namely, detonation, has to be simulated first. For this purpose, the one-dimensional reactive Euler equations are solved. Since a propagating detonation wave is the result of chemical reactions in a very small region, flow adaptive grids are used for the one dimensional detonation simulations. The global chemical mechanisms employed predicted all the detonation quantities for both stoichiometric and lean mixture of hydrogen-air with the least error. The results from the global chemical mechanism for both mixtures are used in the two-dimensional PDE simulations. Analyses of the axial pressure and temperature distribution in the external flow field show the nature of the blowdown process and its variation for different operating conditions. Flow exergy analysis shows that there is 25% loss in available work when a turbine is placed at one tube length away from the exit of the PDE. One of the important outcomes of this study is the information that can guide in the placement of the turbine downstream of the PDE to achieve lower blowdown time.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Gui-yang Xu ◽  
Chun-guang Wang ◽  
Yan-fang Zhu ◽  
Hong-yan Li ◽  
Lun-kun Gong ◽  
...  

AbstractThe experiment system of pulse detonation engine is set up to investigate on influence of diameter on detonation acoustic characteristic. The research of detonation acoustic characteristic of pulse detonation engine for four different diameters in different angles is carried out. Results from the test show that as the PDE diameter increasing, there are increases in amplitudes of impact noise in all angles, and the growth rate of amplitude of impact noise in the 90° direction is generally greater than that in the 0° direction. The smaller PDE diameter is, the distance of most obvious directivity at 0° turning to most obvious directivity at 30° is shorter. When the distance is shorter, such as 200 mm, the duration of detonation acoustic is increasing with the increase of PDE diameter, however, when the distance is longer, such as 3000 mm, it is just the opposite. The maximum duration of detonation acoustic is appeared in 3000 mm under 30 mm PDE diameter which reaches to 1.44 ms.


2001 ◽  
Author(s):  
E. Wintenberger ◽  
J. Austin ◽  
M. Cooper ◽  
S. Jackson ◽  
J. Shepherd

2021 ◽  
Vol 2125 (1) ◽  
pp. 012006
Author(s):  
Nan Wu ◽  
Chengpo Mu ◽  
Yang He ◽  
Huan Liu ◽  
Taiye Liu

Abstract In order to study the infrared radiation (IR) characteristics of rocket engine plume in the mid infrared band, a calculation model for IR transfer of rocket engine plume was built. The flow field data are calculated by software FLUENT. Based on HITRAN database, the IR characteristic parameters are calculated after spectral line correction. The Line of Sight (LoS) is used to solve the radiation characteristics in the plume flow field, and the IR characteristics distribution of the plume in the mid infrared band is obtained, which agree well with the results from open literature. The method has the advantages of simple model, less parameters and fast calculation speed in this paper.


Sign in / Sign up

Export Citation Format

Share Document