Novel fiber for low-loss mid-infrared transmission

Author(s):  
Betty Meng Zhang ◽  
Perry Ping Shum ◽  
Wu Yuan ◽  
Xueping Cheng
1992 ◽  
Vol 46 (7) ◽  
pp. 1194-1197 ◽  
Author(s):  
S. J. Saggese ◽  
J. A. Harrington ◽  
G. H. Sigel ◽  
R. Altkorn ◽  
R. Haidle

The fabrication and temperature-dependent mid-infrared transmission characteristics of gold-on-nickel, silver-on-nickel, silica, and sapphire hollow lightpipes are discussed. The metal tubes offer improved low-temperature transmission and more versatile fabrication methods than do conventional FT-IR lightpipes. The dielectric tubes offer extremely low loss in certain spectral regions, outstanding high-temperature performance, and, in some cases, sufficiently low cost to be considered disposable.


2015 ◽  
Vol 23 (7) ◽  
pp. 8261 ◽  
Author(s):  
L. Carletti ◽  
P. Ma ◽  
Y. Yu ◽  
B. Luther-Davies ◽  
D. Hudson ◽  
...  

Author(s):  
Joan Manel Ramirez ◽  
Qiankun Liu ◽  
Vladyslav Vakarin ◽  
Jacopo Frigerio ◽  
Andrea Ballabio ◽  
...  
Keyword(s):  
Low Loss ◽  

2016 ◽  
Vol 41 (5) ◽  
pp. 946 ◽  
Author(s):  
Ke Yin ◽  
Bin Zhang ◽  
Jinmei Yao ◽  
Linyong Yang ◽  
Shengping Chen ◽  
...  
Keyword(s):  
Low Loss ◽  

2000 ◽  
Vol 54 (3) ◽  
pp. 450-455 ◽  
Author(s):  
Stephen R. Lowry ◽  
Jim Hyatt ◽  
William J. McCarthy

A major concern with the use of near-infrared (NIR) spectroscopy in many QA/QC laboratories is the need for a simple reliable method of verifying the wavelength accuracy of the instrument. This requirement is particularly important in near-infrared spectroscopy because of the heavy reliance on sophisticated statistical vector analysis techniques to extract the desired information from the spectra. These techniques require precise alignment of the data points between the vectors corresponding to the standard and sample spectra. The National Institute of Standards and Technology (NIST) offers a Standard Reference Material (SRM 1921) for the verification and calibration of mid-infrared spectrometers in the transmittance mode. This standard consists of a 38 μm-thick film of polystyrene plastic. While SRM 1921 works well as a mid-infrared standard, a thicker sample is required for use as a routine standard in the near-infrared spectral region. The general acceptance and proven reliability of polystyrene as a standard reference material make it a very good candidate for a cost-effective NIR standard that could be offered as an internal reference for every instrument. In this paper we discuss a number of the parameters in a Fourier transform (FT)-NIR instrument that can affect wavelength accuracy. We also report a number of experiments designed to determine the effects of resolution, sample position, and optics on the wavelength accuracy of the system. In almost all cases the spectral reproducibility was better than one wavenumber of the values extrapolated from the NIST reference material. This finding suggests that a thicker sample of polystyrene plastic that has been validated with the SRM 1921 standard would make a cost-effective reference material for verifying wavelength accuracy in a medium-resolution FT-NIR spectrometer.


2019 ◽  
Vol 9 (11) ◽  
pp. 2351 ◽  
Author(s):  
Da Teng ◽  
Kai Wang ◽  
Zhe Li ◽  
Yongzhe Zhao ◽  
Gao Zhao ◽  
...  

Graphene has been recently proposed as a promising alternative to support surface plasmons with its superior performances in terahertz and mid-infrared range. Here, we propose a graphene-coated elliptical nanowire (GCENW) structure for subwavelength terahertz waveguiding. The mode properties and their dependence on frequency, nanowire size, permittivity and chemical potential of graphene are studied in detail by using a finite element method, they are also compared with the graphene-coated circular nanowires (GCCNWs). Results showed that the ratio of the long and short axes (b/a) of the elliptical nanowire had significant influence on mode properties, they also showed that a propagation length over 200 μm and a normalized mode area of approximately 10−4~10−3 could be obtained. Increasing b/a could simultaneously achieve both long propagation length and very small full width at half maximum (FWHM) of the focal spots. When b/a = 10, a pair of focal spots about 40 nm could be obtained. Results also showed that the GCENW had a better waveguiding performance when compared with the corresponding GCCNWs. The manipulation of Terahertz (THz) waves at a subwavelength scale using graphene plasmon (GP) may lead to applications in tunable THz components, imaging, and nanophotonics.


2020 ◽  
Vol 104 (2) ◽  
pp. 833-850 ◽  
Author(s):  
Pengfei Wang ◽  
Alson Kwun Leung Ng ◽  
Alastair Dowler ◽  
Heike Ebendorff‐Heidepriem

Sign in / Sign up

Export Citation Format

Share Document