Analysis and reduction of power losses in PV converters for grid connection to low-voltage three-phase three-wire systems

Author(s):  
Ryosuke Amma ◽  
Hideaki Fujita
2021 ◽  
Vol 3 (2) ◽  
pp. 395-408
Author(s):  
Karthikeyan Nainar ◽  
Florin Iov

Power-distribution grids consist of assets such as transformers, cables, and switches, of which the proper utilization is essential for the provision of a secure and reliable power supply to end customers. Distribution-system operators (DSOs) are responsible for the operation and maintenance of these assets. Due to the increased use of renewable sources such as wind and solar, grid assets are prone to operation conditions outside safe boundaries, such as overloading, large voltage unbalance, and a rise in voltage. At present, distribution grids are poorly monitored by DSOs, and the above-mentioned problems may thereby go unnoticed until the failure of a critical asset occurs. The deployment of smart meters in distribution grids has enabled measurements of grid variables such as power, current, and voltage. However, their measurements are used only for billing purposes, and not for monitoring and improving the operating condition of distribution grids. In this paper, a state-estimation algorithm is proposed that utilizes smart-meter data for offline analysis, and estimates the loading of grid assets and power losses. Single- and three-phase state-estimation algorithms are compared through simulation studies on a real-life low-voltage distribution grid using measured smart-meter data. The three-phase state-estimation algorithm based on the nonlinear weighted least-squares method was found to be more accurate in estimating cable loading and line power losses. The proposed method is useful for DSOs to analyze power flows in their distribution grids and take necessary actions such as grid upgrades or the rerouting of power flows.


Author(s):  
Emad Hussen Sadiq ◽  
Rakan Khalil Antar ◽  
Safer Taib Ahmed

Nowadays, the electrical system is more complicated duet to the continuous growing. Power losses is the biggest challenges for distribution network operators. There are several causes for technical losses. Losses caused by unbalanced phase current are one of the main reasons which can be minimized by small investment through dedicating a technical line staff. As a result of connecting many single loads to three phase four wire power supplies, the current flowing in each phase will be unequal and accordingly there will be a current flowing in the neutral wire. Unbalancing currents in phases can lead to increase the conductor temperature and accordingly the conductor resistance is higher which contribute to increase the power losses. Loss reduction can lead to enormous utility saving. Besides, it increases system capacity and save more money which can be used later for future planted system. This study concentrated on the amount of copper losses in distribution networks as a result of unequal loading of the three phases four wires network. The distribution network is more efficient and more economic assuming that the right procedure is applied to balance the distribution system and achieve the required calculations which require a little investment.


2021 ◽  
Vol 60 (3) ◽  
pp. 79-91
Author(s):  
Dmitry Tugay ◽  
Olexandr Shkurpela ◽  
Valentyn Akymov ◽  
Ivan Kostenko ◽  
Oleksandr Plakhtii

A new model for decomposition of the total power losses, which includes four components is proposed. Each of the components of the proposed model has a certain physical meaning due to the nature of electromagnetic processes in a three-phase four-wire system. Definitions to describe each of the proposed components are formulated. It is shown that each of supplementary components of the total loss power is proportional to the minimum possible loss power and to the square of the RMS value of the power, which is caused by its occurrence in three-phase four-wire power supply system, and it is inversely proportional to the mean square of the net power loss. The synthesized Matlab-model for verification of the four-component structure of power losses showed a high degree of its adequacy. The proposed model allows us to rethink the description of power losses in three-phase AC circuits and can be used in specialized measuring instruments for electrical networks monitoring. Using the information obtained in the monitoring process, it is possible to plan technical measures to reduce losses of electrical energy in the power supply system, as well as to estimate the capital costs of these measures.


2017 ◽  
Vol 2017 (3) ◽  
pp. 65-70
Author(s):  
A.F. Zharkin ◽  
◽  
V.A. Novskyi ◽  
N.N. Kaplychnyi ◽  
A.V. Kozlov ◽  
...  